EASY PROGRAM MODE OVERVIEW (Using a GEM-RP3DGTL Keypad)

 

 
ENTERING THE EASY KEYPAD PROGRAM MODE  

1   

Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if 

 programmed and press 

A

 

2   

Press NO (

F

) repeatedly until function "

17

" (Activate Program Mode) is displayed.   

      

NOTE:

 If you pass "

17

"  you can scroll back by pressing 

B

.   

3   

Press YES (

E

) to enter the Dealer Program Mode.

 

Use the following guide to answer the Easy Program Mode questions which will quickly allow you to create a custom 
default program.  Press 

A

 to set cursor, NEXT (

E

) to go forwards, PRIOR (

F

) to go backwards, 

D

 to 

save and 

C

 twice to exit the Easy Program Mode. 

 

ANSWERING A QUESTION IN THE EASY PROGRAM MODE

 

The Easy Program Mode the questions will be in the form of a 2-digit number flashing in the digital display.   
Pressing 

A

 

will set the cursor into the next field to answer the question. 

Using this book as a guide, enter the appropriate data in response to each question and then press 

D

 

to save. 

If no additional programming is necessary for the question, press NEXT (

E

) to go to the next question. 

 

REVIEWING THE DATA ENTRY IN THE EASY PROGRAM MODE

 

The data entered in response to an Easy Program Mode question may be reviewed before saving.   

After entering the data before pressing 

D

 

to save, 

A

 may be pressed until the 2 digit question number 

appears flashing in the display again. 

 

Pressing 

A

 will step through all the fields of the question for review and will then result in the 2 digit question 

number flashing in the display again.   

 

!

If the data is correct, press 

D

 

to save. 

!

If the data is not correct, press 

A

 to set the cursor into the next field and again enter the appropriate 

data.   

 

Note:  

The contents of an Easy Program Mode question may be reviewed after the initial programming of the control, 

with the exception of the questions which are marked (Appears for New Panel Only).  These questions set up the 
basic structure of the control panel program (Number of zones in an area, etc.) and cannot be viewed or altered once 
set.   
 

EXITING THE DEALER PROGRAM MODE

  

If in the Easy Program Mode, press 

C

 to enter the Direct Address Program Mode.  Press 

C

 once again to 

end all programming and resume normal keypad operation. 
 

RESETTING THE CONTROL PANEL TO FACTORY DEFAULT 

If necessary, the control panel can be returned to the factory default and be re-programmed from scratch. 

 

For the GEM-P816 and GEM-P1632, enter the Direct Address program mode, go to location 1198 and press 

D

.

 

       

(

A1198

D

 

Содержание Gemini GEM-RP3DGTL

Страница 1: ...ng examples in this manual reflect the GEM RP3DGTL keypad connected to a GEM P1632 panel When used with the GEM P816 panels the program ming is identical except for the panel limits such as Areas 1 Zo...

Страница 2: ...ndby Note Subtract keypad current from combined auxiliary current of the control panel Operating Temperature 0 C to 49 C Storage Temperature 20 C to 85 C Power Requirements 12VDC 45mA supplied by pane...

Страница 3: ...addition the keypad may be configured to disable touchpad backlight and entry sounder Keypads are configured by the proper selection of jumpers Refer to the label on the keypad circuit board for jumpe...

Страница 4: ...ROGRAM MODE The data entered in response to an Easy Program Mode question may be reviewed before saving After entering the data before pressing D to save A may be pressed until the 2 digit question nu...

Страница 5: ...e doubling is not desired press NO F NOTE Answer NO for GEM P816 Fire Zones in Area 1 Appears for New Panel Only Press the A button and then directly enter the zone number of any zones which are to be...

Страница 6: ...Station Receiver 1 Telephone Number Press the A button and using the number buttons directly enter telephone number of up to 16 digits including prefix if necessary for receiver 1 NOTE Central Station...

Страница 7: ...e as described above and press D to save Similarly to cancel a code blank out each number of the code press D to save DATA ENTRY CS RECEIVER 1 FORMAT blank Ademco Slow Silent Knight Slow 2 Radionics F...

Страница 8: ...ely 1 Enter the Enroll mode as described in step 2 above 2 Enter Zone 11 3 Open the loops of points 1 and 2 4 Install the transmitter battery The keypad will beep 3 times to indicate that three points...

Страница 9: ...fob to a zone program the keyfob as you would a transmitter entering the keyfob s ID code check sum and point number at the appropriate zone The Quick Method is not allowed The zone may be hardwired t...

Страница 10: ...as shown in the adjacent diagram ACCESSING DIRECT ADDRESS PROGRAM MODE 1 Enter the Dealer Security Code default 456789 for a new panel or enter your custom Dealer Program Code if programmed 2 Press A...

Страница 11: ...11 MOUNTING TEMPLATE 4 3 8 2 3 8 KEYPAD BUS WIRES TAMPER DO NOT CUT OR DRILL WALL...

Страница 12: ...er person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of N...

Отзывы: