Although a fire alarm system may be of a 

reliable and state-of- the-art design, neither it 
nor its peripheral detection devices can offer 
guaranteed protection against fire. Any such 
equipment may fail to warn for a variety of 
reasons: 

Control panels, communicators, dialers, 

smoke detectors, and many other sensing 
devices will not work without power. Battery- 
operated devices will not work without batteries, 
with dead batteries, or with improperly-installed 
batteries. Devices powered solely by AC will 
not work if their power source is cut off for any 
reason. 

Fires often cause a failure of electrical 

power. If the system does not contain a working 
battery backup power supply, and if the 
electrical circuit feeding the devices is cut or is 
not providing power for any reason, the system 
will not detect heat or smoke or provide any 
warning of a possible fire. 

Telephone lines needed to transmit alarm 

signals to a central monitoring station may be 
out of service.  

Smoke detectors, though highly effective 

in reducing fire deaths, may not activate or 

provide early-enough warning for a variety of 
reasons: (a) they may not sense fires that start 
where smoke cannot reach them, such as in 
chimneys, walls, roofs, behind closed doors, 
etc.; (b) they may not sense a fire on a different 
level of the residence or building; (c) they have 
sensing limitations; no smoke detector can 
sense every kind of fire every time. 

Thermostatic heat detectors do not 

always detect fires because the fire may be a 
slow smoldering low-heat type (producing 
smoke); because they may not be near the fire; 
or because the heat of the fire may bypass 
them. These detectors will not detect oxygen 
levels, smoke, toxic gases, or flames. 
Therefore, they may only be used as part of a 
comprehensive fire-detection system in 
conjunction with other devices. Under no 
circumstances should thermostatic heat 
detectors be relied upon as the sole measure to 
ensure fire safety. 

Alarm warning devices such as sirens, 

bells, or horns may not alert someone behind a 
closed or partially-opened door. Warning 
devices located on one level are less likely to 
alert those on a different level. Even those who 
are awake may not hear the warning if the 

alarm is obscured by noise from a stereo, radio, 
air conditioner, or other appliance, or by 
passing traffic, etc. Alarm warning devices, 
however loud, may fail to warn the hearing 
impaired. 

Alarm products, as all electrical devices, 

are subject to component failure. Even though 
the equipment is designed for many years of 
trouble-free performance,  electronic 
components could fail at any time. 

Above are some of the reasons that fire 

alarm equipment could fail. The most common 
cause of an alarm system not functioning when 
a fire occurs is inadequate testing and 
maintenance. The system should be tested at 
least weekly to ensure that all the equipment is 
working properly. 

While an alarm system may make one 

eligible for lower insurance rates, it is not a 
substitute for insurance. Homeowners, property 
owners, and renters are therefore urged to 
maintain adequate insurance coverage of life 
and property. 

LIMITATIONS OF FIRE ALARM WARNING SYSTEM 

Содержание Gemini GEM-K3DGTL

Страница 1: ...M K3DGTL KEYPAD NAPCO 2006 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 INTERIOR BYPASS FIRE TBL SYS TBL CHIME 96 INTERIOR BYPASS FIRE TBL SYS TBL CHIME 96 P Q G U NEXT Y...

Страница 2: ...ion and state of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests Note The K Series GEM K3DGTL keypad is c...

Страница 3: ...S 21 PROGRAMMING USER CODES 22 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 27 TROUBLESHOOTING 31 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL __________________ CENTRAL STATION ________...

Страница 4: ...TORS 1 2 3 4 5 6 7 12 8 9 10 11 13 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U INTERIOR BYPASS FIRE TBL SYS TBL CHIME 96 INTERIOR BYPASS FIRE TBL SYS TBL CHIME 9...

Страница 5: ...splays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ENTER Button Entry key Causes the entered code or selected function to be executed ST...

Страница 6: ...eave the premises Leave through the exit door before the exit time expires Priority Arming If you attempt to arm the system with a faulted Zone a 3 second tone will sound at the keypad and P will disp...

Страница 7: ...d while others remain disarmed Manager s Mode The Manager s Mode allows the user to arm disarm other areas in a partitioned system To arm a different area 1 Press the numerical key representing the ot...

Страница 8: ...rotection When retiring for the evening after all family members are home you can cancel the entry delay on the Entry Zone s To arm with instant protection press and hold P for 2 seconds after arming...

Страница 9: ...n of a police emergency Police Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows a user to exit the premises wh...

Страница 10: ...call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code and press U After the system is disarmed the window will continue to display the number s of the zone s violated...

Страница 11: ...ition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad within about 10 seconds Fire Zone Trouble The system is constantly monitoring the Fire...

Страница 12: ...with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not s...

Страница 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Страница 15: ...rmal operating mode if no activity is detected for longer than one minute 1 Display Zone Status Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed on...

Страница 16: ...l sound a tone at the keypad when the programmed zone is opened while disarmed To deactivate the Chime Mode execute Function 7 once again Note The Chime Mode is disabled while armed 8 Activate Watch M...

Страница 17: ...reset press C to clear the display enter the Function Menu scroll to Reset Sensor Watch Failure and press U If you cannot correct the problem call for service 11 Start Exit Time Optional Start Exit T...

Страница 18: ...hours To Delay Arm the system With Function 16 in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by U At the end of this 1 4 hour Delay Arming period the siren will sound...

Страница 19: ...press NEXT P to proceed to the next group or PRIOR Q to scroll back to the previous group Press C when done Relay Group 01 ____________________________________ Relay Group 02 ________________________...

Страница 20: ...lled during the Abort De lay or cancelled after the report is sent and an acknowledgement of the can cellation is received a C will appear in the keypad window Regular Burglary Non 24 Hour Zone report...

Страница 21: ...all for service Function 11 Start Exit Time may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was...

Страница 22: ...ming Reprogramming a User Code 1 Press R followed by the the 2 digits of the user number to be programmed Example for User 4 enter 04 2 Press R followed by the new User Code Note User Codes may be up...

Страница 23: ...code 5 Press C to exit the Program Mode Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer Whil...

Страница 24: ...arming Turning the system on or off as follows Arming Code P or Q Disarming Code U Arming Stay Arming with interior zones bypassed allowing free move ment within the premises Arming Away Arming with A...

Страница 25: ...ce emergency Partitioned System A system that has been subdivided into two or more up to eight independent subsystems areas Pre Alarm Warning A keypad sounder alert of an impending alarm This option i...

Страница 26: ...when the system is armed Burglary Zone Detects intrusion Day Zone A zone that will cause a visual and audible indication at the keypad if it is in trouble while disarmed Exit Entry Follower Zone Provi...

Страница 27: ...uble Condition Action E 01 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call i...

Страница 28: ...B The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with t...

Страница 29: ...service E 15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E 16 NN Wireless Receiver Jam A problem has been detected with...

Страница 30: ...rglary Bus Failure Call installing company for service E 24 Service Message The system is in need of a preventive maintenance service call E 27 00 Printer Failure Call installing company for service E...

Страница 31: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 27 The Fire Alarm is sounding and...

Страница 32: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...

Отзывы: