F I R E   P R O T E C T I O N  

Although a fire alarm system may be of a 

reliable and state-of- the-art design, neither it 
nor its peripheral detection devices can offer 
guaranteed protection against fire. Any such 
equipment may fail to warn for a variety of 
reasons: 

Control panels, communicators, dialers, 

smoke detectors, and many other sensing 
devices will not work without power. Battery- 
operated devices will not work without 
batteries, with dead batteries, or with 
improperly-installed batteries. Devices 
powered solely by AC will not work if their 
power source is cut off for any reason. 

Fires often cause a failure of electrical 

power. If the system does not contain a 
working battery backup power supply, and if 
the electrical circuit feeding the devices is cut 
or is not providing power for any reason, the 
system will not detect heat or smoke or 
provide any warning of a possible fire. 

Telephone lines needed to transmit 

alarm signals to a central monitoring station 
may be out of service.  

Smoke detectors, though highly effective 

in reducing fire deaths, may not activate or 
provide early-enough warning for a variety of 

reasons: (a) they may not sense fires that 
start where smoke cannot reach them, such 
as in chimneys, walls, roofs, behind closed 
doors, etc.; (b) they may not sense a fire on a 
different level of the residence or building; (c) 
they have sensing limitations; no smoke 
detector can sense every kind of fire every 
time. 

Thermostatic heat detectors do not 

always detect fires because the fire may be a 
slow smoldering low-heat type (producing 
smoke); because they may not be near the 
fire; or because the heat of the fire may 
bypass them. These detectors will not detect 
oxygen levels, smoke, toxic gases, or flames. 
Therefore, they may only be used as part of 
a comprehensive fire-detection system in 
conjunction with other devices. Under no 
circumstances should thermostatic heat 
detectors be relied upon as the sole measure 
to ensure fire safety. 

Alarm warning devices such as sirens, 

bells, or horns may not alert someone behind 
a closed or partially-opened door. Warning 
devices located on one level are less likely to 
alert those on a different level. Even those 
who are awake may not hear the warning if 
the alarm is obscured by noise from a stereo, 

radio, air conditioner, or other appliance, or 
by passing traffic, etc. Alarm warning 
devices, however loud, may fail to warn the 
hearing impaired. 

Alarm products, as all electrical devices, 

are subject to component failure. Even 
though the equipment is designed for many 
years of trouble-free performance, electronic 
components could fail at any time. 

Above are some of the reasons that fire 

alarm equipment could fail. The most 
common cause of an alarm system not 
functioning when a fire occurs is inadequate 
testing and maintenance. The system should 
be tested at least weekly to ensure that all 
the equipment is working properly. 

While an alarm system may make one 

eligible for lower insurance rates, it is not a 
substitute for insurance. Homeowners, 
property owners, and renters are therefore 
urged to maintain adequate insurance 
coverage of life and property. 

LIMITATIONS OF FIRE ALARM WARNING SYSTEM 

Содержание Gemini GEM-K1CA

Страница 1: ...OPERATING GUIDE for your GEM K1CA KEYPAD NAPCO 2005 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U SYSTEM READY 09 15 05 12 05 AM NEXT YES PRIOR NO AREA OI279D 5 0...

Страница 2: ...f readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION IMPORTANT TEST YOUR SYSTEM WEEKLY Test you...

Страница 3: ...ELL PHONE STYLE 24 SETTING THE DATE AND TIME 26 KEYPAD MESSAGES 27 GLOSSARY 30 SYSTEM TROUBLE ERROR CODES 33 TROUBLESHOOTING 38 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS U FOR SERVICE CALL _______...

Страница 4: ...4 KEYPAD CONTROLS INDICATORS ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U SYSTEM ARMED 09 01 05 12 00 AM 1 2 3 4 5 6 7 12 8 9 10 11...

Страница 5: ...tors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ENTER Button Entry key Causes the entered code or selected function to be executed STAY Button 1 Bypasses all Interior Zones simultaneous...

Страница 6: ...ining in 10 second steps Note If you enter a wrong code the keypad will display INVALID ENTRY TRY AGAIN 3 Leave the premises Leave through the exit door before exit time expires Priority Arming If you...

Страница 7: ...arm disarm a different area 1 Press the numerical key representing the other area number 2 Press Gfollowed by U The keypad will now provide status and control of that area 3 Enter your User Code foll...

Страница 8: ...instant protection press and hold down P for 2 seconds at any time after the system is armed When armed with Instant Protection opening the entry door will cause an immediate alarm When arming with In...

Страница 9: ...awaking the family Press U to activate Easy Exit on your system GEM P3200 GEM P9600 V20 or greater GEM P816 P1632 V9A or greater Emergency Buttons Only available if programmed The Blue Emergency Butto...

Страница 10: ...s disarmed the window will continue to display ALARM followed by the zone s violated 2 To reset the display note the zones violated then press C Ambush Optional Your Ambush Code Type is TYPE 1 Prefix...

Страница 11: ...a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad w...

Страница 12: ...th all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not sto...

Страница 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Страница 15: ...d for longer than one minute Display Zone Faults Displays the zone number of zones that are not secured If needed press the NEXT and PRIOR Buttons as displayed on screen to scroll faulted zones requir...

Страница 16: ...ys trouble conditions that have been detected on the Fire Zone s Use NEXT P and PRIOR Q to scroll zones required for GEM P3200 9600 panels GEM P816 1632 panels will auto scroll Activate Chime The Chim...

Страница 17: ...he Function Menu scroll to RESET SENSOR MSG and press U If you cannot correct the problem call for service Note This function available with GEM P9600 and GEM P3200 control panels only Start Exit Time...

Страница 18: ...4 hours To Delay Arm the system With the function TO ARM IN 1 4 HRS displayed in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by U At the end of this 1 4 hour Delay Armi...

Страница 19: ...o the next group or PRIOR Q to scroll back to the previous group Press C when done Note This function available with GEM P9600 and GEM P3200 control panels only Relay Group 01 ________________________...

Страница 20: ...to 45 sec onds at your option by consulting with your installer Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report...

Страница 21: ...tral station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for service Function 11 Start Exit Time may the...

Страница 22: ...when U is pressed Repeat Steps 1 through 3 for each User Code to be programmed Erasing a User Code 1 Enter the digits of the user number to be erased followed by RR 2 Press G0 to erase each digit of...

Страница 23: ...panel enter all three digits of the user number 4 Press U to save the code Note Duplicate Codes are not allowed therefore a duplicate Code entered in the LCD Window will erase when U is pressed Press...

Страница 24: ...he next zone or to any other zone Move the cursor to the displayed zone number i e 01 using R and B Change the zone number using keys 0 through 9 Enter two digits for the zone number after entering th...

Страница 25: ...UENCE 1 ABC1 1 abc1 2 DEF2 2 def2 3 GHI3 3 ghi3 4 JKL4 4 jkl4 5 MNO5 5 mno5 6 PQR6 6 pqr6 7 STU7 7 stu7 8 VWX8 8 vwx8 9 YZ90 9 yz90 0 SPACE 0 Reserved CELL PHONE STYLE ENTRY Use R and B buttons to mov...

Страница 26: ...enter 07 29 00 2 Press U to save the Date Programming the Time After entering in the Date press NEXT P for the Time Entry screen 1 At the Enter Time screen simply punch in the correct time using the n...

Страница 27: ...dicates Service Code active I indicates arming with Instant protection Entry delay in progress XXX shows entry time remaining in seconds System armed With the GEM P3200 9600 panels the I indicates arm...

Страница 28: ...ess C to silence sounder Evacuate premises or correct cause of alarm For partitioned systems only Code not valid for area Wrong code entered or Easy Bypass function not enabled In Manager s Mode Armin...

Страница 29: ...receives an acknowledgment from the central station of the cancellation of the alarm signal Indicates problem s detected on system See examples below and SYSTEM TROUBLE ERROR CODES for a complete list...

Страница 30: ...by its own keypad or by a keypad of a different Area through Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing U Battery Backup power source in...

Страница 31: ...ort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless sys tems only Weak transmit...

Страница 32: ...elay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including spac...

Страница 33: ...System Trouble Condition Action E01 00 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker oth...

Страница 34: ...equired for the GEM PIR and GEM GB The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warn...

Страница 35: ...e Fail ure NN Relay Board Number Call installing company for service E15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E1...

Страница 36: ...the sensor is able to detect activity in the area clear any obstacles which may be blocking the sensor from detecting activity Press C to clear the display and then use the Function Menu to Reset Sens...

Страница 37: ...re zone indicated Call installing company for service GEM P1632 and GEM P816 panels only E51 00 Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for service E58 00...

Страница 38: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 33 The Fire Alarm is sounding and...

Страница 39: ...39 NOTES...

Страница 40: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...

Отзывы: