G L O S S AR Y  

Exit/Entry Delays

 - Separate delays 

that let you exit and enter your 
premises without setting off an alarm 
when the system is armed. 

 

INTERIOR Button

 - Bypasses 

Interior Zones on arming (see Zones - 
Interior Zones). 

 

Instant Protection

 - Arming without 

entry delay using the 

F

 button 

while remaining on the premises. 

 

Keypad

 - Puts control-panel 

functions at your fingertips. It can be 
mounted anywhere in your premises. 

 

Manager's Mode

 - In a partitioned 

system, a low-security operating 
mode that allows arming by area. 

 

Panic Buttons 

- Blue buttons on 

the keypad (

G

 and 

7

8

 or 

9

). If enabled, 

pressing 

G

 together with 

7

8

 or 

9

 will alert the central 

station of a fire, auxiliary, or police 
emergency. 

 

Partitioned System

 - A system that 

has been subdivided into two or more 
(up to eight) independent subsystems 
(areas). 

 

Pre-Alarm Warning.

 - A keypad 

sounder alert of an impending alarm. 
This option is programmable by zone 
for the same duration as that 
programmed for Abort Delay (see 
Abort Delay). 

 

Report 

- A transmission to a central 

station notifying of a change in the 
status of the system (alarm, trouble, 
low battery, etc.). 

 

RF Low Battery

 - (Wireless sys-  

tems only) Weak transmitter battery. 

 

RF Check In

 - (Wireless systems 

only) Periodic test report from 
transmitter (if a report is not received 
on time, a supervisory-failure system 

trouble will result). 

 

Ringback 

- A beep after arming 

verifying the central-station's receipt of 
a closing report. 

 

Service Code

 - A code intended for 

temporary use. 

 

Sounder

 - A local warning device at 

each keypad to alert that (a) entry 
delay has started; (b) an attempt was 
made to arm with a zone in trouble; 
(c) a Day-Zone condition exists (see 
Zones: Day Zone); (d) 10 seconds exit 
time remaining; (e) invalid code 
entered; or (f) central station 
acknowledged arming (see Ringback). 

 

System Trouble 

- A problem (low 

battery, power failure, etc.) detected in 
the system. 

 

Trouble

 - A zone fault; an open 

door, window, or other problem that 
may prevent arming. 

Содержание Gemini GEM-DXRP1

Страница 1: ...1 OPERATING GUIDE for your GEM DXRP1 KEYPAD NAPCO 2006 OI322 6 06 SYSTEM READY 10 01 06 12 09 AM...

Страница 2: ...of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION IMPORTANT TEST YOUR SYSTEM WEEKLY Test yo...

Страница 3: ...ELL PHONE STYLE 24 SETTING THE DATE AND TIME 26 KEYPAD MESSAGES 27 GLOSSARY 30 SYSTEM TROUBLE ERROR CODES 33 TROUBLESHOOTING 38 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL _______...

Страница 4: ...4 KEYPAD CONTROLS INDICATORS 1 2 3 4 5 6 7 12 9 10 11 8...

Страница 5: ...ystem troubles displays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or selected function...

Страница 6: ...ing in 10 second steps Note If you enter a wrong code the keypad will display INVALID ENTRY TRY AGAIN 3 Leave the premises Leave through the exit door before exit time expires Priority Arming If you a...

Страница 7: ...arm disarm a different area 1 Press the numerical key representing the other area number 2 Press Gfollowed by J The keypad will now provide status and control of that area 3 Enter your User Code foll...

Страница 8: ...to automatically adjust the interior protection accordingly If you arm the system and remain in the house all Interior Zones are automatically bypassed The keypad will display BYPASSED indicating tha...

Страница 9: ...it on your system GEM P3200 GEM P9600 V11D or less GEM P1632 V8G or less Press D to activate Easy Exit on your system GEM P3200 GEM P9600 V20 or greater GEM P816 P1632 V9A or greater Emergency Buttons...

Страница 10: ...stem is disarmed the window will continue to display ALARM followed by the zone s violated 2 To reset the display note the zones violated then press C Ambush Optional Your Ambush Code Type is TYPE 1 P...

Страница 11: ...a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad w...

Страница 12: ...th all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not sto...

Страница 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Страница 15: ...s detected for longer than one minute Display Zone Faults Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed on screen to scroll faulted zones require...

Страница 16: ...n the Fire Zone s Use NEXT E and PRIOR F to scroll zones required for GEM P3200 9600 panels GEM P816 1632 1664 panels will auto scroll Activate Chime The Chime Mode will sound a tone at the keypad whe...

Страница 17: ...the Function Menu scroll to RESET SENSOR MSG and press D If you cannot correct the problem call for service Note This function available with GEM P9600 and GEM P3200 control panels only Start Exit Ti...

Страница 18: ...o 4 hours To Delay Arm the system With the function TO ARM IN 1 4 HRS displayed in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by J At the end of this 1 4 hour Delay Ar...

Страница 19: ...to the next group or PRIOR F to scroll back to the previous group Press C when done Note This function available with GEM P9600 and GEM P3200 control panels only Relay Group 01 _______________________...

Страница 20: ...to 45 sec onds at your option by consulting with your installer Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report...

Страница 21: ...central station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for service Function 11 Start Exit Time may...

Страница 22: ...peat Steps 1 through 3 for each User Code to be programmed Erasing a User Code 1 Enter the digits of the user number to be erased followed by AA 2 Press G0 to erase each digit of the User Code and the...

Страница 23: ...e code Note Duplicate Codes are not allowed therefore a duplicate Code entered in the LCD Window will erase when D is pressed Press C to exit the Program Mode Notes If the system contains more than on...

Страница 24: ...he next zone or to any other zone Move the cursor to the displayed zone number i e 01 using A and B Change the zone number using keys 0 through 9 Enter two digits for the zone number after entering th...

Страница 25: ...NO5 5 mno5 6 PQR6 6 pqr6 7 STU7 7 stu7 8 VWX8 8 vwx8 9 YZ90 9 yz90 0 SPACE 0 Reserved CELL PHONE STYLE ENTRY 1 ABC1 2 DEF2 3 GHI3 4 JKL4 7 STU7 8 VWX8 9 YZ90 6 PQR6 5 MNO5 0 Use A and B buttons to mov...

Страница 26: ...00 enter 07 29 00 2 Press D to save the Date Programming the Time After entering in the Date press NEXT E for the Time Entry screen 1 At the Enter Time screen simply punch in the correct time using th...

Страница 27: ...in seconds If displayed S indicates Service Code active I indicates arming with Instant protection Entry delay in progress XXX denotes entry time remaining in seconds System armed With the GEM P3200 9...

Страница 28: ...ress C to silence sounder Evacuate premises or correct cause of alarm For partitioned systems only Code not valid for area Wrong code entered or Easy Bypass function not enabled In Global Arming Mode...

Страница 29: ...receives an acknowledgment from the central station of the cancellation of the alarm signal Indicates problem s detected on system See examples below and SYSTEM TROUBLE ERROR CODES for a complete list...

Страница 30: ...by its own keypad or by a keypad of a different Area through Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing J Battery Backup power source in...

Страница 31: ...larm This option is programmable by zone for the same duration as that programmed for Abort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the...

Страница 32: ...rior devices Entry delay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises us...

Страница 33: ...System Trouble Condition Action E01 00 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker oth...

Страница 34: ...equired for the GEM PIR and GEM GB The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warn...

Страница 35: ...e Fail ure NN Relay Board Number Call installing company for service E15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E1...

Страница 36: ...le to detect activity in the area clear any obstacles which may be blocking the sensor from detecting activity Press C to clear the display and then use the Function Menu to Reset Sensor Watch Failure...

Страница 37: ...Fire zone indicated Call installing company for service GEM P1632 GEM P816 and GEM P1664 panels only E51 00 Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for se...

Страница 38: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 33 The Fire Alarm is sounding and...

Страница 39: ...39 NOTES...

Страница 40: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...

Отзывы: