NAPCO GEMC-BSLC-PIR Скачать руководство пользователя страница 2

 
 
 
 
 
 
 
 
 
 
 
 
 
 
If you are protecting a typical room area which may include 
small pets or rodents (no larger than 20 lbs. total weight), 
the factory installed wide angle lens can be used.  If pets will 
be present locate the detector as high as possible (7 ft. 
minimum) and avoid placement that would allow the pets to 
get within 6 ft. of the detector.  It may be necessary to mask 
a zone with the supplied material if a staircase is close to the 
detector and directly in a zone.  It is also possible to adjust 
beams laterally by sliding the lens and retainer horizontally 
within its stops.   
 

Pet-Alley Lens (LENS817) 

(Not evaluated by UL) 

For larger pets use a Pet-Alley Lens (LENS817).  This lens 
provides the same pattern and coverage as the standard 
Wide-Angle lens, but there are no lower zones.  This creates 
an unprotected "Pet Alley" in which a larger pet can freely 
move about.  The detector should be mounted at 5 to 6 ft. 
with the board mounting height index set to 6 ft. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Barrier Lens (LENS818) 

(Not evaluated by UL)

 

For hallways, aisles or corridors use the Barrier lens, 
sometimes referred to as a curtain lens (LENS818), will 
provide the best solution.  This lens stacks the elements to 
form an efficient and effective wall that will detect anyone 
crossing it while ignoring motion on either side of the 
detector.  The detector has a maximum range of 50 ft. with 
this lens.  
 
 
 
 
 
 
 
 

Long Range Lens (LENS840) 

(Not evaluated by UL) 

For longer range coverage the Long Range Lens 
(LENS840) will provide up to 100 feet of range with a single 
pair of beams.Complete coverage pattern is included with 
the lens. 

 

MOUNTING  

First, use a screw driver to carefully lift the lens cover from 
the housing.  Second, remove the circuit board from the 
housing by removing the screw in the center of the board.  

Note: 

the screw is attached to the circuit board and will not 

separate when removed.  Third, determine the wire entry 
points on the housing.  The housing provides four possible 
wire entry points, two for surface wiring and two for hidden 
wiring.  Determine which entry is most convenient and 
punch out or remove the thin plastic section.  Fourth, mount 
the housing to the wall.  There are three mounting options to 
choose from depending on the desired location: flat wall 
mounting, corner mounting or using the swivel bracket 
(SVL2) for ceiling and wall mounting where it is 
advantageous to tilt or aim the unit along a wall.  

Note: 

using two units on swivel brackets mounted side by side it is 
possible to cover almost 180 degrees when mounted on a 
flat wall.  If using the swivel bracket refer to the instructions 
with the bracket.  For wall or corner mounting simply hold 
the case in the desired location and using the supplied 
screws push through the appropriate thin wall mounting 
screw holes and attach the unit with two or four screws.  

Note: 

Do not over tighten the screws as this can distort the 

case and compromise the air seal of the unit, because not 
all walls are flat and all corners are square.  Reinstall the 
circuit board and proceed to wire the detector.  
 

WIRING & TERMINAL DESCRIPTIONS 

Refer to the wiring diagram and terminal descriptions, 
connect the appropriate wire to the corresponding terminal.  
When you have finished wiring the terminals seal the 
opening around the wire entry hole and any other unused 
holes with the supplied sealer. 

 
Power (Terminals 1 [S] & 2 [S]): 

Connect to the [S] and [S] 

terminals on the GEMC-BSLC. 

 

Side View: Pet-Alley Lens (LENS817) used for larger pets 

 

5-6 ft. 

pet undected 

Large Pet Avoidance 

50 ft. 

Top View: Barrier Lens (LENS818) used for hallways 

 

50 ft. 

GEMC-BSLC-PIR Circuit Board Detail 

 

S

              

 

6FT 

 

 
 

 
 

 
 

 
 

 

12FT 

HT  LT  

SEN  

 

TEMPERATURE 
SENSOR 

MOUNTING HEIGHT 
SCALE (ALIGN WITH 
INDEX IN CASE) 

HEIGHT LOCK 
SCREW 

WALK TEST LED 

LED 

DISABLE 

LOOK DOWN 

LENS 

INFRARED 

SENSOR 

REMOVE JUMPER 

TO DISABLE LED 

TAMPER SWITCH 

SLC BUS 

ENABLE TROUBLE 

OUTPUT ON HIGH 

TEMPERATURE 

ENABLE TROUBLE 
OUTPUT ON LOW 
TEMPERATURE 

SENSITIVITY 

OFF = NORMAL 
ON = HIGH 

WIRE ENTRY 

KNOCKOUT 

Side View: Standard Lens (LENS100) used for small pets 

 

pet less than 20 lbs. only 

7 ft. 
min. 

avoid pet activity within 6 ft. of detector 

Small Pet Avoidance 

30 ft. 

Отзывы: