For  "Series Zone Doubling & Loop Supervision" Configuration: 

1.   Do not program NO EOLR (by zone) 
2.   Program Day Zone on Open (by zone) 
3.   Enable Zone Supervision (global) 
 

SERIES ZONE AND LOOP SUPERVISION CONFIGURATION (1 EZM-4 ZONES) 

Loop supervision with 
one contact using a 
2.2K across the con-
tact and a 2.2K EOL 
resistor, as shown in 
the illustration at right: 

2.2K 

2.

2K

 

2.

2K

 

2.2K 

2.2K 

2.

2K

 

2.

2K

 

2.2K 

17 

16 

15 

14 

13 

12 

11 

9  10 

(+) 

(–) 

Configuration = 1 EZM

For "Series Zone and Loop Supervision 
Configuration": 

1.    Do not program NO EOLR (by zone) 
2.    Program Day Zone on Open (by zone) 
3.    Enable Zone Supervision (global) 
 

SERIES ZONE AND LOOP SUPERVISION CONFIGURATION (2 EZM-8 ZONES) 

Loop supervision with 
one contact using a 
2.2K across the con-
tact and a 2.2K EOL 
resistor, as shown in 
the illustration at right: 

"Series Zone and Loop Supervision"  Zone Operation 

 

Armed (Set) or 24H 

Disarmed (unset) 

1) Series N/C device 

active 

Alarm 

Zone Fault 

2) Parallel N/O device 

active 

N/A 

N/A 

3) Zone Short 

Alarm and Day Zone 

TBL* 

Day Zone TBL* and Zone 

Fault 

4) Zone Open 

Alarm and Day Zone 

TBL* 

Day Zone TBL* and Zone 

Fault 

* Day Zone TBL generates a pulsing keypad sounder, 
“DAY ZONE TROUBLE” on LCD and SYS TBL Icon on 
when disarmed.  A System Trouble E98-00 will remain on 
the system until all day zone troubles have been reset. 

Configuration = 2 EZM
(Default Setting)

2.2K 

2.

2K

 

2.

2K

 

2.2K 

2.2K 

2.

2K

 

2.

2K

 

2.2K 

17 

16 

15 

14 

13 

12 

11 

9  10 

(+) 

(–) 

2.2K 

2.

2K

 

2.

2K

 

2.2K 

2.2K 

2.

2K

 

2.

2K

 

2.2K 

SERIES ZONE DOUBLING

TM

 AND LOOP SUPERVISION (3 EZM-12 ZONES) 

Each loop has 2 zone resistors (2.2K and 4.7K) for each zone, 
and a third 2.2K EOLR provides loop supervision (see diagram).  
In loop 1, the 2.2K contact resistor ("Z1") represents the primary 
zone and the 4.7K resistor ("Z9") represents the secondary zone.  
In the disarmed state, a loop open or shorted (day zone trouble) 
will display at the keypad and is reported to the central station (if 
selected).  The loop supervision function will continue to operate 
regardless of the state of the zone contacts on that loop, even if a 
loop is bypassed.  In the armed state, the loop supervision func-
tion will report and display a system trouble notification.  When the 
door/window contact is actuated by a magnet, the contact is 
closed (shorting out the zone resistor).  When the contact is open, 
the contact places the zone resistor in the circuit.  The panel can 
detect the following loop conditions, as follows: 

A.    Loop completely open or shorted:  Day Zone Trouble  
B.    All Contacts closed:  Loop Resistance=2.2K (Normal) 
C.    All Contacts Open:  Loop Resistance=9.1K 
D.    Contact 1 ("Z1") open:  Loop Resistance= 4.4K 
E.    Contact 2 ("Z9") open:  Loop Resistance= 6.9K 

To activate programming addresses for Zone Doubling and Loop 
Supervision, refer to the GEM-P1664 Programming Instructions. 

SERIES ZONE DOUBLING

TM

 AND LOOP SUPERVISION (4 EZM-16 ZONES) 

2.2K 

4.

7K

 

2.

2K

 

Z9

 

Z1

 

2.2K 

4.

7K

 

2.

2K

 

Z10

 

Z2

 

2.2K 

4.

7K

 

2.

2K

 

Z11
 

Z3

 

2.2K 

4.

7K

 

2.

2K

 

Z12

 

Z4

 

2.2K 

4.

7K

 

2.

2K

 

Z13
 

Z5

 

2.2K 

4.

7K

 

2.

2K

 

Z14

 

Z6

 

6  7  8 

17 

16 

15 

14 

13 

12 

11 

9  10 

2.2K 

4.

7K

 

2.

2K

 

Z15
 

Z7

 

2.2K 

4.

7K

 

2.

2K

 

Z16

 

Z8

 

(+)  (–) 

Configuration = 4 EZM

"Series Zone Doubling and Loop Supervision" Zone Operation 

 

Armed (Set) or 24H 

Disarmed (unset) 

1) Series N/C device active 

Alarm 

Zone Fault 

2) Parallel N/O device 

active 

N/A 

N/A 

3) Zone Short 

Alarm and Day Zone TBL* 

Day Zone TBL* and Zone 

Fault 

4) Zone Open 

Alarm and Day Zone TBL* 

Day Zone TBL* and Zone 

Fault 

* Day Zone TBL generates a pulsing keypad sounder, “DAY ZONE TROU-
BLE” on LCD and SYS TBL Icon on when disarmed.  A System Trouble E98-
00 will remain on the system until all day zone troubles have been reset. 

2.2K 

4.

7K

 

2.

2K

 

Z9

 

Z1

 

2.2K 

4.

7K

 

2.

2K

 

Z10

 

Z2

 

2.2K 

4.

7K

 

2.

2K

 

Z11
 

Z3

 

2.2K 

4.

7K

 

2.

2K

 

Z12

 

Z4

 

6  7  8 

17 

16 

15 

14 

13 

12 

11 

9  10 

(+)  (–) 

2.2K 

2.

2K

 

2.

2K

 

2.2K 

2.2K 

2.

2K

 

2.

2K

 

2.2K 

g)

Configuration = 3 EZM

Z5

 

Z6

 

Z7

 

Z8

 

Отзывы: