F-8 Control Panel Features:
•
6 Programmable Hardwire or
Wireless Zones, 2 Wireless
Zones* and 2-Wire Fire
(*Note:
These 2 zones are hardwired when
system includes a second Touchpad)
•
Supports all Gemini
Transmitters using Gemini
GEMRECVXP8 Wireless
Receiver
•
50 Event Log
•
No exit/entry countdowns, eliminates user-caused
false alarms when they most frequently occur.
•
To prevent false alarms when arming, during a
pre-arm period, the system looks for motion, in all
its motion sensors and touchpad PIR sensors, and
if detected, automatically converts to “Armed
STAY”, (solely turning on perimeter protection).
•
Programmable Telco Line-Cut and Bell-Cut
Supervision
•
Fuseless, maintenance-free operation
•
PCD-WINDOWS PC Programmable (Version
5.2 or higher) including PC-Preset unattended
downloading
•
UL listed
Communicator Features:
•
All Major Communicator Formats including, Point
ID, Ademco Slow, Radionics Slow/Fast, Silent
Knight Fast, Universal High Speed, 4/2, etc.
•
Double Reporting & Backup Reporting, including
pager format
•
Programmable Telco Line Cut & Bell Cut
Supervision
•
Restoral reporting: AC, Battery, Trouble, Fire
•
Reporting: Low Battery, Opening/closing,
conditional closing; system, zone report, tamper,
wireless smoke supervisory and low battery
Downloadable
Control Panel
System Specifications (with Wireless Lock
Interface):
•
Max. number of code-free, key-controlled doors, 4.
•
Max. number of Freedom Touchpads (any): 2
•
Each of 2 Freedom Touchpads can monitor 2 door locks
each, each using F-2D Wireless Lock 2nd Door Interface kit.
(Note: Transmission range of F-2D Lock Interface to touch-
pad’s built-in receiver is approximately 600’ open air).
•
Operating temperature: 0-49 degrees C (32-120 F)
•
Input power: 16.5 VAC plug-in 20VA transformer
•
Loop voltage: 5 Volts
•
Loop current: 1.1 mA
•
Loop resistance: 300 ohms per zone (max.)
•
Alarm output: Burg: 12 VDC, 2A (max.)
Fire: 12 VDC, 65 mA
•
Combined standby current: 500 mA residential
burglary (4 hour standby); 500 mA residential fire
(4 hour standby); 120 mA residential fire (24 hour
standby)
•
Current limiting: Burg/fire: 2.25A
•
Output: 2A, max.-burg; 125mA, max.-fire
•
Maximum charging current: 165mA
•
Housing: 8-3/8” x 10-1/4” x 3” (H x W x D)
•
Required battery: 12V 4AH rechargeable
(For Hardwired Freedom F-8 specs. see WI1430)
• Allows users to arm/disarm their system and
monitor deadbolt locked/unlocked status.
• Includes 1-button disarm/silence in night or
stay modes.
• Night mode, turns on all interior devices,
except PIR built into bedroom touchpad.
• No lock required in bedroom
Bedroom Touchpad provides easy
control from the comfort of the
bedroom.
Bedroom
Touchpad