F64 Hybrid Control:
One 8 to 64 zone panel to standardize on
Flexible F64 System Features:
• 8 Hardwire or wireless zones on board, programmable by area
• Expandable up to 64 zones (through EZM multiplex modules
and/or 4-zones built-in at each touchpad
• Supports up to 4 areas
• 400 event log; viewable at the touchpad
• F64 supports up to 7 touchpads (F64CODE-K1VPS and -K1V
as well as Freedom Code-free F64TP models; these may be
intermixed in the system, too. See WI1640B).
• Supports 2-wire fire (2 zones) & 4-wire fire
• Supports Gemini Transmitters using 8, 6, 96 point Gemini
Receivers
• Supports 3 outputs; up to 16 external outputs (RB/RM3008)
• Programmable Telco line-cut and bell-cut
• Reports alarms, restores and troubles by zone.
• One interior zone group.
• Two chimes by zone; programmable duration.
• 2 PGM outputs.
• PCD-WINDOWS (v5.6.1 or higher) - Familiar Napco PC
programming and PC-preset
• All major communicator formats: SIA, Point ID, 4/2, etc.
• Fuseless, maintenance-free operation
• Three 20-digit telephone numbers.
• Backup reporting; Double reporting; Split reporting.
• 64 User Codes with opening/closing -reporting by user.
• AC failure reporting with programmable report delay.
• Supervised telephone line with 60 second delay.
• Pager capability
• SIA CP-01 features
F64 System Specifications:
Input Power: 16.5-18.0 VAC via Class 2 Plug-In 20VA, 40VA or
50VA Transformer
Loop Current: 3mA; 5mA for 2-wire smoke-detector zones
Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-
detector zones
Alarm Voltage Output: 1;
Programmable Negative Outputs: 2
Auxiliary Power Output: 11.7-12.5 VDC
Remote Power Output: 12 VDC regulated
Combined Standby Current
- See WI1501
UL Listings & Compliances:
Household Burglar Alarm System Units: UL1023
Household Fire Warning System Units: UL985
Security Industry Association (SIA) False Alarm Reduction
Standard CP-01
F64 Coded Kit & Accessories
Ordering information:
F-64CODEKIT1
Complete F64 Coded Kit: Coded talking
touchpad w/built-in siren, PIR, downloadable 8 to 64 zone
hybrid control, plug-in transformer.
F-64CODE-K1VPS
Additional coded multifunction talking
touchpad with built-in siren & PIR and smart display, for use with
KIT1 or 2.
F-64CODEKIT2
, Kit as above, where talking touchpad does not
include built in Siren and PIR/occupany sensor.
F-64CODE-K1VS
Additional coded talking touchpad (NO built-
in siren & NO PIR, for use with KIT2 or 1.
F-64 System options:
PCD-WINDOWS
(v5.6.1 or higher) Quickloader Downloader
Software with PC Preset.
F-64TP/TAB
Freedom Codefree Multifunction Touchpad w/ PIR
& Siren plus deadbolt lock interface.(May be intermixed with
F64CODED Touchpads in F64 System (see WI1640B).
GEM-TEMP64
Indoor or outdoor temperature sensor displays
temperature on touchpad display
GEM-EZM4/8
4 to 8 zone EZM multiplex expansion module
WI1501
Control Panel Installation Instructions
WI1502
Control Panel Programming Instructions
WI1629B
Installation Addendum
WI1640B
F64 Touchpad Applications & Configuration
Instruction
OI318
Freedom System Users Guide
TRF11
Transformer, 16.5Vac/40VA, Class 2
TRF14
Transformer, 16.5Vac/50VA, Class 2
RBAT4
4Ah 12VA Battery
ALL GEMINI WIRELESS DEVICES
See back
the power of one panel
One F64 partitionable control panel to standardize on with 8-64-zones
of power and flexibility for every application. Plus proven Gemini
wireless support, familiar Napco Quickloader software & now a choice of
multifunction talking touchpads technologies.
F64 Control Panel:
64 zones with Gemini crystal-controlled wireless support