Napa Carlyle ETW38FL Скачать руководство пользователя страница 2

ETW12FL, ETW14FL, ETW38FL 

Rev. 02/11/13

THIS INSTRUCTION MANUAL CONTAINS IMPORTANT SAFETY INFORMATION. 
READ THIS INSTRUCTION MANUAL CAREFULLY AND UNDERSTAND ALL INFORMATION BEFORE OPERATING THIS TOOL.

•  To safeguard torque accuracy avoid keeping tool set at high loads  for long periods of time.    

 

 

When finished reset back to zero.

•   Do not operate without eye or hand protection.
•   Keep body working stance balanced and firm. Do not overreach when  operating the tool. 
•   Keep fingers and hands away from pinch point region of this tool at all times.
•   Failure to heed these warnings may result in serious or fatal  personal injury and/or property damage.
•  Do not force tool beyond its rated capacity. Use of a "cheater bar" or leverage multipliers will result in an  
 

inaccurate reading and can possibly damage the wrench.

 Use of unapproved accessories could push the  

 

unit beyond its rated capacity and will void your warranty.

•  Do not use torque wrench to loosen fasteners.
•  The wrench should be sent in for calibration once every year or every 5,000 cycles for re-calibration.
•  The wrench should be cleaned and stored properly after every use. 

Do not submerge this unit in any fluid.

• 

Wrenches should be re-calibrated if dropped or accidentally mishandled.

•  The torque wrench should be "exercised" a minimum of three times at 100% of full scale before use.  
•  Do not remove any labels. Replace damaged labels.
•  Communications port is for use by authorized service center technicians only.

FAILURE TO OBSERVE THESE WARNINGS COULD RESULT IN INJURY

WARNING - FOLLOW THESE RULES FOR SAFE OPERATION!

WARRANTY

SPECIFICATIONS

DIGITAL TORQUE WRENCH - LIMITED 1 YEAR WARRANTY 

Carlyle  Professional  Hand  Tools  warrants  to  the  original  purchaser  that  the  company’s  digital  torque  wrenches  are  free  from 

defects  in  material  or  workmanship  during  the  1  year  warranty  period.  We  will  repair  or  replace  any  digital

 

torque wrench which fails to give satisfactory service due to defective workmanship or materials (excluding calibration) for 1 year 

from the date of original purchase. (Calibration is only covered by this warranty for each new unused torque wrench out of box.)  

Repairs or replacements are warranted as described above for the duration of the original warranty period. Products must be 

returned with proof of purchase, freight prepaid, to the warranty service center listed below.
This warranty excludes torque wrenches which have been subjected to abnormal use, accident, neglect, or lack of maintenance.  

Any modification, disassembly of this wrench or repair by an unauthorized service center will void the warranty. This warranty gives 

you specific rights. You may also have other rights which vary from state to state.
The  foregoing  obligation  is  Carlyle  Professional  Hand  Tools  sole  liability  under  this  or  any  implied  warranty  and  under  no 

circumstances shall Carlyle Professional Hand Tools be liable for any incidental or consequential damages.

Note:

 Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or  

exclusion may not apply to you.

For Warranty Service and Recalibration/Certification Services, contact:
  

Torque Wrench Repair Facility

 

 

  315 

Hawkins Rd.

 

  Travelers Rest, SC 29690

 

  Phone:  866.496.8423 • Fax: 864.834.6651

IMPORTANT SHIPPING NOTE:

  To avoid shipping damage when you return your torque wrench for repair, please enclose your 

Carlyle Torque Wrench in its original molded case (if included with your model) and package securely so that it is resistant to 
impact shock while in transit.

Notes from Page 1:
*1:   The accuracy of the readout is guaranteed from 20% to 100% 

of maximum range + /- 1 increment. The torque accuracy is a 
typical value. Calibration point is at the middle line of the five 
anti-slip lines on the rubber handle. To maintain the 

 

accuracy  of  the  torque  wrench,  calibration  should  be 
performed  once  a  year  or  every  5,000  cycles,  whichever 

comes first. Accuracy is based on the zero degree of offset 
from perpendicular drive. 

*2:   Use two AA batteries

Содержание Carlyle ETW38FL

Страница 1: ...kg cm Head Type Flex Ratchet Gear teeth 36 Audible Alarm Yes Buttons 4 LED Indicator 12 LED s Batteries 2 AA Battery Life Continuous Operation 2 110 Hrs Battery Life Standby 2 1 Year Operating Temper...

Страница 2: ...o give satisfactory service due to defective workmanship or materials excluding calibration for 1 year from the date of original purchase Calibration is only covered by this warranty for each new unus...

Страница 3: ...LABLE AS RSBC Battery Cap RSETW12FLCS Blow Mold Case for ETW12FL RSETW14FLCS Blow Mold Case for ETW14FL RSETW38FLCS Blow Mold Case for ETW38FL RS4HRP Head Repair Kit for ETW12FL RS2HRP Head Repair Kit...

Страница 4: ...KIT CONT Step 2 Insert the pawl spring into the handle spring hole See Fig 2 Step 3 Place the steel ball on top of the pawl spring See Fig 3 Step 4 Insert the pawl with the square hole facing inward a...

Страница 5: ...of the switch and the bottom of the pawl See Fig 5 are both pointing in the same direction Then fasten with the switch screw Step 6 Insert the driver into the ratchet head aligning the teeth on the d...

Страница 6: ...e after being idle for 5 minutes to save power Press to wake from Sleep mode SET UP RESETTING THE WRENCH If the wrench does not function normally Press at the same time to reset the wrench 1 Power On...

Страница 7: ...he button POWER ON RESET SELECTING UNITS OF MEASURE The torque wrench displays 4 different units of measure 1 Newton meters N m 2 Inch Pounds in lb 3 Foot Pounds ft lb 4 Kilogram Centimeter kg cm Pres...

Страница 8: ...operator can begin to apply load to the wrench As a load is gradually applied to the wrench the display will show the operator the amount of torque on the fastener When 90 of the desired torque is rea...

Страница 9: ...2 Press the button a third time cLrA appears in the display This clears all stored Peak Hold values from memory 3 Press the button a fourth time ConU appears in the display allowing you to continue to...

Страница 10: ...eza Trinquete flexible Dientes de engranaje 36 Alarma audible S Botones de control 4 Indicador DEL 12 l mparas DEL Bater as 2 AA Operaci n de vida continua de la bater a 2 110 horas Vida de la bater a...

Страница 11: ...n servicio satisfactorio debido a una mano de obra o materiales defectuosos excluyendo el calibrado por un a o a parte de la fecha original de compra El calibrado s lo est cubierto bajo esta garant a...

Страница 12: ...n alistado bajo la declaraci n de garant a para todas las reparaciones dentro y fuera de garant a Equipo de reparaci n de cabeza LAS PARTES DE REPUESTO DISPONIBLES COMO RSBC Tapa de bater a RSETW12FLC...

Страница 13: ...trinquete en el agujero del resorte del mango Ver la fig 2 Paso 3 Coloque la bola de acero en la parte superior del resorte del trinquete Ver la fig 3 Paso 4 Inserte el trinquete con el agujero cuadra...

Страница 14: ...nferior del trinquete ver la fig 5 los dos est n apunt ndose en la misma direcci n Luego sujete con el tornillo del interruptor Paso 6 Inserte el conductor en la cabeza del trinquete alineando los die...

Страница 15: ...parado por 5 minutos con el fin de ahorrar potencia Oprima para sacar del modo suspendido MONTAJE REAJUSTE DE LA LLAVE Si la llave no funciona de manera normal oprima a la vez para reajustar la llave...

Страница 16: ...DE MEDICI N El torqu metro muestra 4 unidades diferentes de medici n 1 Metros Newton N m 2 Libras pulgada in lb 3 Libras pie ft lb 4 Kilogramo cent metro kg cm Al oprimir el bot n se permite ciclar se...

Страница 17: ...memoria a usarse el operador puede comenzar a aplicar carga al torqu metro En la medida que se aplique una carga gradualmente al torqu metro el despliegue le mostrar al operador la cantidad de torsi n...

Страница 18: ...el bot n una tercera vez cLrA aparece en el despliegue Este borra todos los valores de retenci n de picos almancenados en la memoria 3 Oprima el bot n una cuarta vez ConU aparece en el despliegue per...