background image

3.

Power on the WineStation.

a.

Plug the power cord (provided) into the power plug on the rear of 

the WineStation.

 

b.

Plug the power cord into the grounded  120 Vac., 

60 Hz. electrical outlet. 

(See Appendix Product 

Specifications).

 

c.

Open the door on the front of the system. Swing the spout cover to the up 

position. 

d.

Slide the power switch all the way up to the 

ON 

position.  

e.

The WineStation will run through a series of self-tests, which could take up to 

approximately 5 minutes. Once this process is completed, the green lights below 

the LCD screens will be illuminated, indicating that the WineStation is ready for 

service.

f.

If the control panel is locked, perform the following steps: 

Slide the power switch down one notch to the 

SERVICE MODE

 

Push 

WineStation  Service 

next to any of the displays. Push 

Exit.

 

Slide the power switch up to the 

ON 

position. The positions will now be un-locked. 

Napa Technology Customer Support 800.603.6550

Page 12

Congratulations!!!

You have completed the Hardware Installation.

You are now ready to set up your wine bottles.

Unpacking

 

and

 

Installing

 

your

 

WineStation(s)

Содержание Pristine PLUS CX

Страница 1: ...Napa Technology Customer Support 800 603 6550 WineStation Pristine PLUS CX Manual...

Страница 2: ...Pour hygienic dispensing technology with its unique seal and purge delivery will provide a winery fresh taste every time for a period of 60 days This feature allows you to uncork and enjoy multiple v...

Страница 3: ...Volumes 19 5 4 Prepping Bottles for Use 19 5 5 Setting the T emperature 20 5 6 Adjust Bottle Light 21 5 7 Pour Detection 22 5 8 Diagnostic Information 22 6 Cleaning and Care 23 Appendix 8 Product Spec...

Страница 4: ...at can happen if the instructions are not followed All safety messages will be preceded by the safety alert symbol and the hazard signal word DANGER WARNING or CAUTION These words mean Y ou will be ki...

Страница 5: ...s overloading facility wiring circuits which could cause a fire hazard from overheated wires It is recommended that a separate circuit serving only the WineStation be provided Use receptacles which ca...

Страница 6: ...nce DO NOT allow children to climb stand or hang on the WineStation doors They could damage the WineStation and seriously injure themselves Keep fingers out of pinch point areas clearances between the...

Страница 7: ...ng and preparation should be limited to qualified service professionals and trained staff only DO NOT place fingers or hands into the bottle bay assembly to to diagnose potential problems with the Win...

Страница 8: ...Clean Pour T echnology keeps Wine fresh for up to 60 days Locking Door WineGas Preservation System for Increased Wine Shelf Life Painted Steel Cabinet Napa Technology Customer Support 800 603 6550 Pag...

Страница 9: ...hat might interfere with the installation or operation of the unit Compliance with any applicable laws regulations standards and other legal requirements that may apply to the installation and operati...

Страница 10: ...position g Ensure that the WineStation is properly leveled If necessary adjust the four leveling feet on the bottom of the unit by turning them in the appropriate direction Normally all four leveling...

Страница 11: ...to the Gas connector located on the Rear of the WineStation Note If the WineStation will be positioned or mounted such that the Gas Cylinder will not be accessible from the rear an extension Gas hose...

Страница 12: ...o approximately 5 minutes Once this process is completed the green lights below the LCD screens will be illuminated indicating that the WineStation is ready for service f If the control panel is locke...

Страница 13: ...nd Colors The inner gaskets come in different sizes to fit various bottleneck widths Each gasket size has its unique color 1 Wide Green 2 Standard Red 3 Narrow White Cap Spout Pick Up Tube Collar Main...

Страница 14: ...properly mounted and the rotor switch is in the correct position See the Cleaning and Care section for more details d Insert a clean pick up tube into the bottle It is normal for the upper end of the...

Страница 15: ...ing and holding the bottle from the inside 1 Press down on the head with one hand The head should rest firmly on the bottle Do not let the tube push the head out of the bottle instead the tube should...

Страница 16: ...he collar until it touches the main body 3 Remove the dispensing head from the bottle and detach it from the pickup tube 4 Check the gasket for damage If needed replace with an undamaged head 5 Check...

Страница 17: ...ext move the switch back to the up position g Close the spout cover h Close the front door i Y our WineStation is now unlocked 2 WineStation Bottle Service Set Up Screen Default Settings a T o begin u...

Страница 18: ...o showcase Wine T ype Wine Y ear and Wine Varietal d Now you can select Wine T ype Red or White e Select the varietal by utilizing the side buttons to scroll through the list then press Exit The Prist...

Страница 19: ...s will appear on the Volume Size selection screen Using the buttons on the right you can set the desired pour volume in ounce increments as shown right 4 Prepping Bottles For Use a First insert the wi...

Страница 20: ...repeat this process for the other 3 positions 5 Setting the T emperature since this system is equiped with a Dual Zone divider this will set the temp for the right zone the white wine side a T o set t...

Страница 21: ...warmer temp Note Y ou may use Celsius or Fahrenheit d Y ou may also turn off cooling by selecting cooling mode as shown in the screen right 6 Adjust Bottle Light a T o adjust the Bottle Light return t...

Страница 22: ...pty bottle condition ii Pouring will continue to be accurate if this option is selected 8 Diagnostic Information The Diag screen menu can be selected from the WineStation Service screen to provide det...

Страница 23: ...ny fluid buildup Drip trays may be washed in warm water and mild detergent as needed and dried thoroughly before returning to position NOTE T o assure that condensation does not gather it is recommend...

Страница 24: ...and sanitizers when washing Clean Pour Dispensing Heads d After washing the cap can be reattached to the head body A small amount of lubricant spray should be applied to the gasket under the cap to en...

Страница 25: ...lubricated with a small spray of food grade silicone g Re position the cap on the head as follows 1 Position the triangular pointer towards the arrow 2 Press the cap down and turn it clockwise Cleani...

Страница 26: ...uching the head to minimize any unnecessary pressure on the gaskets j T o keep the WineStation operating properly and allow the Clean Pour Dispensing Heads to fit securely when inserted the O rings fo...

Страница 27: ...red Bottom 1 2 54 cm Operating Ambient Room Temperature Min 50 F 10 C Max 80 F 26 7 C Internal Wine Cabinet Temperature Approx 25 F to 32 F 10 C to 0 C Rating IPXO indoor or covered use only Ventilati...

Страница 28: ...50 Page 28 Appendix Product Specifications Napa Technology WineGas Cylinder Inert Gas WineGas Specialty UHP Argon Cylinder Size 9 5in H x 2 5in W Required Regulator Napa Technology PN 50 12121 Regulat...

Страница 29: ...Appendix Product Specifications Napa Technology Customer Support 800 603 6550 Page 29 Dual Zone Divider if present Non cooled Side For Reds Cold Side For whites Set desired Temperature For whites...

Страница 30: ...Appendix Product Specifications Napa Technology Customer Support 800 603 6500 Page 30...

Страница 31: ...e St Laurent Amarone Duriff Muscardin Terret Blanc Arneis Eiswein Muscat Terret Gris Auslese Fiano Negrette Terret Noir Baco Noir Frascati Neuburger Tinta Cao Barbaresco Gamay Niagra Tinta Narroca Bar...

Страница 32: ...ended you always use the Head Selection T ool when choosing the proper head for your wine bottle s Over tightening of the Clean Pour head will cause breakage please reference page 20 for proper handli...

Страница 33: ...Head Gasket Removal Replacement Napa Technology Customer Support 800 603 6550 Page 33 Step 6 Place one washer on the stem Then place selected size gasket on stem Carefully thread the nut back on to th...

Страница 34: ...apatechnology com or visit www napatechnology com argon gas Product Features Available Size 34 L Comes in pack of 3 Each 34 L disposable tank of Argon gas provides perservation and dispensing for appr...

Страница 35: ...oximately 17 degrees Celsius The only remedy to this condition is to lower the inlet temperature This can be achieved by either moving the WineStation to a cooler environment or cooling the inlet air...

Страница 36: ...not correct the problem then carefully clean the Pogo Pins located in the rear of the WineStation This can be accomplished by using the soft rubber in the back of a pencil When carefully pushing on th...

Страница 37: ...er needs to be replaced as soon as possible 6 Red lights are on in all or many units and pouring is not possible from these units a This indicates that the gas pressure being delivered to the WineStat...

Страница 38: ...return of defective part or parts to be repaired to Napa Technology Napa Technology will send a Service Technician on site to replace the defective part if the Labor Warranty is still valid or if a Pa...

Страница 39: ...or return of repaired or replacement product s back to Purchaser Napa Technology will make all reasonable efforts to repair or replace any returned product s within 10 business days of receipt In the...