Error number
Description
21
Non-volatile storage full, restart of controller for cleanup necessary
22
Nominal current must be set (203B:01)
Error Class[8]
This byte is identical to object 1001
Error Code[16]
The meaning of the two bytes can be seen in the following table.
Error Code
Description
1000
h
General error
2300
h
Current at output of motor controller too high
3100
h
Overvoltage/undervoltage at motor controller input
4200
h
Temperature error in motor controller
6320
h
Nominal Current must be set.
7121
h
Motor blocked
7305
h
Incremental or hall sensor faulty
7600
h
Flash storage full or corrupted, restart controller for a cleanup.
8000
h
Field bus error
8130
h
Only CANopen: Life guard error or heartbeat error
8200
h
Only CANopen: Slave needed too much time for sending a pdo message
8210
h
Only CANopen: PDO not processed due to length error
8220
h
Only CANopen: PDO length exceeded
8611
h
Position monitoring error: following error
8612
h
Position monitoring error: Reference switch hit and entered forbidden area
1008h Manufacturer Device Name
Function
Contains the device name as a string.
Object description
Index
1008
h
Object Name
Manufacturer Device Name
Object Code
VARIABLE
Data type
VISIBLE_STRING
Saveable
No
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
•
:
•
PD4-C5918M4204-E-01: PD4-C5918M4204-E-01
•
PD4-C6018L4204-E-01: PD4-C6018L4204-E-01
•
PD4-CB59M024035-E-01: PD4-CB59M024035-E-01