![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520086.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
86
Description
Motor Type [16]
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Device profile number [16]
Motor Type[16]
Describes the supported motor type. The following values are possible:
•
Bit 23 to Bit 16: value "1": Servo drive
•
Bit 23 to Bit 16: value "2": Stepper motor
•
Bit 31 to Bit 16: vlaue "255": Multiple device module
Device profile number[16]
Describes the supported CANopen standard.
Values:
0192
h
resp. 0402
d
(specified value): The DS402 standard is supported.
1001h Error Register
Function
Error register: In the event of an error, the corresponding error bit is set. It is automatically deleted
when the error no longer exists.
Object description
Index
1001
h
Object Name
Error Register
Object Code
VARIABLE
Data type
UNSIGNED8
Saveable
No
Access
Read only
PDO Mapping
TX - PDO
Admissible Values
Specified Value
00
h
Firmware Version
FIR-v1426
Change History
Description
PROF
7
6
5
4
3
2
1
0
COM
MAN
RES
CUR
GEN
TEMP VOL
GEN
General error
CUR
Current