Ramp/Soak Specs:  

10 steps per profile 

Program time and temps  

Save up to 25 profiles  

Save names per profile  

Linear ramping to temp.  

Over shoot +/- 5 % 

160degC thermal shutdown protection 

Buzzer on/off switch 

 

Pre-set Oven Profiles list: 

LMCO ramp soak Mil Spec. 

353ND 150c 1min 

353nd 120c 5 min 

353nd 100 10min 

353nd 80c 30min 

F112 90c 15min 

F123 100c 5min 

3577 150c 30min 

3677 120c 60min 

AB9123 100C 5 Min 

AB9123 120C 2MIN 

AB9123 150C 1MIN 

1min 100c 

 

 

 

 

 

 

 

Содержание SMART OVEN

Страница 1: ...Nanometer Technologies SMART OVEN Start up splash page press anywhere to continue during power up ...

Страница 2: ...button to turn it off there is a switch on the back to disable the buzzer as well c To use for a timed cure set the step time to that value Example 10 min then press run the buzzer will go off after 10 min TEMPS PAGE The TEMPS page sets the graph size Graph time scales 1x 36 sec per unit 2x 18 sec per unit 3x 12 sec per unit 4x 9 sec per unit Temperature Temp Set value valuevalueval ueTempuratur e...

Страница 3: ...the profile Profiles Page The Smart Oven comes pre loaded with many popular epoxy types and curing temperatures such as 353ND at 120 deg C for 5 min see the list at the end of this document Temp Set Temp Graph min max Graph update Temp Deg C HOM E Up arrow Down arrow Copy profile Edit Profiles Load Profiles ...

Страница 4: ...eps it will RAMP to the new temperature in the step time Process Step Description Temp C Duration min 0 00 Preheat Ramp 80 5 0 01 Preheat Soak 80 10 0 02 Temp 1 Ramp 100 3 0 03 Temp 1 Soak 100 7 0 04 Temp 2 Ramp 125 3 0 05 Temp 2 Soak 125 7 0 06 Temp 3 Ramp 150 3 0 07 Temp 3 Soak 150 7 0 08 Cool down 20C 15 Example of a Ramp Soak profile Step Step Time Step Temp Profile name Save Profile ...

Страница 5: ...port use the SmartOvenProfileSync exe program select the correct COM port USB connector internal to oven 3 Top Temp PID these are factory set do not change without contacting the factory 4 Alarm sets the Alarm temp the alarm display is on the HOME page 5 Save saves the settings ...

Страница 6: ...n 0 25deg C Accuracy 2 5 deg C 150deg C 2 deg C 25 120 thermocouple accuracy Max Temperature 150 deg C Stability lid closed 0 75 deg C Heating 12 deg Min Cooling 1 5 deg min Settling time 3 minutes Capacity 24 connectors variable depends on heater block Weight 5 lbs Power 120vac or 240 vac 3 amps Width 13 5 343mm Height 5 127mm depth 9 3 236mm ...

Страница 7: ...ng to temp Over shoot 5 160degC thermal shutdown protection Buzzer on off switch Pre set Oven Profiles list LMCO ramp soak Mil Spec 353ND 150c 1min 353nd 120c 5 min 353nd 100 10min 353nd 80c 30min F112 90c 15min F123 100c 5min 3577 150c 30min 3677 120c 60min AB9123 100C 5 Min AB9123 120C 2MIN AB9123 150C 1MIN 1min 100c ...

Страница 8: ...horized technician 2 16 If oven is used in any manner not specified in this manual the protection provided by the equipment may be impaired CAUTION DO NOT USE THIS PRODUCT IN ENVIRONMENTS WHERE FLAMMABLE OR EXPLOSIVE GASSES MAY BE PRESENT WARNING ACCESS TO THE POWER SWITCH AND PLUG SHOULD BE MAINTAINED FOR EMERGENCY DISCONNECT WARNING CAUTION HOT SURFACES This oven generates high temperatures duri...