PLEASE READ THESE INSTRUCTIONS
FIRST BEFORE INSTALLATION
Big things DO come in little packages!!! The revolutionary new Nanolux Ballast
is about to change everything you expect from the driving source of any
indoor garden, YOUR LIGHTING!!! This ballast is the smallest, lightest, and
most stable ballast on the market today.
The Nanolux ballast OG series is the
Authentic Original Nano
design on the
market.
In addition to the popular dimming function, which allows you to operate your
ballast at 110%(Super-lux), 100%, 75% and 50% power, we have also incorpo-
rated our new Random Start and NCCS system.
Random Start, gives each ballast a 0-15 second window upon which it will
strike the bulb. This allows for a less initial power draw when using multiple
ballasts for larger installations.
The Nanolux OG series have different output leads in different markets.The
detailed pictures are as below.
PRODUCT PICTURES
1)
Input voltage range: 120/220/240VAC
Option: 100/110/277VAC
2)
Power Factor:
≥
0.99
3)
Crest Factor:
≤
1.7
4) Total Harmonic Distortion (THD):
≤
10%
5) Operating Temperature:
-30°C (-22°F) – 55°C (131°F)
6) Output Frequency:
≥
30KHz
7) Strikes both HPS and MH lamps
8) Strikes bulbs from up to 50ft
1) Install your new Nanolux ballast away from any potential heat or
moisture sources. Although these units are made to withstand
extreme gardening conditions, keeping the unit as cool and dry
as possible will extend its life and not promote early failure.
2) Connect the output lead and socket to the lamp lead. (Ensure
bulb is inserted properly)
3) Plug the power connection (cord is provided) into power supply
socket.
4) Select your Dimming Selection: 110%(Super-lux), 100%, 75%,
50%.
5) Ballast has been intergraded with our new Fan Safety-Check
System: Fan will stop working when failure or obstruction.
(Ignore if no fan)
6) Ballast will protect under and over voltage:
North America & Japan:
under (90Vac) and over voltage (290Vac)
Europe & Australia:
under (155Vac) and over voltage(290Vac)
7) Ballast will attempt to restart after 50 seconds, and programmed
to shutdown automatically after 20 strike attempts for safety.
8) Ballast will automatically restart when the internal temperature
is under 55°C (131°F).
9) Ballast with short or open circuit protection.
10) When using a NCCS RTU in the USB port of a Nanolux ballast,
the Dimming function control dial on the ballast will be taken
out of function.
Failure to observe the following warnings may result in serious injury.
Warranties will be void if the following are not heeded.
1) Use only HPS or MH bulbs. Do not use lamps referred to as‘retro’or
‘conversion’lamps. Make sure the bulb matches the wattage of the highest
output of the ballast.
2) Never unplug the power plug or detach lamp cord from socket without turning
off the power supply first.
3) Make sure the power supply and lamp cable are connected properly and
grounded.
4) Do not hang the ballast by the power or lamp cord.
5) Mount each unit at least 150mm (6inches) apart.
6) Do not attempt to open or modify the Nanolux Ballast, high power electrical
devices can cause severe injury or death.
7) Ensure the unit does not come into contact with water.
8) Keep out of reach of children.
CAUTION
OPERATING INSTRUCTIONS
SPECIFICATIONS
NORTH AMERICAN & JAPANESE MARKET
EUROPEAN & JAPANESE MARKET
AUSTRALIAN MARKET
-01-
-02-
11) RTU is removed from the ballast during operation OR the RTU loses
communication with the DTU for any reason, the ballast will automa-
tically turn off after 10 minutes. The ballast has to be unplugged from
the power source and turned back on to reset. The ballast will then run
in regular mode (no NCCS) or if a RTU is plugged in, it will operate in
NCCS mode. If the ballast continues to turn off for any reason during
operation with the RTU in NCCS mode, replace the RTU and confirm
it is communicating with the DTU. For further NCCS APP customer
support and tech support pages, visit www.nanoluxtech.com.