background image

PLEASE READ THESE INSTRUCTIONS
FIRST BEFORE INSTALLATION

Big things DO come in little packages!!!  The revolutionary new Nanolux Ballast 
is  about  to  change  everything  you  expect  from  the  driving  source  of  any 
indoor  garden,  YOUR  LIGHTING!!!  This  ballast  is  the  smallest,  lightest,  and 
most stable ballast on the market today.

The Nanolux ballast OG series is the 

Authentic Original Nano

 design on the 

market.

In addition to the popular dimming function, which allows you to operate your 
ballast at 110%(Super-lux), 100%, 75% and 50% power, we have also incorpo-
rated our new Random Start and NCCS system. 

Random Start, gives each ballast a 0-15 second window upon which it will 
strike the bulb.  This allows for a less initial power draw when using multiple 
ballasts for larger installations. 

The Nanolux OG series have different output leads in different markets.The 
detailed pictures are as below.

PRODUCT PICTURES

1)

 

Input voltage range: 120/220/240VAC

                         Option: 100/110/277VAC

2)

 

Power Factor:

 

0.99               

3)

 

Crest Factor:

 

1.7

4) Total Harmonic Distortion (THD): 

10%

5) Operating Temperature:

 -30°C (-22°F) – 55°C (131°F)

6) Output Frequency: 

30KHz

7) Strikes both HPS and MH lamps
8) Strikes bulbs from up to 50ft

  1) Install your new Nanolux ballast away from any potential heat or 
      moisture sources.  Although these units are made to withstand 
      extreme gardening conditions, keeping the unit as cool and dry 
      as  possible will extend  its  life and  not promote early failure.
  2) Connect the output lead and socket to the lamp lead. (Ensure 
      bulb is inserted properly)
  3) Plug the power connection (cord is provided) into power supply 
      socket.
  4) Select your Dimming Selection: 110%(Super-lux), 100%, 75%,
      50%.
  5) Ballast has been intergraded with our new Fan Safety-Check 
      System: Fan will stop working when failure or obstruction.
      (Ignore if no fan)
  6) Ballast will protect under and over voltage:
      

North America & Japan: 

under (90Vac) and over voltage (290Vac) 

       

Europe & Australia:

 under (155Vac) and over voltage(290Vac)

  7) Ballast will attempt to restart after 50 seconds, and programmed 
      to shutdown automatically after 20 strike attempts for safety.
  8) Ballast will automatically restart when the internal temperature 
      is under 55°C (131°F).
  9) Ballast with short or open circuit protection.
10) When using a NCCS RTU in the USB port of a Nanolux ballast, 
     the Dimming function control dial on the ballast will be taken 
     out of function. 

Failure  to  observe  the  following  warnings  may  result  in  serious  injury.  
Warranties will be void if the following are not heeded.

1) Use only HPS or MH bulbs. Do not use lamps referred to as‘retro’or 
  ‘conversion’lamps.  Make sure the bulb matches the wattage of the highest 
     output of the ballast.
2)  Never unplug the power plug or detach lamp cord from socket without turning 
     off the power supply first.
3)  Make sure the power supply and lamp cable are connected properly and 
     grounded.
4)  Do not hang the ballast by the power or lamp cord.
5)  Mount each unit at least 150mm (6inches) apart.
6)  Do not attempt to open or modify the Nanolux Ballast, high power electrical 
     devices can  cause severe injury or death.  
7)  Ensure the unit does not come into contact with water.     
8)  Keep out of reach of children.

CAUTION

OPERATING INSTRUCTIONS

SPECIFICATIONS

NORTH AMERICAN & JAPANESE MARKET

EUROPEAN & JAPANESE MARKET

AUSTRALIAN MARKET

-01-

-02-

11) RTU is removed from the ballast during operation OR the RTU loses 
      communication with the DTU for any reason, the ballast will automa-
      tically turn off after 10 minutes. The ballast has to be unplugged from 
      the power source and turned back on to reset. The ballast will then run 
      in regular mode (no NCCS) or if a RTU is plugged in, it will operate in 
      NCCS mode. If the ballast continues to turn off for any reason during 
      operation with the RTU in NCCS mode, replace the RTU and confirm 
      it is communicating with the DTU. For further NCCS APP customer 
      support and tech support pages, visit www.nanoluxtech.com.