9. Maintenance
Visual and functional checks of the Purifier should be carried out daily:
•
Check the Purifier for any external damage.
Assess and eliminate any defects found.
•
Remove any loose dust or dirt from the Purifier; clean all surfaces that appear to have
attracted unwanted contaminants.
• Check the operation and readings on the CO monitor. Operate in accordance with
suppliers instructions.
9.2. Daily Checks
9.1. Cleaning
Clean the equipment with a damp cloth and if required a mild detergent may be used,
however do not use abrasives or solvents as they may cause damage.
A sample of compressed breathing air produced and delivered by the
compressed breathing air system must be collected and analyzed
every 6 months (or as specified by the authority having jurisdiction)
by an accredited lab. When the testing shows unacceptable levels of
contaminants, the system must be taken out of service and reinspected.
9.3. Sampling
•
Additional testing at regular intervals is recommended.
•
Re-testing the system is recommended when any major overhaul or extensive repairs
have been carried out.
Any noticeable odor must be analyzed.