Nanni N2.14 Скачать руководство пользователя страница 9

9

Installation inspection

Fuel supply system

The fuel tank of the engine must be placed as possible 
at the same level or slightly higher than the engine.

The return pipe must be placed under the mini level 
of the fuel tank.

The max height between the fuel pump and the 
mini level of the tank is indicated on the right. The 
standard pump is capable of sucking the fuel to a 
height of 0.5m. An electric pump has to be installed 
beyond this value.

1.

 Tank

2.

 Prefi lter

3.

 Fuel feed pipe Ø8 mm

4.

 Electrical pump (option)

5.

 Engine fuel pump 

6.

 Return fuel pipe Ø8 mm

Electrical installation

An incorrect or faulty electrical installation can 
cause leakage currents that can affect the galvanic 
protection of the engine and damage the engine 
subsequently.

The installer must ensure to take all necessary 
precautions to protect the engine against corrosion.

 

Auxiliary 12V output on instruments panel

The A4, B4 and C4 panels are equipped with an 
auxiliary output of 12V / 3A.

The interfaces linking the panels to the engine are 
fi tted with a fuse. 

Pump

Max height (m)

Standard pump

0.5

Electrical pump

1.8

1

3

2

4

5

6

Содержание N2.14

Страница 1: ...Instruction manual Marine Diesel engine N3 21 13122011 D MU_N3 21_970313240_ENG ...

Страница 2: ...NJECTION SYSTEM N3 21 Injection Indirect E TVCS Injection order 1 2 3 Injection pump BOSCH MD Mini type Injection pressure bar 140 LUBRICATION N3 21 Oil type temperate climat API CF SAE 15W40 Oil pressure at idle speed bar 1 Oil pressure at max speed bar 2 4 5 Engine oil capacity litre 3 COOLANT N3 21 Coolant litres 50 water 50 antifreeze 4 ELECTRICAL N3 21 Battery capacity mini Ah 35 50 Alternato...

Страница 3: ... Oil gauge 12 Oil filter 13 Heat exchanger 14 Coolant filler port 15 Sea water pump 16 Exchanger drain plug 17 Coolant pump 18 Flexible suspensions 19 Gearbox 20 Hoisting rings 21 Anode Non binding photographs The coupled equipment and accessories can vary according to your level of equipment 9 4 14 1 17 15 12 3 16 13 8 21 20 6 5 11 19 2 7 18 10 18 20 18 Main parts of the engine ...

Страница 4: ...ng the engine oil I Warning Hot oil can burn Avoid any contact with the skin Observe the environment protection rules A Oil drain port The oil is removed using a drain pump preferably engine slightly warm Fully pump out all the oil Fill with new oil Check the oil level using the gauge Do not exceed the maximum level Air filter A Air filter B Clamps I Warning Be sure no impurities get into the engi...

Страница 5: ...ilter cartridge This filter treats the water and impurities contained in the fuel before it flows into the injection system Cut off fuel intake at the tank Place a container below the filter and then dispose of the used filter cartridge C Refit the new filter by attaching it securely to the engine Turn up the hoses on the filter by squeezing the clamps Loosen the bleed screw to bleed the air open ...

Страница 6: ...eplaced Check that it fits properly in the ribbed grooves Check with your hand to confirm that the belt has not slipped out of the groove on the bottom of the pulley Seawater pump I Warning Close the seawater intake valve as there is a risk of water penetrating into the engine A Seawater pump B Impeller C Gasket Close the seawater intake valve Close the seawater pump cover Using a channel lock pli...

Страница 7: ...ould be between the lower edge of the filler neck and the level pin if equipped respectively representing the minimum and maximum level in the expansion chamber Top up if necessary using a fluid comprising 50 water and 50 antifreeze Degassing procedure Make sure that the drain plugs block heat exchanger are closed Open the vent plugs C and D heat exchanger clamp by pass Open the filler plug A and ...

Страница 8: ...swan neck shape to avoid any water getting into the exhaust system through the hull outlet 5 Anti siphon valve This is obligatory on boats whose engine is below the waterline The anti siphon valve must be installed at the end of the seawater system before injection in the exhaust elbow and must be positioned above the waterline between 0 5 and 2 meters 6 Seawater filter This must always be positio...

Страница 9: ...nk 2 Prefilter 3 Fuel feed pipe Ø8 mm 4 Electrical pump option 5 Engine fuel pump 6 Return fuel pipe Ø8 mm Electrical installation An incorrect or faulty electrical installation can cause leakage currents that can affect the galvanic protection of the engine and damage the engine subsequently The installer must ensure to take all necessary precautions to protect the engine against corrosion Auxili...

Страница 10: ...rk plugs are pre heating the combustion chambers if your engine has these Water in the diesel filter warning light optional This light comes on when there is too much water in the diesel filter Ignition This light indicates that the ignition is on Operation of an engine equipped with an Eco4 A4 B4 or C4 panel To start the engine 1 Put the throttle in the neutral position 2 Put the key into the ON ...

Страница 11: ... 30 20 5 35 15 25 STOP ON STOP START RPM x 100 10 0 40 30 20 5 35 15 25 C 40 60 80 100 120 F 105 180 220 250 STOP ON STOP START RPM x 100 10 0 40 30 20 5 35 15 25 bar 0 1 2 3 4 5 0 20 40 60 80 psi C 40 60 80 100 120 F 105 180 220 250 STOP ON STOP START Instrument panel ...

Страница 12: ...3 0 5 56 22 30 60 Fax 33 0 5 56 22 30 79 E mail contact nannidiesel com 2009 Nanni Industries SAS The images text and information contained in this document are based on the product s features at the time of publication Nanni Diesel reserves the right to modify this document without prior notice ...