3.Connect the AE-Y310 unit with external heater as in the below diagram: 

L N

H

L

N

HEATER

 

 

 

 

 

Warning! 

Beware of electric Shock! Always shut down electric power before installation. 

4.Slide the unit back to the panel plate. Check that the unit is firmly fixed onto the panel plate. 

Installation is completed.

 

1.Heater Control 

Switch on the unit by putting the Power switch at On position. Power LED (red) tums on. Set the rotary 

volume at the temperature you deserve. When room temperature is lower than the set temperature, the 

thermostat switches on the heater connected and at the same time, heat LED (green) turns on. When 

room temperature becomes higher than the set temperature, the thermostat switches off the heater and 

heat LED (green) tums off. 

2. Unit Off 

Put the Power switch at Off position. Thermostat stops running and there is no output to the heater 

connected. 

Product Specification: 

Model

AE-Y310 

Working Voltage

220VAC,50Hz 

Current Rating

16Amp(Resistive)

Maximum Rating

3500W 

Control Range

20℃-60℃(floor)

Temperature Accuracy

2℃

Span

1℃

Switching Type

SPST

Temp.Sensor Type

NTC sensor 

Working Temp. Range

0℃~60℃ 

Storage Temperature

-20℃~60℃ 

 