background image

 

FLAMIN’ FINGER

  

Operator’s 

Manual 

 

4.0 INSTALLATION 

Note:  Shipping damage may void the warranty.  In case of shipping damage, contact your 
distributor and the transportation carrier immediately. 

 

1. 

Unpack the game.  

2. 

With the game in its installation position, lower the leveler pads as required  

to eliminate any tilting of the game.  

 

3. 

Plug in the main AC power cord, and turn the game ON.   

  

4.1 

LINKING 

Games are shipped with 2 link cables. One is plugged into the output jack on the main pcb, 
and runs to one side of a female-to-female (f-f) connector mounted on top of the coin box, 
accessible through the coin door.  A second cable is plugged into the other side of the 
female-to-female connector and runs to the input jack on the main pcb. The link cables 
must be installed for proper game function.  

Linking can be done using one of two methods.   

SEE APPENDIX C FOR LINKING DIAGRAMS 

1. 

SEQUENTIAL.

  Recommended for 2 or 3 games, where the link cable can reach 

from the last game to the first game in the line of linked games. 

To link 2 or 3 games, unplug the link cable from the output side of the f-f connector of 
game 1. Route it through the small round hole in the back of the cabinet, into the hole in 
the back of the cabinet of game 2.  Unplug the link cable plugged into the output side of 
the f-f connector in game 2 and plug in its place the link cable just routed from game 1.  
Route the cable just unplugged from game 2 out of the cabinet and into the game 1 
cabinet, and plug it into the output side of the f-f plug in game 1.  

THE LAST LINKED GAME IN THE CHAIN OF GAMES MUST CONNECT BACK TO THE  

FIRST GAME IN THE CHAIN. 

2. 

STAGGERED.

 Recommended for 4 or more games. 

This method utilizes staggered routing, or every other game is linked. After the initial 
input-to-output linking of games 1 and 2, the odd number games are linked together, 
and the even number games are linked together. 

SEE APPENDIX C FOR LINKING DIAGRAMS 

 
 
 
 
 
 

Содержание FLAMING FINGER

Страница 1: ...OPERATOR S MANUAL...

Страница 2: ...f not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful i...

Страница 3: ...ONS 1 2 0 INTRODUCTION 2 3 0 PRECAUTIONS 2 3 1 Installation 2 3 2 Handling 2 4 0 INSTALLATION 3 4 1 Linking 3 5 0 SCREEN DESCRIPTIONS 4 6 0 GAME PLAY 8 7 0 TROUBLESHOOTING 9 APPENDIX A PARTS LIST 10 A...

Страница 4: ......

Страница 5: ...Dimensions 68 H x 22 25 W x 32 D Shipping Weight 227 lbs Controls Touch screen Convenience Kit Operator s Manual 1 in coin box Note Specifications subject to change without prior notice Modifications...

Страница 6: ...of an emergency i e near fire equipment or emergency exists 3 2 Handling 1 Before operating the game make sure that the main AC power hookup includes a safety ground This will ensure safe operation as...

Страница 7: ...LINKING DIAGRAMS 1 SEQUENTIAL Recommended for 2 or 3 games where the link cable can reach from the last game to the first game in the line of linked games To link 2 or 3 games unplug the link cable f...

Страница 8: ...X TIMES 1 The number set will make the coin in slot 2 worth that multiple of what is set in coin slot 1 For example if you want the coin in slot 2 to be worth the same as a coin in slot 1 set the numb...

Страница 9: ...game will automatically maintain this average by adjusting its internal difficulty setting based upon the players at your location NOTE 2 If you have multiple games linked this setting will apply to a...

Страница 10: ...ng items can be selected 20 REDS ON YELS ON MEM TEST BURN IN Press inside one of the red boxes to select between turning all red or yellow led s on performing a memory test or running burn in Press th...

Страница 11: ...an emitter or receiver has failed to communicate 32 PRESS MENU TO SYNC ALL GAMES This screen is displayed when data is not matching across multiple games Press the service menu button located inside c...

Страница 12: ...ficulty set by the skill level of the players that have won the jackpot The game time is not adjustable by the operator However game difficulty can be adjusted indirectly by the operator by changing t...

Страница 13: ...ould be 5 15VDC ORG to BLK should be 12VDC 0 1 8VDC If 12VDC is bad check for output shorts by removing load connectors one at a time ref overall wiring diagram in Appendix If loads are OK or if 5VDC...

Страница 14: ...10972 00 SOCKET LAMP COMPACT FLUORESCENT FI57 10922 00 STROBE LENS RED FI95 10973 00 PLEX PLAYFIELD FI40 10914 00 DECAL GAME INSTRUCTIONS FI05 10918 00 CPU MAIN LOGIC VG88 08776 00 POWER SUPPLY 200W...

Страница 15: ...FLAMIN FINGER Operator s Manual 11...

Страница 16: ...FLAMIN FINGER Operator s Manual 12 APPENDIX B WIRING DIAGRAM...

Страница 17: ...FLAMIN FINGER Operator s Manual 13 APPENDIX C LINK DIAGRAMS...

Страница 18: ......

Страница 19: ...all Seller be liable for loss of profits loss of use incidental or consequential damages Except for any express warranty set forth in a written contract between Seller and Buyer which contract superse...

Страница 20: ...3900 FAX 408 436 9554 Technical Assistance USA 408 383 3973 Fax 408 436 9554 Reorder Number FI45 10919 00 REV A NOVEMBER 2003 The specifications of this machine and the instructions in this Operation...

Отзывы: