Quicksilver QS-100 User Guide – Revision C
Document Number: 451-19004-001C
29 of 74
3.
At the end of the product firmware update, the Quicksilver restarts and the current
user login session ends.
The product firmware update is supported at all times. If the Quicksilver fails to start normally
due to any possible errors such as having a corrupted product firmware image, the device
enters the recovery mode. In recovery mode, the device firmware can be updated. For
information on the recovery mode, refer to section
4.5.2
I
RIDIUM
Figure 21: Iridium Firmware Update Page
NOTE: Iridium update files will not be accepted unless they end with an ".esbin"
extension. This is to help avoid updating the Iridium modem with invalid
firmware.
NOTE:
Failed and partial statuses may have an error message(s). After an
update, the update log should be checked to see if the update was successful.
If an update fails, apply the update again. If update failed with partial status,
reapply the update. If reapplying the update is successful, this should repair
any corruption to the file systems. If the device enters recovery mode,
product updates can still be applied over TCP using a command line program.
Please contact NAL for help with this.