18
6
㧚
CONNECTION
POWER SOURCE CONNECTION
•
The following lists the recommended earthing conductor and its crimped terminal.
1
Screw an earthing conductor to the FG terminal on the back of the
Equipment.
2
Connect the power cable to the 230 V AC (50/60 Hz) power source.
•
Use a 3-pole insertion power plug.
•
If the plug socket is of 3 poles (earthed), connection of the earthing conductor in Step 1
is not required.
Confirm that the POWER lamp (green) has been turned on.
3
Part Name
Crimped
terminal
Specification
R2-4 or its equivalent.
Solid wire
㧦
1.14
㨪
1.84mm
Twisted pair wire
㧦
1.04
㨪
2.63mm
2
Applicable Thread Diameter
M4
Part Name
Earthing
conductor
Specification
600V-IV wire or its equivalent.
Solid wire: Conductor diameter 1.6 mm.
Twisted pair wire: Sectional area 2mm
2
•
If turned off, contact our dealer.
Power Cable
ޓ
(3-pole Insertion Plug)
Front of NYC-16VDSL-B
Back of NYC-16VDSL-B
POWER Lamp
Earth
FG Terminal
AC230V
٨
Never use the power source of other than 230 V AC (50/60 Hz). Neglect of this may result in a fire,
electric shock or trouble.
٨
It is prohibited to connect the earthing conductor to a gas pipe. Neglect of this leads to an explosion.
WARNING
٨
Separate the power cable from the wiring of the noise emitting apparatuses (motored devices, arc
discharge devices, devices using a coil). Neglect of this may cause the Equipment to have a trouble or
malfunction.
٨
Be sure to connect an earthing conductor to the Equipment. Neglect of this may cause it to go out of
order.
CAUTION
٨
When turning on the power again, disconnect the power plug from the plug socket, wait for
10 seconds or more, and then, reconnect it to the plug socket.
Notes