EN
1
8
OIl bath type
1. Remove the nut and air cleaner housing, and take out the filter element.
2. Clean with home detergents (or high flash-point cleansing solvents) and warm water, and dry up.
3. Soak in clean engine oil until saturated. Squeeze excess oil, or the engine will discharge smoke in
starting stage.
4. Empty the air cleaner housing of oil. Clear away the dust inside with non-flammable or high flash-
point cleansing solvents, and dry it up.
5. Fill the air cleaner housing with the specified engine oil up to the standard oil level mark.
6. Reinstail the air cleaner.
WASHING OF DEPOSIT CUP
Set the fuel cock at "OFF", disconnect the deposit cup and O-ring. Wash in non-flammable or high
flash-point cleansing solvents, and then try thern up, at last, reinstall it . Set the fuel cock to "ON" and
check for leaks.
WARNING
- Gasoline is extremely flammable and explosive in certain conditions. Keep cigarette, sparks and open flames away.
- After reinstalling the deposit cup, make sure the area around the engine is dry enough.
SPARK PLUG
Spark plug type: BPR6ES(NGK) or NHSp LD F6RTC
Proper spark plug clearance ensure the engine's normal running under no deposit around the spark plug.
Warning: Be careful not to touch the muffler during or just after running the engine.
O-ring
Deposit cup
Foam
Air cleaner housing
Foam
Standard oil
level mark