25
26
(3) Input/Output Signal
(2) Input/Output Diagram
1
+24V or 0V
Load
6,7,8,20,21
(COM_2)
18
0V or +24V
The side of unit
The side of unit
1
(COM_1)
0V or +24V
+24V or 0V
The side of unit
18
(COM_2)
+24V or 0V
0V or +24V
19
(PLUSE)
Load
Fig. 36
Output Signal
2
Refer to Fig. 36 for about the Output Signal of Rotating Pulse. The output current can be
connected to both the sink and the source.
Voltage and Current Specifications
• Applied Voltage (V max)
30VDC • Working Current (Ip)
50mA
Input Signal
There are 8 kinds of input signals : rotation command, rotation direction, error release,
speed up-down signal, speed command pulse signal, motor selection signal 0, motor
selection signal 1,500 min
-1
speed command. These signals are +24VDC signals from an
external signal source.
Output Signal
1
There are 5 kinds of output signals : rotating, rotating direction, error, warning and rotating
speed achieved. There signals are MOSS Relay Contact Connections. The output current
can be connected to both the sink and the source.
Voltage and Current Specifications
• Applied Voltage (V max)
30VDC • Working Current (Ip)
100mA
Use an external power source for output circuits.
It is recommended to use the same 24VDC power source used for input signals. Please
refer to Fig. 35 for connections.
Fig. 34
Fig. 33
2
Fig. 35
3
COM_1
START
(+24V or 0V)
(0V or +24V)
DIR_IN
RESET
500min
SEL0
SEL1
UD_IN
CNT_IN
Potentionmeter
COM_2
RUN
DIR_OUT
ERR
WARNING
COIN
PULSE
MT-CNA
MT-CNB
AUTO+
AUTO-
PWON+
PWON-
EMG-IN+
EMG-IN-
VR
GND
GND
MOTOR_1
+10VDC
LOAD
SPEED_V
SAFE-1A
SAFE-1B
SAFE-2A
SAFE-2B
SAFETY RELAY CONTACT
1
14
2
4
16
17
5
15
3
11
23
10
1
Connector A
(D-Sub25)
Connector B
(D-Sub15)
NE260 UNIT
9
6
7
8
20
21
19
18
12
24
25
13
2
13
10
5
14
3
11
4
6
12
*
NE260-OP1 use Pin No. 1, 3, 4, 9, 11, 12
NE260-OP1 UNIT
Please use a separate power source that is capable of supplying 24VDC±10 %, 100mA.
Refer to Figures below for connections.
*
When using NE261, input signal : Motor Selection Signal 0, Motor Selection Signal 1.
*
By setting parameter, Motor Speed change is possible by pulse signal.
If input “Speed up-down signal” “Speed Command pulse signal”.