17
TROUBLESHOOTING
Symptom:
Tool operates properly but fasteners do not drive fully.
Solution:
Check fuel cell and replace as required.
Symptom:
Tool operates properly but fasteners are sometimes over driven and sometimes under driven.
Solution:
Use only fasteners that meet Nailfire specifications. Check applications section for fastener types
and size recommended. Position feeder shoe behind fastener strip. Clear jam.
Symptom:
Tool operates erratically or appears to be losing power.
Solution:
Check fuel cell. Check spark plug wire. Remove filter element and replace.
Check recommended cleaning schedule and service if required.
Be sure safety element is completely engaged.
Symptom:
Tool operates and drives fasteners but driver blade does not return to the up position.
Solution:
Take care that the safety element is completely engaged when driving fasteners.
Return to the authorised Nailfire dealer for service.
Symptom:
Combustion chamber does not drop after tool cycle.
Solution:
Clear or replace work contacting element.
If tool will not operate after following the above service directives, return the tool to the authorised
Nailfire dealer for service.