background image

CONTROLS AND CONNECTORS

5

FRONT PANEL

Front Panel

(1) POWER SWITCH

Use this switch to power unit ON or OFF. The integrated LED will

light when the unit is ON. Before turning on this unit, verify

connection to the proper voltage AC source, check all connections

and turn down the level controls of equipment connected to the

outputs.

(Note: The TMP-1 will not output audio for approximately 16

seconds after power up due to the time it takes for the tubes to

warm up. Do not turn up the audio until after this warm up period

to avoid possibly damaging speakers or your hearing due to

improper level settings.)

(2) INPUT CONTROL

The INPUT CONTROL sets the amount of input gain of the

TMP-1, turn the control clockwise to increase gain and counter-

clockwise to decrease gain. You may control two ranges of gain

with this control, +26 to +60dB and +6 to +40dB. Selection of the

gain range is made with the +20dB GAIN SWITCH (3)

(3) +20dB GAIN/NORM SWITCH

Use the +20dB GAIN/NORM switch to set the gain range of the

INPUT CONTROL (2). When the switch is out, the TMP-1

operates in Normal mode, depressing the switch adds 20dBs of

gain. For microphone applications, where more level is needed,

push the switch in.

(4) PHANTOM POWER SWITCH

Use the PHANTOM POWER to supply power to all microphones

req48V phantom power. The TMP-1 phantom power is

engaged and disengaged with this switch Phantom power is

applied to pins 2 and 3 of the XLR INPUT (13) jacks when this

switch is pushed in. To disengage phantom power, position the

switch in the out position.

(1)

(9)

(8)

(5) OUTPUT LEVEL VU METER

The output level of the TMP-1 can be monitored using the analog

OUTPUT LEVEL VU METER.  The meter’s 0dB marking repre-

sents +12dB at the XLR output and +6dBu at the 1/4" output.  The

output meter will also reflect any attenuation due to the output

limiter when it is engaged.

(6) CLIP/LIMIT LED

The CLIP/LIMIT LED lights green when the unit is powered.  The

LED also functions as a clipping and limiting indicator.  The LED

lights red when the audio signal reaches 6dB below hard clipping.

If the OUTPUT LIMITER SWITCH (8) is depressed, the LED will

light red when the limiter engages at which point the gain will be

reduced automatically to avoid clipping.

(7) PHASE REVERSE / NORM SWITCH

When the switch is in the Out position of the output signal is

normal. Depressing the switch reverses the phases of the output

signal. In multi-microphone applications, mic placement can affect

the phase of the signals. If your sound is “thin” or “out of position”,

reverse the phase to correct the problem.

(8) OUTPUT LIMITER SWITCH

When this switch is depressed the output level is limited to 0dB for

the 1/4 output and +6dB for the XLR output.  This is specially

designed to prevent clipping of the audio waveform.  This also

reduces the possibility of overload to any units connected to the

outputs of the TMP-1.

(9) OUTPUT CONTROL

The OUTPUT CONTROL sets the output level of the TMP-1.

When the control is fully counterclockwise the output level of the

TMP-1 is zero. Turning the control clockwise increases the level of

the output to a maximum of +10dB of gain. This gain is in addition

to the existing input gain.

(7)

(6)

(5)

(4)

(3)

(2)

Содержание TMP-1 MICPREAMP

Страница 1: ...TMP 1 MIC PREAMP TUBE MICROPHONE PREAMPLIFIER O W N E R S M A N U A L...

Страница 2: ...ADY AUDIO TMP 1 has superior performance and greater flexibility than any other tube mic preamps in its price range Please read this manual carefully to get the most out of your new unit Thanks for se...

Страница 3: ...n the ears you should consult an audiologist 5 The product should be positioned so that proper ventilation is maintained 6 The product should be located away from heat sources such as radiators heat v...

Страница 4: ...ough space around the unit for cooling at least 12 or 30cm Do not place the TMP 1 on high temperature devices such as power amplifiers etc or the unit may overheat in operation Also do not place the u...

Страница 5: ...antom power position the switch in the out position 1 9 8 5 OUTPUT LEVEL VU METER The output level of the TMP 1 can be monitored using the analog OUTPUT LEVEL VU METER The meter s 0dB marking repre se...

Страница 6: ...r cord check to see that the unit is set for the proper voltage for your area 115V 60Hz or 230V 50Hz Note Use at the improper voltage can damage your unit and void the warranty 13 12 OUTPUTS Unbalance...

Страница 7: ...OR FROM THE BREACH OF ANY REPRESENTATION OR WARRANTY LICENSE The Company grants the customer a non exclusive non transferable license to use the software if any accompanying this product for internal...

Страница 8: ...l at service nady com International For service please contact the NADY AUDIO distributor in your country through the dealer from whom you purchased this product DO NOT ATTEMPT TO SERVICE THIS UNIT YO...

Отзывы: