10. FUSE COMPARTMENT

Replace with only the same type fuse. If the fuse blows continuously, have the unit serviced by 

qualified personnel. The PM-200A powered mixer uses 20mm glass tube Fast Blow fuses: 6A 

250V for 115VAC, 3A 250V for 230VAC.

11. AC VOLTAGE SELECTOR SWITCH

Before plugging in the power cord, check to see that the unit is set for the proper voltage for 

your area: ~115V (60Hz) or ~230V (50Hz).

12. HEAT SINK

The heat sink can get very hot during high power operation. Make sure to leave properly 

ventilated and avoid touching.

13. MOUNTING SOCKET

On the bottom panel of the PM-200A 

is a 5/8” dia. socket for mounting the 

PM-200A on a mic stand. Depending 

on your mic stand, you may require 

the optional MSA-100/200A Mic Stand 

Adapter for most secure mounting. For 

ordering, see PM-100/200A Optional 

Accessories Ordering Form included.

13

PM-200A bottom and 

standard mounting socket

MSA-100/200A Mic 

Stand Adapter

Mic Input

 

balanced XLR 

  Input Impedance 

2KΩ 

  Maximum Input 

-10.2dBm (235mV) 

  Sensitivity (for max output 

  w/Volume max) 

-40dBm (7.5mV)

Line Input

 

balanced/unbalanced TRS 1⁄4” 

  Input Impedance 

20KΩ

   

(10KΩ unbalanced)

  Maximum Input 

+22dBm (10V) 

  Sensitivity (for max output 

  w/Volume max) 

-10dBm (230mV)

Line Output

 

balanced XLR 

  Output Impedance 

1.4KΩ 

  Maximum Output 

  (w/10K load) 

15.5dBm (4.3V)

EQ and Volume

 

rotary knobs 

  High 

+/-12dB @ 10K Hz 

  Mid 

+/-12dB @ 2.5K Hz 

  Bass 

+/-12dB @ 120 Hz

Headphone Output

 

1⁄4” TRS Stereo 

  Power 

2 x 80mW @ 32Ω

Power Amp Output

 

2 internal speakers, 

   

2 external 1⁄4” outputs

  Power 

2 x 50W RMS @ 8Ω 

   

(Total 100W RMS)

   

2 x 75W RMS @ 4Ω 

   

(Total 150W RMS)

  Frequency Response 

20Hz – 50KHz 

  THD 

0.055% 

  S/N 

-81dB 

  Noise Floor 

.200uV 

  Amplifier protection 

clipping LEDs, 

   

        thermal runaway, short circuit, 

   

anti-thump on/off protection

Internal Speakers

 

5” full-range 

  Impedance 

8 Ω 

  Voice Coil diameter 

1”

Power Requirements

 

Selectable, 

   

115VAC/60Hz or 230VAC/50Hz

Fuse Requirements

  5x20mm glass tube F.B. 

   

6A 250V @ 115VAC

   

3A 250V @ 230VAC

Weight

 

9.6 lbs. (4.4 Kg)

Dimensions (HWD)

 

11.1” x 7” x 6.1” 

   

(28 x 18 x 15.5 cm)

Specifications subject to change at any time 

without prior notice for purposes of product 

improvement

Содержание PM-200A

Страница 1: ...PM 200A STAGE MONITOR Powered Personal Stage Monitor O W N E R S M A N U A L...

Страница 2: ...al carefully to get the most out of your new unit Thanks for selecting Nady Audio as your choice in personal stage monitors Table of Contents FEATURES FEATURES 2 WARNING 3 PANEL CONTROLS CONNECTIONS 4...

Страница 3: ...d should 1 be undamaged 2 never share an outlet or extension cord with other devices so that the outlet s or extension cord s power rating is exceeded and 3 never be left plugged into the outlet when...

Страница 4: ...ts more than occasionally you should turn down the volume to avoid audible distortion and possible damage to the speakers or amplifier The PM 200A uses a high power amplifier in a small enclosure for...

Страница 5: ...nel If an 8 speaker is connected to each output the power amp can deliver up to 75W RMS to each channel that means 37 5W per speaker If the internal speakers are turned off in this configuration each...

Страница 6: ...dapter Mic Input balanced XLR Input Impedance 2K Maximum Input 10 2dBm 235mV Sensitivity for max output w Volume max 40dBm 7 5mV Line Input balanced unbalanced TRS 1 4 Input Impedance 20K 10K unbalanc...

Страница 7: ...artment Any service not performed by Nady will automatically void this warranty 2 Items not covered physical damage resulting from improper handling of the unit in transit from the factory by the ship...

Страница 8: ...or money order or pay by credit card per instructions by the Nady Service Department Ship your unit prepaid to Nady Systems Service Department 6701 Shellmound Street Emeryville CA 94608 Include a brie...

Отзывы: