TP5 TP6
TP7 TP8
VR302
VR
30
1
VR
40
1
D3
05
D4
05
VR402
ALIGNMENT PROCEDURE
A. OUTPUT OFFSET VOLTAGE
1.Push Power on, preheat unit for 5 minutes.
2.Connect the DC Millivoltmeter to L Channel speaker output terminals or TP5 and
TP7, adjust VR301 to get a reading of 0V
±
30mV.
3.Connect the DC Millivoltmeter to R Channel speaker output terminals or TP6 and
TP8, adjust VR401 to get a reading of 0V
±
30mV.
B. IDLING CURRENT
1.Connect the DC Millivoltmeter across D305, adjust VR302 for 160
--
180mV reading
on meter.
2.Connect the DC Millivoltmeter across D405, adjust VR402 for 160
--
180mV reading
on meter.
- 5 -