AUTO SENSE 

Auto sense feature enables the C 368 to wake up from standby mode 
when triggered by network connected App or active source input.

ON
• 

Unit wakes up from standby mode when triggered by network 
connected App or active source input.

• 

Except for analog input, the unit will power up to the Source that 
activated the unit to operating mode.

• 

When the unit is triggered by an active analog input, the unit will 
always power up to Line 1. 

OFF
• 

Unit remains at standby mode even if it is triggered by network 
connected App or active source input.

Refer also to table below about “OPERATING MODE TRIGGER POINTS”.

OPERATING MODE TRIGGER POINTS

SETTINGS

OPERATING MODE TRIGGER

Auto Standby: On

Network Standby: On

Auto Sense: On

Unit switches back to operating mode by

•  resuming activity at network connected app.

•  an active source input. 

•  pressing front panel Standby button or SR 9 remote 

control’s [ON] button.

Auto Standby: On

Network Standby: Off

Auto Sense: On

Unit switches back to operating mode by

•  an active source input. 

•  pressing front panel Standby button or SR 9 remote 

control’s [ON] button.

Auto Standby: On

Network Standby: On/Off

Auto Sense: Off

•  Unit remains at standby mode even if it is triggered 

by network connected App or active source input.

•  Unit can only be switched back to operating mode by 

pressing front panel Standby button or SR 9 remote 

control’s [ON] button.

IR CHANNEL

The C 368 has the capability to operate via Alternate IR channel. This is 
useful if you have two NAD products that can be operated by similar 
remote control commands. With alternate IR Channel, two different NAD 
products can be controlled independently in the same zone by setting 
each one to a different IR channel.

IR Channel Assignment

The C 368 and the SR 9 remote control must be set to the same channel. 

To change the IR Channel on the C 368

While at IR Channel menu, use the [

a/s

] to select through Channel 0 to 

Channel 3. Press [ENTER] to select preferred IR Channel setting. C 368 IR 
Channel is defaulted to Channel 0. 

To change the IR Channel on the SR 9 remote control
• 

Include a channel number before the library code. For SR 9, library code 
“10” is the default library table for “AMP” device. To select this “AMP” 
library table for Channel 0, retain the library code “10” (or “010”). 

• 

If you want to load the “AMP” library table on ”Channel 1” prefix the 
library code with “1” to indicate association with “Channel 1”. Load then 
the “AMP” library table using the code “110”. Repeat the same for MP 
(130) and TUNER (140).

SAMPLE SETUP OF TWO NAD PRODUCTS ON THE SAME ZONE 

NAD C 368 and NAD C 390DD are both defaulted to Channel 0. If [OFF] 
button is pressed on the SR 9 remote control (or AVR 4 remote control for 
the C 390DD), both products will go to standby mode. Press [ON] and both 
products will power up from standby mode.

To prevent both products from simultaneously going in and out of standby 
mode along with other common commands, set each one to a different 
IR channel. In this setup, we will keep C 390DD and AVR 4 remote control 
defaulted to “Channel 0”. As for C 368, we will assign it to “Channel 1”; the 
same applies to SR 9.

Set C 368 and SR 9 to “Channel 1” via the following procedure.

C 368

While at “IR Channel” menu, use the [

a/s

] to go to “Channel 1” setting. Press 

[ENTER] to select “Channel 1”. 

SR 9
• 

Press and hold [AMP] in the DEVICE SELECTOR section of the SR 9. 

• 

While holding down the device button [AMP], press “1”, “1” and “0” using 
SR 9’s numeric buttons. 

• 

Press [ENTER] while still holding down the device button [AMP]. The 
AMP device selector will flash once to indicate that the library input is 
successful. 

With both C 368 and SR 9 set to “Channel 1”, the C 368 can now be 
remotely controlled independent of the C 390DD.

NOTE

 

Performing a Factory Reset for C368 or SR 9 will restore their respective 
IR channel setting to “Channel 0”.

OPERATION

USING THE C 368

IR Channel

Settings

Source Setup

Channel 0

Settings

Auto Sense

Settings

Source Setup

Off

Settings

16

ENGLISH

FR

ANÇ

AIS

ESP
AÑOL

IT

ALIANO

DEUT

SCH

NEDERL

ANDS

SVENSK

A

РУ

ССКИЙ

Содержание C 368

Страница 1: ...ENGLISH FRAN AIS ESPA OL ITALIANO DEUTSCH NEDERLANDS SVENSKA Owner s Manual C368 Hybrid Digital DAC Amplifier...

Страница 2: ...nal Electrical Code ANSI NFPA 70 provides information with regard to proper grounding of the mast and supporting structure grounding of the lead in wire to an antenna discharge unit size of grounding...

Страница 3: ...ny interference received including interference that may cause undesired operation Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or l...

Страница 4: ...ss and hold both front panel s a SOURCE s buttons until the display shows FACTORY RESET Release both a SOURCE s buttons afterwards IMPORTANT SAFETY INSTRUCTIONS 2 INTRODUCTION GETTING STARTED 4 WHAT S...

Страница 5: ...mm personal stereo jack plugs 5 DISPLAY Show visual and menu information according to the selected settings The following Main menu options are shown in the display Source Setup Settings and BluOS Set...

Страница 6: ...specialists with respect to their compatibility to the C 368 s IR features IR IN This input is connected to the output of an IR infrared repeater Xantech or similar or the IR output of another compati...

Страница 7: ...to connect and no loose strands of speaker wire 8 POWER Supplies the AC mains power to the C 368 When the POWER switch is set to ON position the C 368 goes to standby mode as shown by the amber statu...

Страница 8: ...also support both features are interconnected with C 368 via HDMI connection If an ARC connection is established the front panel display will show HDMI ARC IMPORTANT Ensure that ARC connected devices...

Страница 9: ...selector 8 inAMPmodewill nowcorrespondtoBluetoothsourcewhileinputselector 9 willbeunassigned Refertoexamplebelow If you installed the optional MDC BluOS or MDC HDM 2 module the unassigned input select...

Страница 10: ...der RPT Repeat track file or whole disc PROG Enter or exit program mode CLEAR Delete programmed track file CD Select CD as the active source USB Select USB as the active source OPT Select optical inpu...

Страница 11: ...Press ENTER while still holding down the device button CD The CD device selector will flash once to indicate that the library input is successful Both the device selector button CD and ENTER can now...

Страница 12: ...the NAD Remote App from the respective App stores of Apple iOS devices iPad iPhone and iPod and Android devices USING THE NAD REMOTE APP After downloading the NAD Remote App from the App store ensure...

Страница 13: ...e on the current character The name can be as long as fourteen characters 3 Repeat steps 1 and 2 for each character in sequence 4 Complete the renaming process by pressing the ENTER button again to sa...

Страница 14: ...t the balance levels 0 dB level setting provides equal level to the left and right channels FILTERS Filters provide easy bi amplification or subwoofer integration by adding the required filters to red...

Страница 15: ...ghtness NETWORK STANDBY Network Standby mode maintains network connection at standby mode with reduced system performance level On Network connection is maintained at standby mode Off Network connecti...

Страница 16: ...h Channel 0 to Channel 3 Press ENTER to select preferred IR Channel setting C 368 IR Channel is defaulted to Channel 0 To change the IR Channel on the SR 9 remote control Include a channel number befo...

Страница 17: ...nother device Sink on the same Bluetooth network environment C368 AS A BLUETOOTH SINK Set BT Work Mode to Sink Initiate pairing of your Bluetooth device with C 368 by following below procedure 1 Ensur...

Страница 18: ...T antenna terminal at the rear panel 1 Select Bluetooth as a Source Display could show any of the following Connectable Discoverable C 368 is open to connect or pair with other Source devices within t...

Страница 19: ...configured only at BluOS source mode With other sources the BluOS Setup menu options can be viewed only but not configurable INFO Display MAC address IP address BluOS version and other related inform...

Страница 20: ...ontinuous output power into 8 ohms Bridge mode 300W ref 20 Hz 20 kHz atTHD 0 03 THD 20 Hz 20 kHz 0 03 250 mW to 80W 8 ohms and 4 ohms Signal to Noise Ratio 98 dB A weighted 500 mV input ref 1W out in...

Страница 21: ...21 ENGLISH FRAN AIS ESPA OL ITALIANO DEUTSCH NEDERLANDS SVENSKA...

Страница 22: ...nal a division of Lenbrook Industries Limited No part of this publication may be reproduced stored or transmitted in any form without the written permission of NAD Electronics International While ever...