THERMOCONTAC
FUSE 4 AMP
4AMP
R/BL
IGNITION SWITCH
BATTERY
FAN
R/BL RED / BLACK + FROM IGNITION SWITCH
WH
WHITE
+ FROM FAN
-
+
WH
- In order to check the correct opera-
tion of the expansion reservoir cap
overpressure valve, use a manome-
ter with an appropriate adapter for
the thread of the cap.
- In vehicles equipped with the elec-
tric fan, fan operation should also
be checked after filling and bleeding
the cooling circuit, as per the follo-
wing specifications:
- In the event that the electric fan
does not come into operation, check
the following:
1. Main fuse
2. Battery voltage charge
3. The electrical circuit operating the
fan.
- If no anomalies or faults are disco-
vered in these areas, proceed to
replace the electric fan thermo-
switch, which is located on the
upper radiator cover.
6-4
CONNECTION TEMPERATURE ºC
OFF - ON
97
±
3
ON - OFF
85
±
3