21
Showing location of Viewing panel for
charging-light sequence.
Yellow:- Charging Normally, 23 hours MAX
Yellow Flashing:- Charging Finished, (Trickle Charging)
Green:- Fully Charged
Red:- Remove Mains Supply
Failure of charger profile – corrective action replace faulty battery
Charging stopped. time out timer expired (27hrs) -
corrective action replace faulty batteries
Internal charger failure – corrective action replace charger
To ensure your machine remains at its maximum efficiency and prolong your battery life, please follow
the simple steps below:
Under normal daily usage:
Recharge batteries after each use regardless of machine operation time
(see page 19).
Recharge the machine fully after its last use. Do not leave the machine in a discharged state.
Battery Care
Under abnormal use; i.e. leaving the machine without charging
for a period of time, we advise that you follow these steps:
If the machine will be standing unused for a period of 30 days
or more, then batteries must be fully charged and battery fuses
removed using the Maxi fuse-puller provided, prior to this period.
Batteries should be recharged every three months.
Charge fully the day before you start using the machine again.