Changing the Floor-tool blades
!
!
AlWAyS ENSURE tHAt tHE bAttERy IS dISCONNECtEd PRIOR tO ANy
MAINtENANCE
To change the floor-tool, firstly swing the floor-tool clear of the
machine (Fig 41).
Undo the two floor-tool retaining knobs (Fig 42).
Unscrew the four knobs securing the blade holder (Fig 43).
Remove the blade holder (Fig 44).
Replace the Squeegee blades using (606261) replacement blade set (Fig 45), fitting the blades on to the moulded
location lugs.
Refit the blade holder, retain using the two outer knobs
(Fig 46)
Refitting the Floor Tool Blades
Ensure the slotted blade goes to the front of the
floor-tool (Fig 47).
Refit the floor-tool using the two central knobs to
the floor-tool.
Refer to Page 9 for fitting instructions.
1. Floor-tool main body
2. blade carrier
3. Rear blade
4. Front blade (slotted)
5. Retaining Knobs x 4
1
2
3
5
4
Fig 41
Fig 42
Fig 43
Fig 44
Fig 45
Fig 46
Fig 47
Note:
The blades are designed to be reversible, thus
extending their useful working life.
Use Genuine NUMATIC spare parts.
use
Replacement Blade Set (606261)