1205 Britannia Road E., Mississauga, ON L5N 5C8
Toll Free: 1-800-381-3210 Fax: 1-800-709-2896
H)
STEAM ONLY ACCESSORY TOOLS
The Jet Vac 2000 can be used as a steam only machine by fitting the steam only tools. When
fitting the steam only hose assembly (60 - 63) the steam vacuum command switch (12) must be
in the off position.
To steam clean choose the appropriate accessory (e.g. triangular brush (68), rectangular brush
(not shown), steam nozzle (65), detailing brush (66)). Connect the extension tubes (64) and
secure in place by setting the quick release latches (63). You may choose to use one or more
extension tubes. When using the large rectangular or triangular brushes, wrap a cloth around
them in order to maximize the cleaning effect and collection of dirt. Use the special clamps
provided on the tools to secure the cloth in place.
I)
REFILLING
When the water is depleted from the boiler, the red low water indicator (9) will light. It will then
be necessary to re-fill the boiler to continue use. Due to internal pressure it is not possible to
remove the valve cap (22). To release the internal pressure, turn the boiler switch OFF and turn
the steam command switch (26 or 62) ON. This will release the internal pressure. When the
pressure is reduced, the valve cap can be removed.
SAFETY DEVICES
The Jet Vac 2000 is fitted with 5 independent safety devices.
1)
pressure switch
2)
thermostat
3)
safety valve (22)
4)
temperature limiter
5)
12 Volt handle control switches
MAINTENANCE
After each use:
- flush hoses with clean water
- clean & dry all accessory tools
- wash and dry cleaning cloths
- remove vacuum tank (5), empty and clean
Note: the Jet Vac steam tools can be used to clean and sanitize the tank!
Occasionally:
- lightly lubricate joints and o-rings on accessory tools
After 500 hours:
- de-calcify boiler (see below)
Turn OFF machine and allow to cool completely, unscrew valve cap (22) and add 1 litre of
deliming solution with 1 litre of water. Allow to stand for at least 8 hours. Place a container
under the machine below the drain plug (23). Remove drain plug and allow solution to drain out.
Rinse by replacing plug and filling unit with fresh water. Drain again. Tighten drain plug.
Machine is ready to use again.