Nabis B24005 Скачать руководство пользователя страница 2

Important for new buildings/installations : before turning water 
on, ensure that one cold water tap is open so that dirt and 
loose particles in the pipe work are flushed through the tap 
(we also recommend to flush through the water supply pipe 
to the cistern).

A : PRE-INSTALLATION

B : INSTALLATION

Turn off water supply to cistern and remove cistern 
lid.

Flush the cistern and remove any loose dirt from 
inside the tank.

Disconnect and remove the existing inlet valve.

Insert correct filter restrictor into threaded tail.

1

2

3

1

Fit the filling valve. Ensure that the valve does not obstruct 
the flush mechanism. Do not overtighten the back nut

.

2

3

To adjust the water level, unclip the adjustment rod from the float.

4

B24007 B24011 

SIDE ENTRY INLET VALVE

!

!

If the filling valve touches the flush mechanism 
go to C: Rotation of Filling Valve.

Adjust the float basin. Check that the top of the float basin is set to 
waterline (Y) and internal overflow is 20mm above the water line.

5

6

Clip the adjustment rod on the float: check that the red arm is in 
low position before clipping the rod..

Turn ON water supply and check the water 
level is right.

7

C : ROTATION OF FILLING VALVE

Unscrew the grey nut below the red lever by 1 turn.

This allows the side entry inlet valve to be fitted inside the most  

compact cisterns.

1

While holding the red lever, rotate the filling valve into the 
appropriate position.

The float basin can touch the cistern walls.

2

Make sure the float moves freely after this 
adjustment has been carried out, or the inlet valve 
will not shut off or will be in shut off position.

!

If pressure < 1 bar (15 p.s.i.) :
cut here (gravity pressure / header tank)

Adjustment rod

Float

Float basin

Threaded tail

Red Arm

Filter restrictor

Rubber washer

Back nut

Overflow
top level

Float 
basin
top level

C

LE

VE

R  IDEA

A : PRE-INSTALLATION

B : INSTALLATION

Turn off water supply to cistern and remove cistern lid.

Flush the cistern and remove any loose dirt from inside 
the tank.

Disconnect and remove the existing inlet valve.

Insert correct filter restrictor into threaded tail.

1

2

3

1

B24009 9.5" FIXED

BOTTOM ENTRY INLET VALVE

If pressure < 1 bar (14 p.s.i.) : cut here (gravity pressure/header tank)

Fit the filling valve. Ensure that the valve does not obstruct the flush 
mechanism. Do not overtighten the back nut.

2

Important for new build / installations : before turning water on, ensure 
that one cold water tap is open so that dirt and loose particles in the 
pipe work are flushed through the tap (we also recommend to flush 
through the water supply pipe to the cistern before connection is made.

Connect water supply.

Turn on water supply. Allow the cistern to fill.
Adjust the water level :

A   -

  Turn off the water supply and flush the cistern

B   -

  Unclip the adjustment rod from the float 

5B

C   -

  Adjust the height of the float basin on the 

   body

 5C

D -

  Clip the adjustment rod on the float 

5D

 : check  that the red arm

is in low position before clipping the rod and the float is 
positioned inside the float basin.

3

4

5

E   -

  Check the water level is right

F   -

  Check that the high level of the float basin is lower than  

    the top level of the flushing valve overflow

.

6

   

Turn off water

   

Remove cover

   

Unscrew retaining nut

   

Remove diaphragm

 

Wash diaphragm and assemble in reverse order

 

Screw retaining nut and tighten. Ensure it is correctly positioned.

   

Assemble cover on nut and ensure it is clipped fully on nut

   

Turn on water supply and ensure the valve operates correctly

1

2

3

4

5

6

7

8

   

Turn off water

   

Disconnect the water supply

   

Remove filter restrictor

    see image ‘A’

   

Wash filter restrictor

   

Assemble filter restrictor into threaded tail

  

Connect water supply

   Turn on water supply

9

10

11

12

13

14

15

TROUBLESHOOTER

A

Diaphragm

25 mm minimum from internal
overflow to critical level (CL)
on inlete valve.

Adjustment rod

Float

Float basin

Body

Threaded tail

Rubber washer

Back nut

Filter restrictor