9 of 28
www.NabcoEntrances.com
AcusensorMInstallationManual
Rev 8-25-17
P/N C-00187
DN 1580
Figure 3
Install the Angled Sensor
CHAPTER 6: WIRE THE ACUSENSOR M
SECTION 6.1: Wire Swing Door with Monitoring (Opus Control)
DN 1578
7
6
5
4
3
2
1
10
9
8
11
12
13
14
ACUSENSOR M TO OPUS IN SWING DOOR WITH MONITORING
ACUSENSOR M
ACUSENSOR M
APROACH SIDE (ACTIVATION)
SWING SIDE (SAFETY)
RED
BLACK
BROWN
GREEN
V-00741
V-00741
ACUSENSOR M HARNESS
A-01292
ACUSENSOR M HARNESS
A-01292
YELLOW
GREY
RED
BLACK
BROWN
GREEN
YELLOW
GREY
P.N. A-00805
ON/OFF/HOLD-OPEN SWITCH
BLUE
WHITE
BLACK
RED
Off
Hold Open
On
Off