Additional Instructions for Cooling and Humidification
■
Use tee configuration with 2 Foggers or Super Foggers (4-way or cross is no longer
recommended because they cause high precipitation rates and prevent some of the water
from evaporating)
■
Recommended pressure is 60 PSI
■
Use high pressure LPD (Leak Prevention Device)
■
The foggers should be mounted as high as possible above the ground
■
The foggers should be installed perpendicular to the lateral line
■
Use anti-twist flexible PVC vinyl tube
■
Avoid contact between the droplets and any part of the greenhouse structure
Propagation and Germination
Using Dan Mister
■
Green Mist (7.9 GPH)
■
Green Mist Jr. (5.3 GPH)
■
Recommended working pressure 30 psi
■
Low pressure LPD