Using a starting address of DMX 1 on the 10-way PSU, this chart is an example of the Mozart fixture ID

 

  
 

 
 
 

 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DMX CH 

FIXTURE ID 

1 PIX 

DMX CH 

FIXTURE ID 

1 PIX 

DMX CH 

FIXTURE ID 

1 PIX 

10 

11 

12 

…continue as necessary 

Содержание Mozart ONE

Страница 1: ...Operation Manual Mozart ONE...

Страница 2: ...f the fixture Make sure there are no flammable materials close to the unit while operating Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse...

Страница 3: ...ppearance it is great to be used as a part of scenery Mozart has got 1 pixel which consists out of 6 RGBW CREE XM L LEDs beneath single lens It has a 1200 Hz refresh rate and 8bit colour dimming contr...

Страница 4: ...LED s RGBW Color Mode WHITE RGB RGBW Refresh rate 1200 HZ Intensity Control 8bit Control Mozart PSU DC power 48 V Power Consumption 20 W or 40 W in high power mode Cooling Convection IP Rating IP65 Op...

Страница 5: ...nected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum reco...

Страница 6: ...Fixture linking DMX 512 Controller RDM Mozart PSU Mozart PSU Amphenol M12 Amphenol M12 Up to 10 Mozart ONE fixtures Up to 5 Mozart ONE fixtures in High Power Mode Continue linking...

Страница 7: ...en only using RDM compliant lighting control device for example NA MasterFade Internal address set To keep the Mozart ONE as small as possible we have made power supply units for Mozart s which also i...

Страница 8: ...Set Address button The next addressing number will appear Repeat until the desired fixture number is shown on the tile Note Pressing the button once and not holding it will make the temperature infor...

Страница 9: ...chart is an example of the Mozart fixture ID DMX CH FIXTURE ID 1 PIX 1 2 3 R G B 1 4 5 6 R G B 2 7 8 9 R G B 3 DMX CH FIXTURE ID 1 PIX 1 W 1 2 W 2 3 W 3 DMX CH FIXTURE ID 1 PIX 1 2 3 4 R G B W 1 5 6...

Страница 10: ...e fixtures should be cleaned at least once a month Dust build up reduces light output performance and can cause overheating This can lead to reduced LED count life and increased mechanical wear Be sur...

Страница 11: ...ipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the sh...