TROUBLESHOOTING

MALFUNCTION

CAUSE

SOLUTION

• LEDs are off

• There is no
electricity on the
device

• LEDs are on
Continuously

• Changing detection
area in device

• Day light adjustment set to
night-time mode during daytime
operate
• LEDs are defected

• Power switch off or no electricity

• Fuse faulty

• Fuse switch off or fuse faulty

• Connection faulty.

• Continuously movement in
detection area
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.

• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.

• Control daylight setting and
re-adjust

• Call technical servise

• Check the electricity and power
on.
• Change the fuse.

• Check the fuse if necessary use
a new fuse.
• Check the connection cables.

• Check the detection area.

• Avert it is being detection.

• Change detection area, change
site of installation.

• Change site of installation or
keep the reasons away.

• Change site of installation.

“OFFERS ENERGY SAVING FEATURE’’

10970-10971

CEILING TYPE LED SENSORLIGHT

WITH HF MOTION SENSOR

SYSTEM COMPONENTS

(a) Polycarbonate Glass
(b) Protective cover
(c) Body
(d) Terminals
(e) Cable hole
(f) Mounting hole
(g) Polycarbonate glass and body connection point
(h) Screw holes

USAGE AREAS

• At the building entrances, stair vestibutes.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.

GENERAL SECURITY CAUTIONS

• Take out the original package and control if there is any damage of transportation
and general view of the product.
• Do not use the product at cross purposes.
• Do not supply high voltage.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist
electricians must install and apply.

CAUTIONS FOR INSTALLATION AND USAGE

• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Place the product horizontal to the ceiling.
• Use 6A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 15 - 20 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• Avoid mounting the detector close the objects as heaters, fans, refrigerators and ovens etc,
• It can cause the device operate inaccurately if there is moving objects in the coverage area.

(1) Detection Range Setting

SENSE adjustment is used to set the detection range. Also the movement can effect the detection
range. increase the sense adjustment will raise the detection range, also decrease the sense
adjustment will reduce the detection range.

(2) Time setting

Light ON time can be adjusted continuously from “10 sec. 

±

 1 sec. / 30 min. 

±

 1 min.” If you turn

the knob counter clockwise device will operate at minimum time. (10 seconds)

Control dial set to  - = Shortest time (10 sec. 

±

 1 sec.)

Control dial set to + =  Longest time (30 min. 

±

 1 min.)

(3) Daylight setting

The sensor’s response threshold can be infinitely varied from 2-2000 lux. If you turn the knob
counter clockwise device will operate at dark.

Control dial set +   = daylight operation approx. 2000 lux.
Control dial set  -   = night-time operation approx. 2 lux.

NOTE:

 Device will automatically make its own offset by checking environment for approximately

5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion
by this period.

GUARANTY

We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded. Claims under the warranty will only be
accepted if the unit is sent fully assembled and well packed complete with a brief description
of the fault, a receipt or invoice (date of purchase and dealer’s stamp) to the appropriate Service
Center.

KK-10970_10971_150417_EN_00

‹stanbul Deri Organize Sanayi Bölgesi Tufle Sok. No:8

M1-8 Özel Parsel 34953 Tuzla / ‹STANBUL - TÜRK‹YE

www.na-de.com.tr    •    [email protected]

DETECTING RANGE

(1)

(2)

(3)

Complies with ROHS Regulation Directive

2002/95/EC

TS EN

60669-2-1

TS EN

60598-2-1

(L) = Line conductor
(N) = Neutral conductor

(a)

(b)

(c)

(d)

(e)

(f)

(g)

(g)

(h)

(h)

(h)

SETTING

2.8 m.

9 m.

4.5 m.

4.5 m.

360°

Operating voltage
Detection angle
Mounting height
Detection range
Time settings
Lighting load
Emergency Lighting Load
Battery type
Battery opr. time
Protection class
Opr. temperature
Power consumption (Active / Stand-by)

SPECIFICATIONS

10971

-
-
-

19W / 1.6W

10970

40 lm

3.6V 1000 mAh Ni-Mh AAA

2 Hours

19W / 3W

230-240V~   50/60 Hz

360°

2.8 m.

3m / 9m. (adjustable)

10 sec. 

±

 1 sec. / 30 min. 

±

 1 min.

WW (3000K) : 860 lm / CW (6500K) : 911 lm

IP65       Class II

-20 °C ~ +40°C

Pass the power cable through the hole shown by (e). Then connect the  cable to the terminal
shown by (d). Fix the body (c) to ceiling as parallel shown by (f) with mounting screws.
Fix the glass (a) to the body through connection point shown by (g) by turning anticlockwise.
Macth the glass and body screw holes then fix the protective cover to the body with screw.