Ports – MAC Security – Learning 

 

The Learning tab allows the administrator to control the learning or locking modes for the ports.  ‗Locked‘ 
is the secure mode.  ‗Learning‘ builds an internal list of authorized MAC addresses based on an approved 
LAN.  When the current mode is ‗Learning‘, no ports are secured. 
 

 

 
In ‗Locked‘ mode, ‗Secured Ports‘ shows the ports that are presently secured.  

Note: when N-Ring and/or 

N-Link are used, the N-Ring/N-Link ports will not have MAC Security enabled. 

 

 

 
The Modify button allows the administrator to change the current mode.  When transitioning from 
‗Learning‘ to ‗Locked‘, the Address Resolution Logic (ARL) table represents the authorized MAC 
addresses, with the addition of any manually entered addresses (refer to Authorization List section below).  
Transitioning from ‗Locked‘ to ‗Learning‘, clears the ARL for all ports. 
 

 

 

Содержание 714FX6 Series

Страница 1: ...nd Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 1 of 158 714FX6 Managed Industrial Ethernet Switch User Manual Installa...

Страница 2: ...Server 23 LLDP 23 Port Security MAC Address Based 23 TROUBLESHOOTING 24 Web Software Configuration 25 Web Management 25 Web Management Home 26 Administration System 28 Administration SNMP 32 Administr...

Страница 3: ...ware Config 128 Help BPCL 129 Help User Management 130 Help Other 131 CLI Commands 132 Help 132 Logout 132 Show Add or Delete ARL Entries 133 Configuration Device Operations 134 Show or Set CIP Config...

Страница 4: ...EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 4 of 158 Example 6 Basic understanding of VLANs with Multicast Filtering 155 KEY SPECIFICATIONS 7...

Страница 5: ...426 7800 Revised 2011 07 21 Page 5 of 158 714FX6 Industrial Ethernet Switch Installation Guide The N TRON 714FX6 Industrial Ethernet Switch offers outstanding performance and ease of use It is ideally...

Страница 6: ...5 Copper Ports Six 100BaseFX Ports Where XX ST or SC YY 10 40 or 80 for Singlemode Blank for Multimode E Singlemode Blank Otherwise MANAGEMENT FEATURES SNMP v1 v2 v3 and Web Browser Management Configu...

Страница 7: ...connection only Do not use connect or disconnect unless area is known to be non hazardous Connection or disconnection in an explosive atmosphere could result in an explosion NTCD 128 Configuration De...

Страница 8: ...this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N Tron Corp be liable for any incidental special indirect or...

Страница 9: ...ON_Support n tron com ENVIRONMENTAL SAFETY WARNING The unit may become very hot to the touch in high temperature environments so extreme caution should be exercised in handling when energized The unit...

Страница 10: ...ING Explosion Hazard do not disconnect while circuit is live unless area is known to be non hazardous 4 WARNING Explosion Hazard do not replace the device unless power has been switched off or the are...

Страница 11: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 11 of 158 CLEANING Clean only with a damp cloth...

Страница 12: ...on the back of the unit against the DIN rail at a 15 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place To remove the unit from the 35mm industrial DIN ra...

Страница 13: ...LED lights when Power is supplied to the unit NOTE The RJ45 data port has two LEDs located on each connector The left LED indicates LINK status and the right LED indicates ACTIVITY LEDs The table bel...

Страница 14: ...nected to separate DC Voltage sources This device will draw current from both sources simultaneously Use 16 28 gauge wire when connecting to the power supply The Fault pins on the power connector can...

Страница 15: ...t the LNK LEDs are ON once the connection has been completed To connect any port to another device end node Switch or Repeater use a standard Category 5E straight through or crossover cable with a min...

Страница 16: ...ould be limited to 3 meters or less in length As an alternate users can run a drain wire shown in green lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM...

Страница 17: ...Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 17 of 158 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for...

Страница 18: ...the Command Line Interpreter CLI The USB connector is at the bottom of the 714FX6 USB Cable Connect the USB port of your PC and the Switch using a standard USB cable You will require a cable with a Ty...

Страница 19: ...defer nor do they monitor or react to receive activity as there is no contention for a shared medium in this mode Auto Negotiation In Auto Negotiation mode the port hardware detects the mode of operat...

Страница 20: ...rt is automatically removed from the Default VLAN when it is reconfigured to belong to another Virtual LAN because that is the most common operation But if desired the port can be included in VLAN 1 b...

Страница 21: ...e detected on bridge ports The user can also manually configure bridge ports to use the older STP when desired SNMP Traps The 714FX6 Series switch supports up to 5 SNMP Trap Stations to which SNMP Tra...

Страница 22: ...nd the Standby Coupler link will block network traffic When a problem is detected on the Primary Coupler link the Primary Coupler link will block network traffic and the Standby Coupler link will forw...

Страница 23: ...n an IP assignment IP assignments can be set up as a dynamic range of IP addresses available to any client device or specific IP addresses based on the clients MAC address Client ID Option 61 or Relay...

Страница 24: ...CC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and...

Страница 25: ...00 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 25 of 158 Web Software Configuration Web Management Enter the switch s IP address in any web browser and login to the web manageme...

Страница 26: ...the left hand side of the screen there is a list of configurable settings that the 714FX6 Series switch will support This section of the manual will go through each and every choice listed on the lef...

Страница 27: ...age 27 of 158 Web Management Menu Structure To the left there is a menu which is shown fully opened below The pages opened by each of the individual selections are described in the rest of this sectio...

Страница 28: ...ts the total time count This time has elapsed since the switch was turned ON or RESET Name It shows the name of the product which allows alphanumeric and special characters _ only Contact The person t...

Страница 29: ...ollowing information is added Client ID Option used by DHCP clients to specify their unique identifier The identifier may be the MAC address switch name or entered as a text string or hex characters F...

Страница 30: ...change the switch s IP Configuration Client ID IP Address Subnet Mask Gateway Name Contact information and the Location of the switch through the web management features depending on the IP Configura...

Страница 31: ...tion mode is set to DHCP and the Fallback IP address is changed from the default IP address then the switch will use the Fallback addresses if the IP configuration isn t received from a DHCP server in...

Страница 32: ...of IP Addresses that act as SNMP Traps The Read Only Read Write and Trap Community Names are also shown here By selecting the Modify button you will be able to change any of the fields listed This al...

Страница 33: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 33 of 158 Administration SNMP Continued...

Страница 34: ...notification may consist of any combination of the options Show Web Show LED and Contact Power signal faults consist of V1 and V2 N Ring Manager signal faults consist of Broken Partial Break Low Parti...

Страница 35: ...00 Revised 2011 07 21 Page 35 of 158 Following the Modify button the administrator will see a list of configurable fields for the Fault configuration Once these fields are filled in to meet the needs...

Страница 36: ...Broadcast Ms The amount of time the DHCP server will delay processing a broadcast message Server ID Descriptive name of the DHCP server Profile Name Descriptive name of the network profile Address Poo...

Страница 37: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 37 of 158 DHCP Server Setup Profiles Continued...

Страница 38: ...ddresses for requesting clients The following information is required Network Profile An existing network profile to which the IP map applies Low IP The starting IP address of a range High IP The endi...

Страница 39: ...Switch Model List of N TRON models that support this feature Remote ID A unique identifier that designates the N TRON relay agent switch Add Checkbox used to add an IP map for the corresponding port...

Страница 40: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 40 of 158 DHCP Server Setup IP Maps Continued...

Страница 41: ...the IP map applies Relay Agent Type Should be set to Generic Port Count The number of ports on the particular relay agent switch Add Checkbox used to add an IP map for the corresponding port Port No T...

Страница 42: ...of mapping is used to create a static IP address for an individual client The following information is required Network Profile An existing network profile to which the IP map applies IP The static IP...

Страница 43: ...e The profile applied to the binding entry Binding Identifier The client associated with the binding entry Client Hardware Address MAC The client s MAC address Client IP Address The actual IP address...

Страница 44: ...2011 07 21 Page 44 of 158 DHCP Relay Local IP Setup The Setup tab under the DHCP Relay Local IP category shows the current state of the relay agent By selecting the Modify button you can configure ge...

Страница 45: ...e of the port Relay Status The selection to designate whether the port will perform relay agent functionality The choices are Disabled The port will function without relay agent processing Enabled The...

Страница 46: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 46 of 158 DHCP Relay Local IP Setup Continued...

Страница 47: ...This prevents excessive Notifications if someone toggles between Disabled and Enabled on LLDP Port settings Default 2 Seconds Notification Interval Specifies the interval between successive Notificati...

Страница 48: ...he port on the local switch Transmit Enables or Disables LLDP Transmission on the switch Receive Enables or Disables Receiving of LLDP Frames from neighbor switches Allow Management Data Allow the Tra...

Страница 49: ...r port is four Port Name The name of the local port on which the neighbor information was received Neighbor MAC MAC address of neighbor switch Corresponds to the LLDP Chassis ID TLV Neighbor IP IP add...

Страница 50: ...Frames sent out from the local switch Received Frames Total number of LLDP frames received by the local switch Discarded Frames The total number of frames discarded due to incorrect TLV s in frame Er...

Страница 51: ...field displays the port priority status of each port When enabled for a port all frames received on that port will be forced to the highest priority queue regardless of Default Priority setting or pr...

Страница 52: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 52 of 158 Ports Configuration Continued...

Страница 53: ...53 of 158 Ports Configuration Continued The User can click on the Port Number to configure each port individually This will allow the user to change the port s settings for the following fields which...

Страница 54: ...LAN When the current mode is Learning no ports are secured In Locked mode Secured Ports shows the ports that are presently secured Note when N Ring and or N Link are used the N Ring N Link ports will...

Страница 55: ...uthorized ports Selecting Modify displays the MAC Authorization Configuration page which allows the administrator to add new entries delete existing entries or edit authorized ports of existing entrie...

Страница 56: ...ombination of MAC address VLAN and port Only the first occurrence of the intruder is listed The log is ordered by most recent first based on the system time The maximum number of entries is 100 If mor...

Страница 57: ...ng A mirroring port is a dedicated port that is configured to receive the copies of Ethernet frames that are being transmitted out and also being received in from any other port that is being monitore...

Страница 58: ...800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 58 of 158 Ports Mirroring Continued Following the Modify button you can enable the status of port mirroring and select source por...

Страница 59: ...can be either Enabled Disabled By selecting the Modify button you can select a trunk group Note RSTP must be disabled in order to use the Trunking feature Two ports of the same speed can constitute a...

Страница 60: ...f Service in the TQ decision When enabled the DSCP TOS is included when evaluating traffic priority Include 802 1p This field displays the status of whether or not to include the IEEE 802 1p COS Class...

Страница 61: ...011 07 21 Page 61 of 158 Ports QOS Continued Following the Modify button the administrator can independently configure the ports for different QOS functionality Once these fields are filled in to meet...

Страница 62: ...atistics tab under the Statistics category displays a list of MIB parameters Each port has a separate counter for each parameter This gives users the ability to see what kind of packets are going over...

Страница 63: ...e Ports Utilization tab under the Statistics category shows all the ports on the switch and will display a bar graph showing the percentage of bandwidth being used These figures and bars are for a gen...

Страница 64: ...ring Specifies whether or not to filter out ingress frames when a VID violation is detected Discard Non Tagged for Ports Specifies whether or not non tagged ingress frames are dropped by the selected...

Страница 65: ...e of the VLAN which accepts alphanumeric and special characters _ only Allow Management Specifies whether or not all ports in this VLAN are management ports Change PVID of Member Ports Specifies wheth...

Страница 66: ...gory will display the currently configured Aging Time This page allows users to modify this variable to meet their needs After selecting the Modify button the user will be presented with a page that a...

Страница 67: ...ging category will display a list of MAC addresses that are associated with each respective port number This can be used to statically assign a MAC address access to a single port on the switch Follow...

Страница 68: ...es Continued Once a static MAC address has been added it will be displayed in a list on the main page under Unicast MACs tab Following the Remove button on the example above an administrator can selec...

Страница 69: ...he Add button on the page above the administrator must enter a valid Multicast Group Address and associate it with a port number or list on the switch Once the administrator clicks on the Add button t...

Страница 70: ...of Multicast Group Addresses that are configured on the switch Using the pull down menu the administrator should select the desired address to be removed Then click on the Remove button at the bottom...

Страница 71: ...ew MAC by Port shows the MAC for the device found on each port and the IP for the MAC presented if available If more than one device is on that port then the lowest alphanumeric of those MAC addresses...

Страница 72: ...s are underlined and validated A validated IP for that MAC is presented in green and if validation fails the IP will be red and underlined Note that some devices do not have an IP Address and that som...

Страница 73: ...Configuration The Configuration tab under the RSTP category will display the RSTP information for the first VLAN Using the pull down menu at the top of the page an administrator can choose which VLAN...

Страница 74: ...Delay Max Age Priority and the Status of RSTP on that VLAN The administrator or user can see the current RSTP status of the ports on that VLAN by clicking on the here link to view RSTP Port Configurat...

Страница 75: ...tion at VLAN the administrator or user can see the current RSTP status of the ports on that VLAN This will show information such as the Path Cost and the Port State If the switch sees a redundant path...

Страница 76: ...0 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 76 of 158 RSTP Configuration Continued If the administrator selects one of the ports on the previous screen he or she can change th...

Страница 77: ...on tab under the IGMP category will display the IGMP basic configuration settings By default IGMP is enabled Following the Modify button the administrator will see a list of configurable fields for th...

Страница 78: ...el 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 78 of 158 IGMP Configuration Continued The IGMP Status pull down allows the user to enable or disable IGMP completely The Query Mode pull down...

Страница 79: ...Revised 2011 07 21 Page 79 of 158 IGMP Configuration Continued The Router Mode pull down allows the user to choose router mode Auto allows for dynamically detected and manually set router ports Manual...

Страница 80: ...ge 80 of 158 IGMP Show Group and Show Router The Show Groups tab under the IGMP category will display a list of IGMP groups based on the Group IP and the port number that it is associated with The Sho...

Страница 81: ...s setting KNOWN is known from dynamic IGMP Snooping operations The factory default is that the Router Multicast Data Filter is enabled for all ports so any router ports do NOT get DATA frames with KNO...

Страница 82: ...r Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 82 of 158 IGMP RFilter Continued Modifying rfilter port settin...

Страница 83: ...y will display two basic variables for N View the status and the interval between packets Following the Modify button on the above example the administrator can modify the variable to change the frequ...

Страница 84: ...76 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 84 of 158 N View Ports The Ports tab under the N View category will display a list of all the configured ports on the 714FX6 unit alon...

Страница 85: ...Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 85 of 158 N View Ports Continued Following the Modify button on the above example the administrator can modify these two variables to enable o...

Страница 86: ...N Ring Member and in either case N Ring status includes for example Switch is currently using N Ring Aging Time 20 Seconds Once these fields are filled in to meet the needs of the administrator s net...

Страница 87: ...876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 87 of 158 N Ring Configuration Continued The N Ring Mode is one of three as below If N Ring Mode is Manager then a pull down allows s...

Страница 88: ...ons as well as traffic flow N Ring only makes minimal changes It is up to the administrator to ensure that VLANs are configured correctly on the N Ring manager and all N Ring members 2 When the N Ring...

Страница 89: ...t of time to wait in milliseconds before requesting initial sign on information from ring members The default is 1000 Sign On Match Packets The number of times the switch count must match before start...

Страница 90: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 90 of 158 N Ring Advanced Configuration Continued...

Страница 91: ...07 21 Page 91 of 158 N Ring Status The Status tab under the N Ring category will display the N Ring status Below is an example of N Ring Status from a switch in defaults N Ring Auto Member that is no...

Страница 92: ...t Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 92 of 158 N Ring Status Continued Below is an example of N Ring Status from an N Ring Ma...

Страница 93: ...N Ring Status Continued Below is an example of N Ring Status from an N Ring Manager with a faulted N Ring The red fields on the N Ring Map show problems Ports that are red indicate that the port is n...

Страница 94: ...break in just one fiber in a duplex channel fiber pair The screenshot below shows N Ring Manager Status when a Higher N Ring Port TX2 or FX2 is not receiving self health frames all the way around the...

Страница 95: ...Link Configuration Example N Rng Manager N Ring Auto Member N Link Slave N Ring Member N Link Master N Ring Member Partner Link N Ring Segment Control Link N Ring Auto Member N Rng Manager N Link Cou...

Страница 96: ...e N Link Slave and both Coupler switches will auto detect any needed configuration If not using default configuration choices the administrator may also need to configure the Default Coupler port on t...

Страница 97: ...de and will use TX4 as the Default Coupler port Following the Modify button on the above example the administrator will see a list of configurable fields for the N Link configuration as below The port...

Страница 98: ...iguration Continued The N Link Mode is one of two choices as below If N Link mode is Master then the administrator must configure the Control Port default TX3 and the Primary Coupler Port default TX4...

Страница 99: ...d Slave Partner ports Use of media converters or other switches is not supported This port will be detected automatically Coupler Port The port being used to establish a redundant path for ethernet da...

Страница 100: ...com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 100 of 158 N Link Status Continued Below is an example of N Link Status from an N Link Coupler switch Below is an...

Страница 101: ...6 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 101 of 158 N Link Status Continued Below is an example of N Link Status from an N Link Slave switch Below is an example of N Link Statu...

Страница 102: ...7700 Fax 203 426 7800 Revised 2011 07 21 Page 102 of 158 N Link Status Continued Below is an example of N Link Status from an N Link Master and Slave where the Standby Coupler link is broken Below is...

Страница 103: ...MD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 103 of 158 N Link Status Continued Below is an example of N Link Status from an N Link Master and...

Страница 104: ...e Switch Default Enabled Multicast RPI The minimum Requested Packet Interval for Class 1 multicast connections in milliseconds Requests for less than this value will be rejected Default 1 second Unica...

Страница 105: ...is N Tron s ODVA EtherNet IP Vendor ID 1006 Device Type The ODVA Device Type is Communications Adapter 0x0C hex Major Revision The Major Revision of the CIP implementation Minor Revision The Minor Re...

Страница 106: ...ey need to reload their custom configurations at a later time Administrators can also download an Image or Boot Image file to the switch via TFTP allowing them to update the firmware in the field with...

Страница 107: ...3 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 107 of 158 Support Web Site and E mail If at any point in time you get confused or would like additional support directly from N Tron you may visit...

Страница 108: ...t Count Limit Configuration The BPCL link will display all the ports that are installed in the 714FX6 Series unit and will list the BPCL Percentage for each port BPCL defaults to 3 for 10 100 ports A...

Страница 109: ...l display a list of all the users who have access to the management features of the switch and their access permissions Following the Add button on the above example the administrator can add another...

Страница 110: ...ample the administrator can remove a user by entering in the user s name and clicking the Remove button A page should follow indicating that the user was successfully removed from the list Note There...

Страница 111: ...the switch Here a user or administrator can see a graphical depiction of the 714FX6 series switch Ports that are linked will appear in green while ports that are not linked will appear in black The e...

Страница 112: ...cycle The Save button will save all current changes to the configuration for use after the next power cycle The Reset button will discard all unsaved changes reset the switch and load the most recentl...

Страница 113: ...Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 113 of 158 If a Configuration Device is present that is present...

Страница 114: ...vised 2011 07 21 Page 114 of 158 Help Overview When the Help link is clicked on you will see the Overview page that will have some basic definitions and more specific choices at the top of the screen...

Страница 115: ...426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 115 of 158 Help Administration Following the Administration link on the help page the administrator or user can see some information regarding the co...

Страница 116: ...4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 116 of 158 Help DHCP Following the DHCP link on the help page the administrator or user can see some information regarding the configurat...

Страница 117: ...76 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 117 of 158 Help LLDP Following the LLDP link on the help page the administrator or user can see some information regarding the configu...

Страница 118: ...4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 118 of 158 Help Ports Following the Ports link on the help page the administrator or user can see some information regarding the configu...

Страница 119: ...el 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 119 of 158 Help Statistics Following the Statistics link on the help page the administrator or user can see some information regarding the conf...

Страница 120: ...76 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 120 of 158 Help VLAN Following the VLAN link on the help page the administrator or user can see some information regarding the configu...

Страница 121: ...4 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 121 of 158 Help Bridging Following the Bridging link on the help page the administrator or user can see some information regarding the confi...

Страница 122: ...76 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 122 of 158 Help RSTP Following the RSTP link on the help page the administrator or user can see some information regarding the configu...

Страница 123: ...76 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 123 of 158 Help IGMP Following the IGMP link on the help page the administrator or user can see some information regarding the configu...

Страница 124: ...4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 124 of 158 Help N View Following the N View link on the help page the administrator or user can see some information regarding the config...

Страница 125: ...4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 125 of 158 Help N Ring Following the N Ring link on the help page the administrator or user can see some information regarding the config...

Страница 126: ...4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 126 of 158 Help N Link Following the N Link link on the help page the administrator or user can see some information regarding the config...

Страница 127: ...876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 127 of 158 Help CIP Following the CIP link on the help page the administrator or user can see some information regarding the configur...

Страница 128: ...26 7700 Fax 203 426 7800 Revised 2011 07 21 Page 128 of 158 Help Firmware Config Following the Firmware Config link on the help page the administrator or user can see some information regarding the co...

Страница 129: ...76 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 129 of 158 Help BPCL Following the BPCL link on the help page the administrator or user can see some information regarding the configu...

Страница 130: ...26 7700 Fax 203 426 7800 Revised 2011 07 21 Page 130 of 158 Help User Management Following the User Management link on the help page the administrator or user can see some information regarding the co...

Страница 131: ...00 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 131 of 158 Help Other Following the Other link on the help page the administrator or user can see some information regarding other...

Страница 132: ...d will be listed If is preceded by another the usage and description of this command will be displayed Syntax cmd Parameters cmd The command for which to get help Examples N TRON Admin The above comma...

Страница 133: ...table showmct Show entire ARL MCT Multicast Index table delete Delete MAC address add Add MAC address mac MAC Address port Port Number cpu 1 Send to CPU also static 1 This is a static address 0 Non S...

Страница 134: ...Configuration device model number Valid values are 1 At32K 2 At64K and 3 card Compare Compare the configuration of the switch to the configuration device Erase Erase the switch configuration on the co...

Страница 135: ...RON Admin cip show CIP Configuration Status Enabled EthIp Interval 10 ms Cache Interval 2000 ms Identity Information Product Name N TRON 714FX6 Vendor 1006 N TRON Device Type 0x0C Communications Adapt...

Страница 136: ...nt user names and passwords y n y NOTES Show or Set IGMP Configuration Command Name igmp Description Show or set IGMP configuration If no parameters are specified this command will show the IGMP confi...

Страница 137: ...led dp portno Set the destination port number for mirrored frames tx portlist Set the source ports to mirror frames that are transmitted rx portlist Set the source ports to mirror frames that are rece...

Страница 138: ...r or use to list available port sets Examples N TRON Admin nring show N Ring Mode Auto Member Aging Time 20 N TRON Admin nring ports ID Port Set 1 TX1 TX2 2 FX1 FX2 N TRON Admin nring mode m ports 2 D...

Страница 139: ...stics and continue type Space To stop type Control C n count Number of echo requests to send w timeout Timeout in milliseconds to wait for each reply Example N TRON Admin ping 192 168 1 119 N TRON Adm...

Страница 140: ...0 7 dscp state Set the DSCP Priority for the port to e nabled or d isabled 8021p state Set the 802 1p Priority for the port to e nabled or d isabled pvid Set the VLAN ID for the port The range is 1 4...

Страница 141: ...Syntax snmp show ro name rw name trap name Parameters show Show configuration ro name Set the Authorized Community Name for SNMP Get requests rw name Set the Authorized Community Name for SNMP Set req...

Страница 142: ...one N TRON Admin syserr clear Last System Error Cleared Notes Show System Information Command Name Sysinfo Description Show system information Syntax Sysinfo Parameters None Example N TRON Admin sysin...

Страница 143: ...ig mode and IP fallback s static_subnet_mask Static sub net mask for static config mode and IP fallback g static_gateway Static gateway address for static config mode and IP fallback Example N TRON Ad...

Страница 144: ...abel Set the switch name browser state Set the browser access status to e nabled or d isabled Examples N TRON Admin system name Private switch browser disabled IP Configuration Static IP Address 192 1...

Страница 145: ...ctory default VLAN configuration Clicking on the Modify button allows one to add a new VLAN When creating a new VLAN a numeric ID is required Name is entered Note that N Ring VLAN is a reserved name w...

Страница 146: ...rt Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 146 of 158 The result of add is a New VLAN In this case it does not overlap the...

Страница 147: ...l apply the static multicast address to the lowest VLAN ID that is associated with one of the ports assigned to the static multicast address If the lowest VLAN ID contains all the ports assigned to th...

Страница 148: ...w walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 148 of 158 And the New VLAN is removed Note that the new configuration of the switch must be saved if t...

Страница 149: ...For Sales and Support Contact Walker EMD www walkeremd com Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 Revised 2011 07 21 Page 149 of 158...

Страница 150: ...groups such as Office LANs Controls Systems and IP Cameras When used properly it will effectively isolate two or more groups from each other in a logical manner This means that Broadcast Multicast an...

Страница 151: ...rt Tagged VID in packet Destination Address Transmitting Port s Notes TX1 Untagged MAC on port TX2 Packet Discarded TX1 VID 2 MAC on port TX2 TX2 Unicast Traffic TX1 VID 4 MAC on port TX2 Packet Disca...

Страница 152: ...packet Destination Address Transmitting Port s Notes TX1 Untagged MAC on port TX2 TX2 Adds VID 2 to packet TX1 VID 2 MAC on port TX2 TX2 Unicast Traffic TX1 VID 4 MAC on port TX2 Packet Discarded TX1...

Страница 153: ...X2 Unicast Traffic TX1 Untagged MAC on port TX3 TX3 Adds VID 2 in the packet TX1 VID 4 MAC on port TX2 Packet Discarded TX1 VID 4 MAC on port TX3 Packet Discarded TX1 VID 2 MAC on port TX2 TX2 Strips...

Страница 154: ...rips VID off packet TX1 VID 4 Unknown MAC TX2 Strips VID off packet Floods VLAN 4 TX2 Untagged MAC on port TX1 VID 2 TX1 Unicast Traffic TX2 Untagged MAC on port TX5 VID 2 TX5 Unicast Traffic TX2 VID...

Страница 155: ...go back out the port it came in on TX2 Untagged 01 00 00 00 00 02 TX1 TX3 TX8 Goes to ports TX1 TX3 TX8 TX3 Untagged 01 00 00 00 00 01 TX2 TX4 TX8 Goes to ports TX2 TX4 TX8 TX6 Untagged 01 00 00 00 0...

Страница 156: ...Input Ripple Less than 100 mV N TRON Power Supply NTPS 24 1 3 1 3 Amp 24VDC Environmental Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 5 to 95 Non Condensing...

Страница 157: ...Bm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength Min Max 1310nm 1310nm 1310nm 1550nm Multimode Fiber Optic Cable Singlemode Fiber Optic Cable Regulatory Approvals EMI ANSI C63...

Страница 158: ...ll charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE R...

Отзывы: