Configuration – Save or Reset 
 

The Configuration section of the web management gives an administrator the ability to save a running 
configuration into the NVRAM.  This step is needed in order for the switch to remember any changes after a 
power cycle.   
 
The Reset Configuration button will reload N-Tron‟s factory default configuration settings.  Doing so will 
re-configure the 7000 Series switch to factory defaults. 
 
In many cases it is desirable to restore factory defaults but retain the IP, Slot Configuration, Subnet Mask, 
and Gateway Address settings.  A choice is provided to this end. 
 

Содержание 7014TX

Страница 1: ...Revised 2011 07 21 page 1 of 152 7014 Series Industrial Gigabit Ethernet Switch User Manual Installation Guide...

Страница 2: ...30 Ports Intrusion Log 32 Ports Mirroring 33 Ports Trunking 34 Statistics Port Statistics 36 Statistics Port Utilization 37 VLAN Ingress Filter 38 VLAN Port Based 40 Bridging Aging Time 44 Bridging Un...

Страница 3: ...ontact 103 Set System Contact 104 Get System Location 104 Set System Location 104 Get System Uptime 104 Get Number of Ports present in the System 104 Set System Gigabit 104 Set IP Address of the SNMP...

Страница 4: ...tiation State 115 Set Priority State 115 Set Flow Control 116 Set Name 116 Set PVID 116 Set Backpressure 116 Set Intruderstate 116 Set Priority Level 117 Show Configuration 117 Show Intruders 117 Show...

Страница 5: ...IGMP Related Commands 132 Enable IGMP 132 Disable IGMP 132 Show IGMP config 132 Show IGMP group 132 Show IGMP router 133 Set IGMP query mode 133 Set IGMP router port 133 Set IGMP router mode 133 Show...

Страница 6: ...143 Set RSTP Port Priority 144 Get RSTP Port Priority 144 Broadcast Packet Count Limit Commands 145 Get the Broadcast Packet Count Limit for one port 145 Get the Broadcast Packet Count Limit for all...

Страница 7: ...ls only Extended Environmental Specifications Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches Store Forward Technology Pl...

Страница 8: ...of errors or omissions in this manual or the information contained herein Warning Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unautho...

Страница 9: ...e permanent damage to the unit and void the warranty 7014 Series Hazardous Location Installation Requirements 1 WARNING Explosion Hazard do not disconnect while circuit is live unless area is known to...

Страница 10: ...owing warning before beginning the installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous g...

Страница 11: ...ng the switch in the vertical position you must orientate the power connector to the top as shown above for proper ventilation To remove the unit from the 35mm din rail place a flat head screwdriver i...

Страница 12: ...en LED lights when Power is supplied to the unit NOTE The RJ45 data port has two LED s located on each connector The left LED indicates LINK status and the right LED indicates ACTIVITY LED s The table...

Страница 13: ...lock power plug is 0 5 Nm 0 368 Pound Foot Verify the Power LED stays ON GREEN Note Only 1 power supply must be connected to power for minimal operation For redundant power operation V1 and V2 inputs...

Страница 14: ...use a standard Category 5E straight through or crossover cable with a minimum length of one meter and a maximum length of 100 meters N Tron recommends the use of pre manufactured Cat5E cables to ensur...

Страница 15: ...rnate users can run a drain wire lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to...

Страница 16: ...Revised 2011 07 21 page 16 of 152 CAT5 CABLE CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications...

Страница 17: ...able with a 9 pin or 25 pin sub D female connector for the PC end and a 9 pin male sub D connector for the 7014 Series end The following table shows the pin out and the connections for both types of c...

Страница 18: ...using point to point media dedicated channel Full duplex operation does not require that transmitters defer nor do they monitor or react to receive activity as there is no contention for a shared medi...

Страница 19: ...support devices on the network that do not support VLAN Tagged packets The administrator can also set up the ports to discard any packets that are tagged or to discard any packets that are untagged b...

Страница 20: ...as interested in receiving the originating computer s content Multicasting can be used to transmit only to an audience that has joined and not left a multicast group membership IGMP version 2 is forma...

Страница 21: ...ent generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this dev...

Страница 22: ...1 07 21 page 22 of 152 Web Software Configuration Web Management Enter the switch s IP address in any web browser and login to the web management feature of the 7014 Series Default User Name admin Pas...

Страница 23: ...able settings that the 7014 Series switch will support This section of the manual will go through each and every choice listed on the left hand side of the screen and explain how to configure those se...

Страница 24: ...here is a menu which is shown fully opened below The pages opened by each of the individual selections are described in the rest of this section The use of each of these pages is also described in thi...

Страница 25: ...ton you will be able to change the switch s IP Address Subnet Mask Default Gateway Name Contact information and the Location of the switch through the web management features It is recommended to chan...

Страница 26: ...es are also shown here By selecting the modify button you will be able to change any of the fields listed This allows the user to set an IP address for an SNMP Trap or change the Community Names Syste...

Страница 27: ...repeat the steps listed above 2 Validation of the configuration and each physical cable segment may be obtained by using N ViewOPC Server software The software is freely distributed on the ProductCD...

Страница 28: ...y will show a detailed overview of all the active ports on the switch The overview will display the following information Port Number Port Name Admin Status Link Status Auto Negotiation State Port Spe...

Страница 29: ...ntinued The User can click on the Port Number to configure each port individually This will allow the user to change the port s settings for the following fields Admin Status Speed and Duplex Flow Con...

Страница 30: ...Revised 2011 07 21 page 30 of 152 Ports Security The Security tab under the Ports category will show a list of all the active ports and the security Lock State for each port...

Страница 31: ...ed Administrators can change the Port Security by a per port basis If the Port is enabled through this the port will be locked and will only allow known MAC addresses to communicate through the port U...

Страница 32: ...The Intrusion Log tab under the Ports category will show a list of intruders along with their MAC addresses The log will show what Port the intruder attempted to access your network on and log the sys...

Страница 33: ...monitored The Mirroring tab under the Ports category displays the status including the list of Source Ports and the Destination Port that the Sources are being mirrored to Following the Configure butt...

Страница 34: ...Trunking Feature A maximum of 4 ports of the same speed can constitute a valid trunk Only 1 Trunk per switch can be created All trunk ports must be at the same speed and duplex mode If a port is not...

Страница 35: ...for the Trunk ID and what the Trunk State is NOTE RSTP must be disabled in order to use the Trunking Feature A maximum of 4 ports of the same speed can constitute a valid trunk Only 1 Trunk per switch...

Страница 36: ...of MIB Parameters Each port has a separate counter for each parameter This gives users the ability to see what kind of packets are going over which ports At the bottom of each page for each port ther...

Страница 37: ...e Statistics category shows all the ports on the switch and will display a bar graph showing the percentage of bandwidth being used These figures and bars are for a general feeling of what the bandwid...

Страница 38: ...tegory shows all the Ingress Filter Rule enabled or disabled state for each port Ingress Filtering can be Enabled or Disabled for each port If enabled received frames will be discarded if the frame s...

Страница 39: ...ct the port number from the pull down menu that you wish to modify and then choose to either enable or disable the Ingress Filter Rule NOTE The Ingress Filter will automatically be turned on for respe...

Страница 40: ...shows all the VLANs that are configured on the switch and details about the VLANs such as port numbers and tagged VLAN settings To add a VLAN simply click on the Add button on the page above and fill...

Страница 41: ...y be enabled on one of the VLANs that is overlapping others RSTP can not be implemented on a VLAN that contains other VLANs within that one Changing anything on a VLAN will turn on RSTP on all VLANs a...

Страница 42: ...ill load the page where the user can enter the VLAN ID that he or she wishes to delete See VLAN Configuration Examples section Note 1 When implementing overlapping VLANs RSTP can only be enabled on on...

Страница 43: ...return to the default VLAN Users should keep this in mind when removing VLANs and may need to manually change the PVIDs for any affected ports See VLAN Configuration Examples section Note 1 When impl...

Страница 44: ...g category will display the currently configured Aging Time This page allows users to modify this variable to meet their needs After selecting the Modify button the user will be presented with a page...

Страница 45: ...used to statically assign a MAC address access to a single port on the switch Following the Add button on the page above the administrator must enter a valid MAC address and associate it with a port...

Страница 46: ...s Continued Following the Delete button on the page above an administrator can select a static MAC address from the list using a pull down menu After selecting the MAC address the administrator needs...

Страница 47: ...ator must enter a valid Multicast Group Address and associate it with a port number or list on the switch Once the administrator clicks on the Update button the changes will take effect instantly Note...

Страница 48: ...switch Using the pull down menu the administrator should select the desired port to be removed Then click on the Delete button at the bottom of the page Note If there are multiple ports on different V...

Страница 49: ...gure the bridge by clicking on the Configuration button in the middle of the page The configuration screen for the VLAN that was previously selected will look like the example below Here the administr...

Страница 50: ...nt RSTP status of the ports on that VLAN This will show information such as the Path Cost and the Port State If the switch sees a redundant path it will put the port with the highest Path Cost into Bl...

Страница 51: ...page 51 of 152 RSTP RSTP Configuration Continued If the administrator selects one of the ports on the previous screen he or she can change the Port s Path Cost Port s Priority and the status of Admin...

Страница 52: ...ation settings By default IGMP is enabled Following the Modify button on the previous page the administrator will see a list of configurable fields for the IGMP configuration Once these fields are fil...

Страница 53: ...53 of 152 IGMP Configuration continued The IGMP Status pull down allows the user to enable or disable IGMP completely The Query Mode pull down allows the user to set query mode for Automatic the defau...

Страница 54: ...nued The Router Mode pull down allows the user to choose router mode Auto allows for dynamically detected and manually set router ports Manual allows only for manually set router ports None allows no...

Страница 55: ...oup tab under the IGMP category will display a list of IGMP groups based on the Group IP and the port number that it is associated with The Show Router tab under the IGMP category will display a list...

Страница 56: ...ions The factory default is that the Router Multicast Data Filter is enabled for all ports so any router ports do NOT get DATA frames with KNOWN multicast destination addresses unless a join to a spec...

Страница 57: ...Revised 2011 07 21 page 57 of 152 IGMP Rfilter Continued Modifying rfilter port settings...

Страница 58: ...nd the interval between packets Following the Modify button on the above example the administrator can modify the variable to change the frequency with which N View reports information Increasing the...

Страница 59: ...21 page 59 of 152 N View Ports The Ports tab under the N View category will display a list of all the configured ports on the 7014 unit along with the ports transmitting multicast packets and MIB sta...

Страница 60: ...0 of 152 N View Ports Continued Following the Modify button on the previous example the administrator can modify these two variables to enable or disable multicast out of the port and if MIB stats are...

Страница 61: ...ble fields for the N Ring configuration as below The N Ring Agingtime has a default of 20 seconds and is separate from the Bridging Aging Time N Ring Aging time is used for the whole switch if the swi...

Страница 62: ...tly in an active N Ring 4 Any one 7014 can only participate in one N Ring 5 N Ring copper ports must be run at 100Mb full duplex including the default autonegotiate as long as all switches in the ring...

Страница 63: ...Revised 2011 07 21 page 63 of 152...

Страница 64: ...Revised 2011 07 21 page 64 of 152 N Ring Configuration continued If N Ring Mode is Manager then a pull down allows selection of displaying N Ring Summary Status on all web pages or on N Ring pages onl...

Страница 65: ...s It is up to the administrator to ensure that VLANs are configured correctly on the N Ring manager and all N Ring members 1 2 When the N Ring manager and all N Ring Members are in defaults changing t...

Страница 66: ...he N Ring category will display the N Ring status Below is an example of N Ring Status from a switch in defaults N Ring Auto Member that is not an N Ring Manager and has not become an Active N Ring Me...

Страница 67: ...255 255 255 0 N TRON Switch GB2 GB1 3 00 07 af ff ef 80 192 168 1 221 255 255 255 0 N TRON Switch GB2 GB1 4 00 07 af ff e4 c0 192 168 1 241 255 255 255 0 N TRON Switch GB2 GB1 5 00 07 af ff d5 e0 192...

Страница 68: ...92 168 1 227 255 255 255 0 N TRON Switch GB2 GB1 1 00 07 af ff ef 60 192 168 1 224 255 255 255 0 N TRON Switch GB2 GB1 2 00 07 af ff e6 a0 192 168 1 217 255 255 255 0 N TRON Switch GB2 GB1 3 00 07 af...

Страница 69: ...nt 0 Active Members Detected In Current N Ring 0 reporting Switch No MAC Address IP Address Subnet Mask Name Ports RM 00 07 af 00 b1 40 192 168 1 135 255 255 255 0 N TRON Switch GB2 GB1 The screenshot...

Страница 70: ...g size which can be modified There are 5 types of events that the 7014 will categorize messages in If the log level is set to 1 the 7014 will log all 5 types of events If the log level is set to 5 it...

Страница 71: ...t Log Show Events The Show Events tab under the Event Log category will show a list of events that have occurred in the order in which they occurred There is a time stamp for each event and they are c...

Страница 72: ...ater time Administrators are also given the ability to flash the switch in the field allowing them to update the firmware in the field without losing their current configurations and without having to...

Страница 73: ...ater time Administrators are also given the ability to flash the switch in the field allowing them to update the firmware in the field without losing their current configurations and without having to...

Страница 74: ...152 Support Web Site and E mail If at any point in time you get confused or would like additional support directly from N Tron you may visit N Tron s web site or e mail N Tron directory with the links...

Страница 75: ...t Count Limit Configuration The BPCL link will display all the ports that are installed in the 7014 Series unit and will list the BPCL Percentage for each port BPCL defaults to 3 A modify button is pr...

Страница 76: ...ised 2011 07 21 page 76 of 152 BPCL Broadcast Packet Count Limit Configuration Continued Following the Modify button on the previous example the administrator can modify the BPCL Percentage for each p...

Страница 77: ...user a username a password and the user s permissions user administrator A page should display after the administrator clicks the Add button stating that the user was successfully added NOTE There ar...

Страница 78: ...simply click on the Remove button at the bottom of the page Following the Remove button on the last page the administrator can remove a user by entering in the user s name and clicking the Remove but...

Страница 79: ...switch Here a user or administrator can see a graphical depiction of the 7014 switch Ports that are linked will turn green while ports that are not linked will show up as black The example below shows...

Страница 80: ...needed in order for the switch to remember any changes after a power cycle The Reset Configuration button will reload N Tron s factory default configuration settings Doing so will re configure the 70...

Страница 81: ...p link is clicked on you will see the Overview page that will have some basic definitions and more specific choices at the top of the screen Although this page is not as detailed as the manual is it g...

Страница 82: ...152 Help Administration Selecting the Administration link on the help page the administrator or user can see some information regarding the configuration options in the Administration category on the...

Страница 83: ...1 page 83 of 152 Help Ports Following the Ports link on the help page the administrator or user can see some information regarding the configuration options in the Ports category on the left side of t...

Страница 84: ...84 of 152 Help Statistics Following the Statistics link on the help page the administrator or user can see some information regarding the configuration options in the Statistics category on the left s...

Страница 85: ...07 21 page 85 of 152 Help VLAN Using the VLAN link on the help page the administrator or user can see some information regarding the configuration options in the VLAN category on the left side of the...

Страница 86: ...21 page 86 of 152 Help BPCL Using the BPCL the link on the help page the administrator or user can see some information regarding the configuration options in the BPCL category on the left side of th...

Страница 87: ...21 page 87 of 152 Help IGMP Following the IGMP link on the help page the administrator or user can see some information regarding the configuration options in the IGMP category on the left side of th...

Страница 88: ...page 88 of 152 Help Bridging Using the Bridging link on the help page the administrator or user can see some information regarding the configuration options in the Bridging category on the left side o...

Страница 89: ...07 21 page 89 of 152 Help RSTP Using the RSTP link on the help page the administrator or user can see some information regarding the configuration options in the RSTP category on the left side of the...

Страница 90: ...ge 90 of 152 Help Event Log Using the Event Log link on the help page the administrator or user can see some information regarding the configuration options in the Event Log category on the left side...

Страница 91: ...152 Help Firmware Config Using the Firmware Config link on the help page the administrator or user can see some information regarding the configuration options in the Firmware Config category on the l...

Страница 92: ...2 of 152 Help Logical View Using the Logical View link on the help page the administrator or user can see some information regarding the configuration options in the Logical View category on the left...

Страница 93: ...ge 93 of 152 Help User Mgmt Using the User Mgmt link on the help page the administrator or user can see some information regarding the configuration options in the User Mgmt category on the left side...

Страница 94: ...21 page 94 of 152 Help N View Using the N View link on the help page the administrator or user can see some information regarding the configuration options in the N View category on the left side of t...

Страница 95: ...21 page 95 of 152 Help N Ring Using the N Ring link on the help page the administrator or user can see some information regarding the configuration options in the N Ring category on the left side of t...

Страница 96: ...07 21 page 96 of 152 Help Others Following the Others link on the help page the administrator or user can see some information regarding other links or categories on the left hand side of the web man...

Страница 97: ...d and if they match a specific command the usage of the command will be displayed otherwise if keywords matches the prefix of a command s the name of the command s will be listed If is preceded by ano...

Страница 98: ...up Description Changes the context to the next higher level If already at the topmost context the command is simply ignored Syntax up Parameters None Examples N TRON Admin 1 system show N TRON Admin 2...

Страница 99: ...and with a reference number Syntax history Parameters reverse reverse the order of display to be the most recent entry first maxsize set the maximum no of entries that will be maintained in the list t...

Страница 100: ...history list that has to be repeated Str The most recent command from the history list that begins with keyword str Examples N TRON Admin 1 Referenced command is not in the history list N TRON Admin 2...

Страница 101: ...ON Admin 2 whoaim Now we can edit the command at the command prompt NOTES After entering 1 at the prompt it displays the previously entered command Whoami Command Name whoami Description This command...

Страница 102: ...s IP Address The IP address of the system in dotted decimal notation Subnet The subnet of the above specified IP Address Gateway The gateway address of the system Example N TRON Admin 1 system set ip...

Страница 103: ...c Address of the System Command Name system get sysmac Description To display the mac address of the device Syntax system get sysmac Parameters None Example N TRON Admin 1 system get sysmac System MAC...

Страница 104: ...Location of the system Parameters Location of the system The details of where the system is located Example N TRON Admin 1 system set syslocation San Jose N TRON Admin 2 system set syslocation Hyderab...

Страница 105: ...community public N TRON Admin 1 system set snmpgetcommunity N Tron Systems Notes Please ensure to use for supplying arguments with spaces Set SNMP Set Community name Command Name system set snmpsetcom...

Страница 106: ...it Transceiver Port 14 Gigabit Transceiver Notes Show all configuration parameters related to SNMP manager Command Name system show snmpinfo Description To show all the configuration parameters relate...

Страница 107: ...prompted for a password of 3 to 15 characters in length Example N TRON Admin 1 system add user ntron user Enter User Password NOTES Users with User permissions can not make changes to the switch but c...

Страница 108: ...System User Command Name system remove user Description To remove a user from the users list Syntax system remove user username Parameters username The user s username that is to be removed Example N...

Страница 109: ...TRON Admin 1 tftp set serverparam 10 1 1 151 usr local tftp flash NOTES Please ensure that TFTP ServerIP is a valid IP Address by pinging it Show TFTP configuration parameters Command Name tftp show...

Страница 110: ...dress of the FTP server to be used for establishing the FTP connection for transfer of files data Syntax ftp set serverip Server IP address Parameters Server IP address The IP address of the FTP serve...

Страница 111: ...retrieves a remote file from the FTP server and put stores a local file at the FTP server Syntax ftp get config ftp put config Parameters Action command The desired File transfer action either get or...

Страница 112: ...Adminstatus is used to enable or disable the port operations even though there are active connections Syntax port get adminstatus port no Parameters port no Port number 1 14 Examples N TRON Admin 1 po...

Страница 113: ...no is in the valid range 1 14 Get total number of good frames received Command Name port get totalgoodframes Description Gets the total number of good frames received on the switch Syntax port get to...

Страница 114: ...the port duplex mode HALF_DUPLEX FULL_DUPLEX for a given port number Syntax port set duplexmode port no full half Parameters port no Port number 1 12 full half Duplex mode of the port Duplex mode mus...

Страница 115: ...Name port set autonego Description Sets the auto negotiation mode of a given port to either enable or disable If the port auto negotiation mode is enabled the switch can automatically adjusts it speed...

Страница 116: ...n Set a port s VLAN ID Syntax port set pvid port no pvid number Parameters port no port number 1 14 pvid number The VLAN ID number of the VLAN that this port will be a member of Examples N TRON Admin...

Страница 117: ...how intruder Parameters None Examples N TRON Admin 1 port show intruder NOTES Intruder log must be enabled before this will log anything Show Link Utilization Command Name port show linkutilization De...

Страница 118: ...ty level on a given port Syntax port get prioritylevel port no Parameters port no port number 1 14 Examples N TRON Admin 1 port get prioritylevel 6 Priority Level of Port 6 is 1 NOTES Check whether po...

Страница 119: ...counters for RX bytes and TX bytes and so on Syntax port clear counters port no Parameters port no port number 1 14 Examples N TRON Admin 1 port clear counters 6 Counters of Port 6 are cleared NOTES T...

Страница 120: ...name trunk1 NOTES A maximum of 4 ports can be in a trunk All trunk ports must be at the same speed and duplex mode If a port is not linked there could be difficulty matching similar speed and duplex m...

Страница 121: ...of 152 Show Trunk Information Command Name trunk show Description To show all the trunks information Syntax trunk show Parameters None Examples N TRON Admin 1 trunk show TRUNK NAME TRUNK PORTS TRUNK S...

Страница 122: ...to receive the copies of Ethernet frames that are being transmitted out and also being received in from any other port that is being monitored Enable or Disable Port Mirroring Command Name mirror set...

Страница 123: ...d using a hyphen 10 15 The port numbers cannot exceed the maximum number of ports on the board tagged port mask Tagged port mask values can be specified in the same way as that of an untagged port mas...

Страница 124: ...eters vlan id unique vlan id 2 4094 mgmt port Management Port yes or no 1 or 0 untagged port mask List of ports that are to be included under this VLAN Commas can be used to separate individual ports...

Страница 125: ...o defaults Command Name vlan set default Description Removes all the configured vlans and add all the ports under the Default vlan Syntax vlan set default Parameters None Examples N TRON Admin 1 vlan...

Страница 126: ...of 152 Get VLAN info Command Name vlan get info Description Displays the current state of the configured vlans Syntax vlan get info vlanid Parameters vlanid Enter a specific Vlan ID Examples N TRON A...

Страница 127: ...log get logsize Parameters None Examples N TRON Admin 1 eventlog get logsize Present Log Size 100 NOTES Set Eventlog level Command Name eventlog set loglevel Description To set the log level to a spec...

Страница 128: ...07 21 page 128 of 152 Show Eventlog events Command Name eventlog show events Description To display the logged events Syntax eventlog show events Parameters None Examples N TRON Admin 1 eventlog show...

Страница 129: ...Multicast MAC Address Command Name bridge delete multicastmac Description Removes an existing multicast mac address Syntax bridge delete multicastmac mac address Parameters mac address Multicast grou...

Страница 130: ...0 seconds Maximum aging time is 1000000 seconds Examples N TRON Admin 1 bridge set agingtime 20 NOTES Display Current Aging Time Command Name bridge show agingtime Description Displays the current agi...

Страница 131: ...131 of 152 Display Mac count Command Name bridge show maccount Description Displays the total count of the static mac addresses Syntax bridge show maccount Parameters None Examples N TRON Admin 1 bri...

Страница 132: ...isabled Querier Enabled Query Mode auto Router Mode auto Router Ports Manual NOTES The status can be viewed through the igmp show config command Show IGMP config Command Name igmp show config Descript...

Страница 133: ...a router port based on a port range Syntax igmp set rtrport port range enable disable Parameters port range enter a range of port numbers enable disable enable or disable the router port Examples N T...

Страница 134: ...rfilter Description The igmp set rfilter command is used to enable or disable rfilter based on a port range Syntax Usage igmp set rfilter enable disable port list all Parameters enable disable Enable...

Страница 135: ...ers aging time aging time to be set for N Ring Minimum N Ring agingtime can be 5 seconds Default N Ring aging time is 20 seconds Maximum aging time is 1000000 seconds Examples N TRON Admin 1 n ring se...

Страница 136: ...Health Packets constitute a fault N Ring get mode Command Name n ring get mode Description To display the current N Ring Mode Syntax n ring get mode Parameters None Example N TRON Admin 1 n ring get...

Страница 137: ...embers Shows if Automember or active member If active manager or member shows N Ring ports Syntax n ring show status Parameters None Examples On an N Ring Manager N TRON Admin 1 n ring show status Swi...

Страница 138: ...Ring set keepalive Command Name n ring set keepalive Description Set timeout after which an N Ring member will drop back to RSTP mode on the N Ring ports after loosing communication with the N Ring ma...

Страница 139: ...ation Upload Command Name config send Description The configuration on the flash is grouped into a file and sent to the tftp server Syntax config send Server IpAddress File Name Parameters Server IpAd...

Страница 140: ...d port Port for which the adminedge value is to be viewed Examples N TRON Admin 1 rstp get adminedge 1 1 N TRON Admin 2 rstp get adminedge 2 2 NOTES Set RSTP Auto Edge Command Name rstp set autoedge D...

Страница 141: ...Delay in STP is the time a switch waits after connecting to a root bridge before he changes the port state to forwarding from the listening and learning states RSTP only uses this as a backup feature...

Страница 142: ...hellotime 1 N TRON Admin 2 rstp get bridge hellotime 2 NOTES Please supply valid Vlan Index being greater than zero Set RSTP Bridge Max Age Command Name rstp set bridgemaxage Description To set the Ma...

Страница 143: ...N Admin 2 rstp get bridgepriority 2 NOTES Set RSTP Port Path Cost Command Name rstp set portpathcost Description To set the port path cost for a given port in the given vlan id STP and RSTP use the pa...

Страница 144: ...Examples N TRON Admin 1 rstp set portpriority 1 4 100 N TRON Admin 2 rstp set portpriority 2 6 50 NOTES Please supply a valid Vlan Index being greater than zero and Port Number If the port priority is...

Страница 145: ...acket percentage for all ports Syntax broadcast show percentage Parameters None Examples N TRON Admin 1 broadcast show percentage Broadcast Percentage Value for Ports Port 1 100 Port 14 100 Port 2 100...

Страница 146: ...ort P6 Strips VID off packet Example 2 Basic understanding of tagged VLANs Admit Tagged Only VLAN Configuration View Ports Configuration View VLAN Status Enable VLAN ID VLAN Name Untagged Port s Tagge...

Страница 147: ...understanding of Hybrid VLANs VLAN Configuration View Ports Configuration View VLAN Status Enable VLAN ID VLAN Name Untagged Port s Tagged Port s Mgmt Port Admit Mirror Port 1 Default VLAN P3 P12 YES...

Страница 148: ...AC on port P3 Packet Discarded Port P1 VID 4 MAC on port P2 Port P2 Strips VID off packet Port P1 VID 4 Unknown MAC Port P2 Strips VID off packet Floods VLAN 4 Port P2 Untagged MAC on port P1 Port P1...

Страница 149: ...ged 01 00 00 00 00 01 Port P1 P3 P12 Goes to Ports P1 P12 but won t go back out the port it came in on Port P2 Untagged 01 00 00 00 00 02 Port P1 P6 P8 Goes to ports P1 P6 P8 Port P3 Untagged 01 00 00...

Страница 150: ...C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration bulkhead mounting Shock 200g 10ms Vibration Seismic 50g 5 2...

Страница 151: ...80km TX Power Min 19dBm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength Min Max 1310nm 1310nm 1310nm 1550nm Multimode Fiber Optic Cable Singlemode Fiber Optic Cable Regulatory A...