CLI Commands, Continued…
Show or Clear the Last System Error
Command Name
Syserr
Description
Show or clear the last system error
If clear is not supplied, then the last system error is displayed.
Syntax
syserr [clear]
Parameters
Clear
Clear the last system error.
Example
N-TRON/Admin> syserr
Last System Error: None.
N-TRON/Admin> syserr clear
Last System Error: Cleared.
Notes
Show System Information
Command Name
Sysinfo
Description
Show system information
Syntax
Sysinfo
Parameters
None
Example
N-TRON/Admin> sysinfo
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+
+ N-TRON 700/7000/7500 Series
+
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+
+ Model: 7012FX2
+ Boot Loader: BL 2.0.5.1 (0x02000501)
+ OS Version: 3.4.6
+ Build Date: Sep 14 2010 at 10:18:23
+ Copyright: Copyright (c) 2008-2010 N-TRON Corp. All rights reserved.
+
+ Processor: 66 MHz (66000000)
+ SDRAM Size: 16 MB
+ Flash Size: 8 MB
+ File System: 6422528 Bytes, 2599936 Free, 3822592 Used, 0 Bad
+ MAC Address: 00:07:af:fa:bc:80
+ IP Address: 192.168.1.201
+ Subnet Mask: 255.255.255.0
+ Gateway: 192.168.1.1
+ Cfg Device: SDS128M
+
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
N-TRON/Admin>
Notes
Содержание 7012FX2 Series
Страница 34: ...Revised 2012 05 01 Page 34 of 170 Administration SNMP Continued...
Страница 38: ...Revised 2012 05 01 Page 38 of 170 DHCP Server Setup Profiles Continued...
Страница 41: ...Revised 2012 05 01 Page 41 of 170 DHCP Server Setup IP Maps Continued...
Страница 47: ...Revised 2012 05 01 Page 47 of 170 DHCP Relay Local IP Setup Continued...
Страница 53: ...Revised 2012 05 01 Page 53 of 170 Ports Configuration Continued...
Страница 87: ...Revised 2012 05 01 Page 87 of 170 IGMP RFilter Continued Modifying rfilter port settings...
Страница 95: ...Revised 2012 05 01 Page 95 of 170 N Ring Advanced Configuration Continued...
Страница 121: ...Revised 2012 05 01 Page 121 of 170 If a Configuration Device is present that is presented...