background image

(Revised 2012-05-01)                                                                                                                                                                                          

Page 1 of 170

 

 

 

 
 
 
 
 

 
 

 
 

7012FX2 

Managed Industrial  

Ethernet Switch 

 

 

 

      

User Manual & 

Installation 

Guide 

 

 
 
 
 
 
 
 
 

 
 

Содержание 7012FX2 Series

Страница 1: ...Revised 2012 05 01 Page 1 of 170 7012FX2 Managed Industrial Ethernet Switch User Manual Installation Guide...

Страница 2: ...load 24 Rate Limiting 24 TROUBLESHOOTING 25 Web Software Configuration 26 Web Management 26 Web Management Home 27 Administration System 29 Administration SNMP 33 Administration Fault 35 DHCP Server S...

Страница 3: ...Add or Delete ARL Entries 141 Configuration Device Operations 142 Show or Set CIP Configuration 143 Save or Reset the Configuration Settings 144 Show or Set IGMP Configuration 144 Show or Set Mirror C...

Страница 4: ...Revised 2012 05 01 Page 4 of 170 KEY SPECIFICATIONS 7012FX2 163 KEY SPECIFICATIONS 7012FX2 HV 165 Appendix A XML Settings File Example 167 N TRON Limited Warranty 170...

Страница 5: ...al Ethernet Switch Installation Guide The N TRON 7012FX2 Industrial Ethernet Switch offers outstanding performance and ease of use It is ideally suited for connecting Ethernet enabled industrial and o...

Страница 6: ...SFP Mini GBIC Fiber Transceivers NTSFP SX LC Style Connector up to 550m NTSFP LX 10 LC Style Connector up to 10km NTSFP LX 40 LC Style Connector up to 40km NTSFP LX 80 LC Style Connector up to 80km M...

Страница 7: ...s area is known to be non hazardous Connection or disconnection in an explosive atmosphere could result in an explosion NTCD 128 Configuration Device Ideal for saving or restoring switch configuration...

Страница 8: ...rranties of merchantability or fitness for a particular purpose In no event shall N Tron Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited...

Страница 9: ...com E MAIL N TRON_Support n tron com ENVIRONMENTAL SAFETY WARNING The unit may become very hot to the touch in high temperature environments so extreme caution should be exercised in handling when en...

Страница 10: ...USB connectors are for temporary connection only Do not use connect or disconnect unless area is known to be non hazardous Connection or disconnection in an explosive atmosphere could result in an ex...

Страница 11: ...vised 2012 05 01 Page 11 of 170 UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cl...

Страница 12: ...5 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place To remove the unit from the 35mm industrial DIN rail pull forward on the unit until it disengages fro...

Страница 13: ...Sensing 10 100 Base TX Connections LED lights when Power is supplied to the unit NOTE The RJ45 data port has two LEDs located on each connector The left LED indicates LINK status and the right LED in...

Страница 14: ...Revised 2012 05 01 Page 14 of 170 OFF Power is OFF LNK GREEN 10 100Mb Link between ports OFF No Link between ports ACT GREEN Data is active between ports OFF Data is inactive between ports...

Страница 15: ...aw current from both sources simultaneously Use 16 28 gauge wire when connecting to the power supply The Fault pins on the power connector can be used for an alarm contact The current carrying capacit...

Страница 16: ...her device end node Switch or Repeater use a standard Category 5E straight through or crossover cable with a minimum length of one meter and a maximum length of 100 meters N Tron recommends the use of...

Страница 17: ...ate users can run a drain wire shown in green lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care shoul...

Страница 18: ...Revised 2012 05 01 Page 18 of 170 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications...

Страница 19: ...he bottom of the 7012FX2 USB Cable Connect the USB port of your PC and the Switch using a standard USB cable You will require a cable with a Type A connector for the PC end and a Type B connector for...

Страница 20: ...tion for a shared medium in this mode Auto Negotiation In Auto Negotiation mode the port hardware detects the mode of operation of the station that is connected to this port and sets its mode to match...

Страница 21: ...hen it is used in a network A port is automatically removed from the Default VLAN when it is reconfigured to belong to another Virtual LAN because that is the most common operation But if desired the...

Страница 22: ...igure bridge ports to use the older STP when desired SNMP Traps The 7012FX2 Series switch supports up to 5 SNMP Trap Stations to which SNMP Traps will be sent The switch supports five standard traps L...

Страница 23: ...en a problem is detected on the Primary Coupler link the Primary Coupler link will block network traffic and the Standby Coupler link will forward network traffic While the N Link Master and Slave are...

Страница 24: ...are those that the switch detects on any port while in Learning mode A manually entered MAC address must designate the ports that the address is authorized on A non authorized MAC address will be disc...

Страница 25: ...protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruct...

Страница 26: ...05 01 Page 26 of 170 Web Software Configuration Web Management Enter the switch s IP address in any web browser and login to the web management feature of the 7012FX2 Series Default User Name admin P...

Страница 27: ...igurable settings that the 7012FX2 Series switch will support This section of the manual will go through each and every choice listed on the left hand side of the screen and explain how to configure t...

Страница 28: ...here is a menu which is shown fully opened below The pages opened by each of the individual selections are described in the rest of this section The use of each of these pages is also described in thi...

Страница 29: ...ct which allows alphanumeric and special characters _ only Contact The person to contact for system issues which should be someone within your organization Location The physical location of the switch...

Страница 30: ...CP clients to specify their unique identifier The identifier may be the MAC address switch name or entered as a text string or hex characters Fallback IP Address Contains the configured Fallback IP Ad...

Страница 31: ...Subnet Mask Gateway Name Contact information and the Location of the switch through the web management features depending on the IP Configuration It is recommended to change the TCP IP information th...

Страница 32: ...hanged from the default IP address then the switch will use the Fallback addresses if the IP configuration isn t received from a DHCP server in 2 minutes after initial boot If Fallback address is used...

Страница 33: ...Write and Trap Community Names are also shown here By selecting the Modify button you will be able to change any of the fields listed This allows the user to set an IP address for a Trap station or c...

Страница 34: ...Revised 2012 05 01 Page 34 of 170 Administration SNMP Continued...

Страница 35: ...s Show Web Show LED and Contact Power signal faults consist of V1 and V2 N Ring Manager signal faults consist of Broken Partial Break Low Partial Break High and Multiple Managers N Link Faults are rep...

Страница 36: ...fields for the Fault configuration The fault relay contacts can be configured to open on fault or to close on fault with the latter being the default Once these fields are filled in to meet the needs...

Страница 37: ...processing a broadcast message Server ID Descriptive name of the DHCP server Profile Name Descriptive name of the network profile Address Pool Range of IP addresses which the profile can use Subnet A...

Страница 38: ...Revised 2012 05 01 Page 38 of 170 DHCP Server Setup Profiles Continued...

Страница 39: ...b provides the way to create IP mappings with an existing network profile There are three types of mappings that can be created Dynamic Range Static Range and Single IP Before a non default Network pr...

Страница 40: ...nt data entry formats available according to whether the relay agent type is for an N TRON or for a generic switch To create a range of static IP addresses on an N Tron relay agent switch Network Prof...

Страница 41: ...Revised 2012 05 01 Page 41 of 170 DHCP Server Setup IP Maps Continued...

Страница 42: ...ric Port Count The number of ports on the particular relay agent switch Add Checkbox used to add an IP map for the corresponding port Port No The actual port number Remote ID The identifier that corre...

Страница 43: ...ndividual client The following information is required Network Profile An existing network profile to which the IP map applies IP The static IP address to offer to a client Unique ID The unique identi...

Страница 44: ...fier The client associated with the binding entry Client Hardware Address MAC The client s MAC address Client IP Address The actual IP address assigned to the binding entry Status Indicates the curren...

Страница 45: ...Setup tab under the DHCP Relay Local IP category shows the current state of the relay agent By selecting the Modify button you can configure general settings of the relay agent as well as configure se...

Страница 46: ...her the port will perform relay agent functionality The choices are Disabled The port will function without relay agent processing Enabled The port will relay DHCP client originated broadcast packets...

Страница 47: ...Revised 2012 05 01 Page 47 of 170 DHCP Relay Local IP Setup Continued...

Страница 48: ...between Disabled and Enabled on LLDP Port settings Default 2 Seconds Notification Interval Specifies the interval between successive Notifications generated by the switch If a port sends out a notific...

Страница 49: ...LLDP Transmission on the switch Receive Enables or Disables Receiving of LLDP Frames from neighbor switches Allow Management Data Allow the Transmission of Management type information For example IP A...

Страница 50: ...ch the neighbor information was received Neighbor MAC MAC address of neighbor switch Corresponds to the LLDP Chassis ID TLV Neighbor IP IP address of neighbor switch Corresponds to the LLDP Management...

Страница 51: ...tal number of LLDP frames received by the local switch Discarded Frames The total number of frames discarded due to incorrect TLV s in frame Error Frames Total count of all LLDP frames received with o...

Страница 52: ...ort This can be Yes No or Auto Auto is the default Flow Control State This configurable field displays the existing flow control status of each port When enabled the individual port supports half dupl...

Страница 53: ...Revised 2012 05 01 Page 53 of 170 Ports Configuration Continued...

Страница 54: ...User can click on the Port Number to configure each port individually This will allow the user to change the port s settings for the following fields which are explained above Admin Status Speed and...

Страница 55: ...left hand navigation under Ports The Learning tab allows the administrator to control the learning or locking modes for the ports Locked is the secure mode Learning builds an internal list of authoriz...

Страница 56: ...vised 2012 05 01 Page 56 of 170 In Locked mode Secured Ports shows the ports that are presently secured Note when N Ring and or N Link are used the N Ring N Link ports will not have MAC Security enabl...

Страница 57: ...e the ports selected for MAC Security When transitioning from Learning to Locked the Address Resolution Logic ARL table represents the authorized MAC addresses with the addition of any manually entere...

Страница 58: ...ted authorized ports Selecting Delete removes the associated entry Selecting Add displays the MAC Authorization Entry page showing default values for the administrator to modify see below When an entr...

Страница 59: ...currence of the intruder is listed The log is ordered by most recent first based on the system time The maximum number of entries is 100 If more than 100 intruders are detected the oldest entries are...

Страница 60: ...other port that is being monitored The Mirroring tab under the Ports category displays the status including the list of Source Ports and the Destination Port that the Sources are being mirrored to Mi...

Страница 61: ...2 05 01 Page 61 of 170 Ports Mirroring Continued Following the Modify button you can enable the status of port mirroring and select source ports and the destination port that the source ports will be...

Страница 62: ...ton you can select a trunk group Note RSTP must be disabled in order to use the Trunking feature Two ports of the same speed can constitute a valid trunk Only 1 Trunk per switch can be created All tru...

Страница 63: ...included when evaluating traffic priority Include 802 1p This field displays the status of whether or not to include the IEEE 802 1p COS Class of Service in the TQ decision When enabled the IEEE 802...

Страница 64: ...utton the administrator can independently configure the ports for different QOS functionality Once these fields are filled in to meet the needs of the administrator s network the changes may be update...

Страница 65: ...of MIB parameters Each port has a separate counter for each parameter This gives users the ability to see what kind of packets are going over which ports At the bottom of the page for each port there...

Страница 66: ...s all the ports on the switch and will display a bar graph showing the percentage of bandwidth being used These figures and bars are for a general feeling of what the bandwidth usage is N Tron recomme...

Страница 67: ...not to replace the incoming VID tag with the port s designated VID Perform Ingress Filtering Specifies whether or not to filter out ingress frames when a VID violation is detected Discard Non Tagged...

Страница 68: ...is added to another group Ports are added to group1 if a deletion leaves a port with no group If it is desired to have a port on group1 and also on other group s configure group1 last to achieve that...

Страница 69: ...cters _ only Allow Management Specifies whether or not all ports in this VLAN are management ports Change PVID of Member Ports Specifies whether or not the PVID of the member ports is set to this VLAN...

Страница 70: ...s page allows users to modify this variable to meet their needs After selecting the Modify button the user will be presented with a page that allows the number to be entered and updated The default ag...

Страница 71: ...e associated with each respective port number This can be used to statically assign a MAC address access to a single port on the switch Following the Add button on the page above the administrator mus...

Страница 72: ...ill be displayed in a list on the main page under Unicast MACs tab Following the Remove button on the example above an administrator can select a static MAC address from the list using a pull down men...

Страница 73: ...er a valid Multicast Group Address and associate it with a port number or list on the switch Once the administrator clicks on the Add button the changes will take effect instantly Note If there are mu...

Страница 74: ...witch Using the pull down menu the administrator should select the desired address to be removed Then click on the Remove button at the bottom of the page Note If there are multiple ports on different...

Страница 75: ...sing the Modify button and also displays the existing Enabled or Disabled status of this feature The default is disabled When disabled the switch generates no ethernet traffic for this purpose but can...

Страница 76: ...sed to detect their IP Address Invoking the Assign IP button on the example above the administrator will be presented with a form in which to enter a manually assigned IP as below When an IP has been...

Страница 77: ...ry will display the RSTP information for the first VLAN Using the pull down menu at the top of the page an administrator can choose which VLAN to configure RSTP on Once the VLAN is selected the admini...

Страница 78: ...The administrator or user can see the current RSTP status of the ports on that VLAN by clicking on the here link to view RSTP Port Configuration at VLAN Note It is recommended that RSTP rings consist...

Страница 79: ...t RSTP status of the ports on that VLAN This will show information such as the Path Cost and the Port State If the switch sees a redundant path it will put the port with the highest Path Cost into Blo...

Страница 80: ...05 01 Page 80 of 170 RSTP Configuration Continued If the administrator selects one of the ports on the previous screen he or she can change the Port s Path Cost Priority and the status of Admin Edge...

Страница 81: ...configuration settings By default IGMP is enabled Following the Modify button the administrator will see a list of configurable fields for the IGMP configuration Once these fields are filled in to me...

Страница 82: ...82 of 170 IGMP Configuration Continued The IGMP Status pull down allows the user to enable or disable IGMP completely The Query Mode pull down allows the user to set query mode for Automatic the defau...

Страница 83: ...inued The Router Mode pull down allows the user to choose router mode Auto allows for dynamically detected and manually set router ports Manual allows only for manually set router ports None allows no...

Страница 84: ...sed IGMP Groups will be removed and traffic with those multicast addresses will be treated as normal multicast If unchecked then unused IGMP Groups are not removed and traffic with those multicast add...

Страница 85: ...ups tab under the IGMP category will display a list of IGMP groups based on the Group IP and the port number that it is associated with The Show Routers tab under the IGMP category will display a list...

Страница 86: ...ions The factory default is that the Router Multicast Data Filter is enabled for all ports so any router ports do NOT get DATA frames with KNOWN multicast destination addresses unless a join to a spec...

Страница 87: ...Revised 2012 05 01 Page 87 of 170 IGMP RFilter Continued Modifying rfilter port settings...

Страница 88: ...nd the interval between packets Following the Modify button on the above example the administrator can modify the variable to change the frequency with which N View reports information Increasing the...

Страница 89: ...01 Page 89 of 170 N View Ports The Ports tab under the N View category will display a list of all the configured ports on the 7012FX2 unit along with the ports transmitting multicast packets and MIB s...

Страница 90: ...90 of 170 N View Ports Continued Following the Modify button on the above example the administrator can modify these two variables to enable or disable multicast out of the port and if MIB stats are...

Страница 91: ...or example Switch is currently using N Ring Aging Time 20 Seconds Once these fields are filled in to meet the needs of the administrator s network the changes may be saved by clicking the Update butto...

Страница 92: ...05 01 Page 92 of 170 N Ring Configuration Continued The N Ring Mode is one of three as below If N Ring Mode is Manager then a pull down allows selection of available ports TX1 TX2 FX1 FX2 or GB1 GB2 a...

Страница 93: ...ges It is up to the administrator to ensure that VLANs are configured correctly on the N Ring manager and all N Ring members 2 When the N Ring manager and all N Ring Members are in defaults changing t...

Страница 94: ...al sign on information from ring members The default is 1000 Sign On Match Packets The number of times the switch count must match before starting the sign on process The default is 3 Sign On Interval...

Страница 95: ...Revised 2012 05 01 Page 95 of 170 N Ring Advanced Configuration Continued...

Страница 96: ...he N Ring category will display the N Ring status Below is an example of N Ring Status from a switch in defaults N Ring Auto Member that is not an N Ring Manager and has not become an Active N Ring Me...

Страница 97: ...Revised 2012 05 01 Page 97 of 170 N Ring Status Continued Below is an example of N Ring Status from an N Ring Manager with a healthy N Ring...

Страница 98: ...tus from an N Ring Manager with a faulted N Ring The red fields on the N Ring Map show problems Ports that are red indicate that the port is not linked MAC addresses that are red indicate that there i...

Страница 99: ...nshot below shows N Ring Manager Status when a Higher N Ring Port TX2 TX8 or GB2 is not receiving self health frames all the way around the N Ring though the other low TX1 TX7 or GB1 N Ring port is Th...

Страница 100: ...ber N Link Slave N Ring Member N Link Master N Ring Member Partner Link N Ring Segment Control Link N Ring Auto Member N Rng Manager N Link Coupler N Ring Member N Link Couper N Ring Member N Ring Aut...

Страница 101: ...converters or other switches is not supported There must be at least one other switch besides the Master and Slave that supports N Link on the N Ring N Link will only support a single point of failur...

Страница 102: ...the Modify button on the above example the administrator will see a list of configurable fields for the N Link configuration as below The port configured as the Default Coupler Port will be used as t...

Страница 103: ...as below If N Link mode is Master then the administrator must configure the Control Port default TX3 and the Primary Coupler Port default TX4 Once these fields are filled in to meet the needs of the...

Страница 104: ...itches is not supported This port will be detected automatically Coupler Port The port being used to establish a redundant path for ethernet data transmission Coupler Port State Blocking Forwarding St...

Страница 105: ...Revised 2012 05 01 Page 105 of 170 N Link Status Continued Below is an example of N Link Status from an N Link Coupler switch Below is an example of N Link Status from an N Link Master switch...

Страница 106: ...01 Page 106 of 170 N Link Status Continued Below is an example of N Link Status from an N Link Slave switch Below is an example of N Link Status from an N Link Master and Slave where the Primary Coupl...

Страница 107: ...N Link Status Continued Below is an example of N Link Status from an N Link Master and Slave where the Standby Coupler link is broken Below is an example of N Link Status from an N Link Master and Sla...

Страница 108: ...Revised 2012 05 01 Page 108 of 170 N Link Status Continued Below is an example of N Link Status from an N Link Master and Slave where the Partner link is broken...

Страница 109: ...ed Packet Interval for Class 1 multicast connections in milliseconds Requests for less than this value will be rejected Default 1 second Unicast RPI The minimum Requested Packet Interval for Class 3 u...

Страница 110: ...The ODVA Device Type is Communications Adapter 0x0C hex Major Revision The Major Revision of the CIP implementation Minor Revision The Minor Revision of the CIP implementation Serial Number hex CIP Se...

Страница 111: ...current configurations and without having to send the unit back to N Tron for updates in the future It is important not to cycle power on the switch or interrupt the data connection between the TFTP s...

Страница 112: ...es the administrator may choose to upload or down load only certain configuration settings or to retain his current network settings These choices are available as below For more detail on the choices...

Страница 113: ...170 Support Web Site and E mail If at any point in time you get confused or would like additional support directly from N Tron you may visit N Tron s web site or e mail N Tron directly with the links...

Страница 114: ...adcast or Multicast Rate Limiting These are ingress filters The Broadcast Rate Limit View displays all the ports in the 7012FX2 Series unit and lists the percentage pass rate for each port The factory...

Страница 115: ...15 of 170 Following the Modify button on the above example the administrator can modify the percentage for each and every port independently A selection is provided for all ports to be set at once whe...

Страница 116: ...each port A Modify button is provided to change these fields The factory default for multicast rate limiting is 100 pass rate on all ports Following the Modify button on the above example the administ...

Страница 117: ...anagement features of the switch and their access permissions Following the Add button on the above example the administrator can add another user and assign the user a username a password and the use...

Страница 118: ...the user s name and clicking the Remove button A page should follow indicating that the user was successfully removed from the list Note There are a maximum number of 5 users per switch User permissio...

Страница 119: ...al depiction of the 7012FX2 series switch Ports that are linked will appear in green while ports that are not linked will appear in black The example below shows a 7012FX2 with ports 1 3 4 5 and 7 lin...

Страница 120: ...ot The Reset button will discard all unsaved changes reset the switch and load the most recently saved configuration settings Note Upon restart if a configured configuration device is connected the sw...

Страница 121: ...Revised 2012 05 01 Page 121 of 170 If a Configuration Device is present that is presented...

Страница 122: ...lp link is clicked on you will see the Overview page that will have some basic definitions and more specific choices at the top of the screen Although this page is not as detailed as the manual it giv...

Страница 123: ...170 Help Administration Following the Administration link on the help page the administrator or user can see some information regarding the configuration options in the Administration category on the...

Страница 124: ...Page 124 of 170 Help DHCP Following the DHCP link on the help page the administrator or user can see some information regarding the configuration options under the DHCP categories on the left side of...

Страница 125: ...01 Page 125 of 170 Help LLDP Following the LLDP link on the help page the administrator or user can see some information regarding the configuration options in the LLDP category on the left side of th...

Страница 126: ...1 Page 126 of 170 Help Ports Following the Ports link on the help page the administrator or user can see some information regarding the configuration options in the Ports category on the left side of...

Страница 127: ...27 of 170 Help Statistics Following the Statistics link on the help page the administrator or user can see some information regarding the configuration options in the Statistics category on the left s...

Страница 128: ...01 Page 128 of 170 Help VLAN Following the VLAN link on the help page the administrator or user can see some information regarding the configuration options in the VLAN category on the left side of th...

Страница 129: ...e 129 of 170 Help Bridging Following the Bridging link on the help page the administrator or user can see some information regarding the configuration options in the Bridging category on the left side...

Страница 130: ...01 Page 130 of 170 Help RSTP Following the RSTP link on the help page the administrator or user can see some information regarding the configuration options in the RSTP category on the left side of th...

Страница 131: ...01 Page 131 of 170 Help IGMP Following the IGMP link on the help page the administrator or user can see some information regarding the configuration options in the IGMP category on the left side of th...

Страница 132: ...Page 132 of 170 Help N View Following the N View link on the help page the administrator or user can see some information regarding the configuration options in the N View category on the left side of...

Страница 133: ...Page 133 of 170 Help N Ring Following the N Ring link on the help page the administrator or user can see some information regarding the configuration options in the N Ring category on the left side of...

Страница 134: ...Page 134 of 170 Help N Link Following the N Link link on the help page the administrator or user can see some information regarding the configuration options in the N Link category on the left side of...

Страница 135: ...5 01 Page 135 of 170 Help CIP Following the CIP link on the help page the administrator or user can see some information regarding the configuration options in the CIP category on the left side of the...

Страница 136: ...70 Help Firmware Config Following the Firmware Config link on the help page the administrator or user can see some information regarding the configuration options in the Firmware Config category on th...

Страница 137: ...f 170 Help Rate Limiting Following the Rate Limiting link on the help page the administrator or user can see some information regarding the configuration options in the Rate Limiting category on the l...

Страница 138: ...70 Help User Management Following the User Management link on the help page the administrator or user can see some information regarding the configuration options in the User Management category on th...

Страница 139: ...05 01 Page 139 of 170 Help Other Following the Other link on the help page the administrator or user can see some information regarding other links or categories on the left hand side of the web mana...

Страница 140: ...escription of this command will be displayed Syntax cmd Parameters cmd The command for which to get help Examples N TRON Admin The above command displays all the available commands N TRON Admin abcd U...

Страница 141: ...4095 Example N TRON Admin arl show No Val Age Pri Mod Usr Sta VLAN MAC I Port s 1 1 0 0 1 3333 01 07 af fa bc 80 None 2 1 0 0 1 1 01 00 5e 7f ff fa TX7 3 1 0 0 1 3333 01 07 af 00 df 48 None 4 1 0 0 1...

Страница 142: ...he configuration device Erase Erase the switch configuration on the configuration device Example N TRON Factory cfgdev info Port A 0xd080 Board ID 0x0005 5 Configuration device information Name SDS128...

Страница 143: ...Interval 10 ms Cache Interval 2000 ms Identity Information Product Name N TRON 7012FX2 Vendor 1006 N TRON Device Type 0x0C Communications Adapter Major Revision 1 Minor Revision 2 Serial Number 0xAFFB...

Страница 144: ...and Name igmp Description Show or set IGMP configuration If no parameters are specified this command will show the IGMP configuration same as show parameter Syntax igmp show status state Parameters sh...

Страница 145: ...frames tx portlist Set the source ports to mirror frames that are transmitted rx portlist Set the source ports to mirror frames that are received Examples N TRON Admin mirror show Mirror Status Disab...

Страница 146: ...ng show N Ring Mode Auto Member Aging Time 20 N TRON Admin nring ports ID Port Set 1 TX1 TX2 2 TX7 TX8 3 GB1 GB2 N TRON Admin nring mode m ports 2 Do you Want to Save Changes and Restart the System No...

Страница 147: ...unt Number of echo requests to send w timeout Timeout in milliseconds to wait for each reply Example N TRON Admin ping 192 168 1 119 N TRON Admin ping n 6 192 168 1 119 N TRON Admin ping t 192 168 1 1...

Страница 148: ...Set the 802 1p Priority for the port to e nabled or d isabled pvid Set the VLAN ID for the port The range is 1 4094 ual percent Set the usage alarm low percentage The range is 0 100 uah percent Set t...

Страница 149: ...w Show configuration ro name Set the Authorized Community Name for SNMP Get requests rw name Set the Authorized Community Name for SNMP Set requests trap name Set the Authorized Community Name for SNM...

Страница 150: ...Notes Show System Information Command Name Sysinfo Description Show system information Syntax Sysinfo Parameters None Example N TRON Admin sysinfo N TRON 700 7000 7500 Series Model 7012FX2 Boot Loade...

Страница 151: ...et mask for static config mode and IP fallback g static_gateway Static gateway address for static config mode and IP fallback Example N TRON Admin sysip IP Configuration Mode Static Static IP Address...

Страница 152: ...system name Private Switch browser disabled IP Configuration Static Client ID hex 0007affabc80 IP Address 192 168 1 214 Subnet Mask 255 255 255 252 Gateway 192 168 1 1 MAC Address 00 07 af fa bc 80 S...

Страница 153: ...tton allows one to add a new VLAN When creating a new VLAN a numeric ID is required Name is entered Note that N Ring VLAN is a reserved name with a special meaning Choices such as Allow Management and...

Страница 154: ...Revised 2012 05 01 Page 154 of 170 The result of add is a New VLAN In this case it does not overlap the Default VLAN ports...

Страница 155: ...st address to the lowest VLAN ID that is associated with one of the ports assigned to the static multicast address If the lowest VLAN ID contains all the ports assigned to the static multicast address...

Страница 156: ...01 Page 156 of 170 And the New VLAN may be deleted when it is no longer required And the New VLAN is removed Note that the new configuration of the switch must be saved if the configuration must survi...

Страница 157: ...s When used properly it will effectively isolate two or more groups from each other in a logical manner This means that Broadcast Multicast and Unicast frames in one VLAN will not interfere with anoth...

Страница 158: ...ort s Notes TX1 Untagged MAC on port TX2 Packet Discarded TX1 VID 2 MAC on port TX2 TX2 Unicast Traffic TX1 VID 4 MAC on port TX2 Packet Discarded TX1 VID 2 MAC on port TX5 TX2 Floods VLAN 2 TX3 Untag...

Страница 159: ...ntagged MAC on port TX2 TX2 Adds VID 2 to packet TX1 VID 2 MAC on port TX2 TX2 Unicast Traffic TX1 VID 4 MAC on port TX2 Packet Discarded TX1 VID 2 Unknown MAC TX2 Floods VLAN 2 TX3 Untagged Unknown M...

Страница 160: ...VID 2 in the packet TX1 VID 4 MAC on port TX2 Packet Discarded TX1 VID 4 MAC on port TX3 Packet Discarded TX1 VID 2 MAC on port TX2 TX2 Strips VID off packet TX3 Untagged MAC on port TX6 TX6 Unicast T...

Страница 161: ...off packet Floods VLAN 4 TX2 Untagged MAC on port TX1 VID 2 TX1 Unicast Traffic TX2 Untagged MAC on port TX5 VID 2 TX5 Unicast Traffic TX2 VID 2 or 3 MAC on port TX5 VID 2 and 3 TX5 Strips VID off pac...

Страница 162: ...00 00 02 TX1 TX3 TX8 Goes to ports TX1 TX3 TX8 TX3 Untagged 01 00 00 00 00 01 TX2 TX4 TX8 Goes to ports TX2 TX4 TX8 TX6 Untagged 01 00 00 00 00 02 TX8 Goes to port TX8 TX3 Untagged 01 00 00 00 00 02 T...

Страница 163: ...C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 5 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration bulkhead mounting Shock 200g 10ms Vibration Seismic 50g 5 200...

Страница 164: ...er Optic Cable LX Fiber Optic Cable 100 Mb Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 80km TX Power Min 19dBm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength Mi...

Страница 165: ...ature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 5 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration bulkhead mounting Shock 50g 10ms Vibration Seismic 3...

Страница 166: ...er Optic Cable LX Fiber Optic Cable 100 Mb Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 80km TX Power Min 19dBm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength Mi...

Страница 167: ...nfiguration Switch 7506GX2 Switch Switches ______________________________________________________________________________________ Administration Administration SwitchName myname SwitchName optional 25...

Страница 168: ...o the maximum port number for the switch PVID 1 PVID PVID ranges from 1 to 4094 Port Port PortName TX6 PortName Name of port on switch PVID 26 PVID PVID ranges from 1 to 4094 Port Ports ______________...

Страница 169: ...delete mode must be keep or delete mode delete delete existing authorized MACs before adding authorized MACs default mode keep do not delete existing authorized MACs before adding authorized MACs Vali...

Страница 170: ...ce WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT...

Отзывы: