8
DIN-Rail Mounting
Install the unit in a standard 35mm Din-Rail. Recess the unit to allow
at least 3” of clearance for fiber optic cable bend radius, and 2 inches
for TX cables and power connections. Please note the 608MFX must
be installed in the vertical orientation for cooling purposes. In this
orientation, the power connector is at the top of the unit, and the signal
cables exit from the bottom of the unit.
19” Rack Mounting
19” Rack mount kits are available. Please consult with your local sales
representative for price & availability. Order part # 900RMK.
APPLYING POWER
1.
Unscrew the flange & Remove the DC Voltage Input Plug from
the Header.
2.
Install the DC Power Cables into the Plug(s) (observing polarity
per the legend on the top of the unit). L1+ and L2+ are the +24V
connections. M1 and M2 are the minus (-) returns for L1 and L2
respectively. F1 and F2 terminals are across the contact switch
that opens to signify a fault detection. Voltage/Current for F1/F2
is limited to 24V @ 100mA.
3.
Plug the Voltage Input Plug back into the side header. All LED’s
will flash ON Momentarily.
4.
The unit will complete the power up cycle in approximately 20
seconds.
Note:
Only 1 power supply must be connected to power for minimal
operation. For redundant power operation, L1 and L2 terminals must
be connected to separate DC Voltage sources. Use wire sizes 14-28
gauge.
Recommended 24V DC power supplies, similar to:
120/240VAC:
Sola SPDI –24-100
24VDC at 1.3A 0-60C
NTRON Part Number: SDP1