background image

(Revised 2011-07-13) 

  

 

 

 

 

 

 

 

 
 

 
 

500 Series 

Industrial  

Ethernet 

Switches 

 

 

 

       

Installation 

Guide 

 
 
 

 
 
 
 
 
 

 
 

 

Содержание 500 Series

Страница 1: ...Revised 2011 07 13 1 500 Series Industrial Ethernet Switches Installation Guide...

Страница 2: ...m Menu 23 N ViewTM Menu 23 Aging Menu 24 System Info 25 Restoring defaults 25 User Password 26 Switch Menu 27 Port Mirroring 27 MAC Based Trunking 29 QOS 31 VLAN 33 Tagged VLAN 34 Port VLAN 40 IGMP Sn...

Страница 3: ...Revised 2011 07 13 3 Damp Heat IEC60068 2 30 Test Db 66 GOST R Certified 66 Key Specifications 524TX 67 Damp Heat IEC60068 2 30 Test Db 68 GOST R Certified 68 Key Specifications 526FX2 FXE2 69...

Страница 4: ...S 517FX N XX S 526FX2 N XX S 508FXE2 N XX YY 509FXE N XX YY 517FXE N XX YY 526FXE2 N XX YY Where N N for N ViewTM A for Advanced Management Blank Otherwise XX ST or SC and YY 15 40 80 S Standard Tempe...

Страница 5: ...ncluded but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Warning Do not perform any services on the unit unless qualified to do so...

Страница 6: ...se to the unit Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty See the grounding technique section of this user manual for proper ways to groun...

Страница 7: ...his product must be UL listed for the area in which it is installed 5 Only UL listed wiring with temperature ratings greater than 90O C permitted for Class I Div 2 installations operating at temperatu...

Страница 8: ...e testing shall be considered 5 The end user shall provide bonding means as necessary All bonding equipment components shall be evaluated according to EN 60079 15 2005 and covered by a component certi...

Страница 9: ...iber links are capable of 2 Kilometers of 100 Mb communications without the use of repeaters The 509FXE 517FXE 526FXE is a 9 17 26 port switch that is similar to the 509FX 517FX 526FX but with extende...

Страница 10: ...hput Industry Standard 35mm DIN Rail Enclosure Optional N ViewTM Monitoring Optional Advanced Management Features Port Mirroring Mac Based Trunking Quality of Service traffic priority port or tagged V...

Страница 11: ...g the top cover will void the warranty DIN Rail Mounting Install the unit on a standard 35mm Din Rail Recess the unit to allow at least 5 of horizontal clearance for fiber optic cable bend radius 2 fo...

Страница 12: ...cated at the top or bottom of each connector The left LED indicates LINK status green for 100Mb link Orange for 10Mb link and the right LED indicates ACTIVITY Green for Full Duplex activity Orange for...

Страница 13: ...Foot All LED s will flash ON Momentarily Verify the Power LED stays ON GREEN Note Only 1 plug must be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be co...

Страница 14: ...ed PEM nut to connect a ground lug via a machine screw care should be taken to limit the penetration of the outer skin by less than 1 4 in Failure to do so may cause irreversible damage to the interna...

Страница 15: ...Revised 2011 07 13 15 RJ45 Connector Crimp Specifications Please reference the illustration below for your Cat5 cable specifications...

Страница 16: ...on com pdf nview_opc_user_guide pdf Once the software is installed you should view the Ports Counter page to remotely monitor each connected port You may find it helpful to copy Alt Print Screen the P...

Страница 17: ...ater for 100Mbit Operation 6 For FX FXE models verify TX is connected to far end RX and vise versa Also insure the connecting partner is 100Mb s IEEE 100BaseFX compliant Note the 500 Series FX FXE swi...

Страница 18: ...7 AF 00 05 26 N View is ENABLED Trunking Link Aggregation is DISABLED Mirroring is DISABLED Tagged QOS is DISABLED Port QOS is DISABLED VLAN is DISABLED IGMP Snooping is ENABLED Aging is ENABLED Manag...

Страница 19: ...sword enter password admin then press Enter see section on user defined password Example Managing IGMP Snooping Exit to return to Management Console Function Press ESC to Exit Now in user interface mo...

Страница 20: ...ig Configure Mirroring trunking Assign Port Trunking Groups info Get information about Trunking enable disable Enable Disable Trunking config Configure Trunking qos Quality of Service traffic priority...

Страница 21: ...cast Filter On 508FX2 A only o dis_nring Disable filters for N Ring or en_nring if currently disabled o dis_ring600 Disable filters for 600 series ring or en_ring600 if currently disabled ports Reconf...

Страница 22: ...version MAC address which functions are presently enabled SYSTEM Opens the SYSTEM menu The SYSTEM menu is used to set the system parameters SWITCH Opens the SWITCH menu You can make settings for the s...

Страница 23: ...switch status via the LAN When enabled periodic Multicast MAC packets are sent out from every port Note The configuration console is only available with A models Command Description Comment info Displ...

Страница 24: ...Comment info Displays the current Aging settings Default is 300 seconds except it is 20 seconds for 508FX2 and 526FX disable or enable Enable ro Disable Aging Choice is opposite of current state conf...

Страница 25: ...orts The Multicast addresses and group members are cleared After firmware version 8 09 the Router Multicast Data Filter is enabled on all ports Filtering Broadcast Filter is disabled All ports receive...

Страница 26: ...ycle is required when completed The user password feature is available in firmware version 8 09 and subsequent For security reasons forgotten passwords can only be reset to factory defaults with the p...

Страница 27: ...e choice is limited based on the source port Entries are ranged to prevent issues The destination port must be in the same group as the source port as below 1 through 8 and 25 9 through 16 17 through...

Страница 28: ...stination Port one of 1 2 3 4 6 7 8 25 Enter Port Number or ESC to exit 9 Select Destination Port one of 1 2 3 4 6 7 8 25 Enter Port Number or ESC to exit 8 For Port Mirroring the Destination Port is...

Страница 29: ...ir dynamically balances traffic and dynamically fails over If port 1 goes down ports 1 2 traffic is remapped to port 2 only If port 2 goes down ports 1 2 traffic is remapped to port 1 only If port 7 g...

Страница 30: ...runk Pair Port 2 Port 1 Trunk Pair Port 7 Port 8 Port 4 If 509FX A Fiber port 9 Port 5 Port 6 Port 3 Port 8 Port 2 Port 1 Port 4 If 509FX A Fiber port 9 Port 5 Port 6 Port 3 Port 2 508TX A or 509FX A...

Страница 31: ...ts have both QOS types disabled The A units have both QOS types disabled in default for version 7 08 and later firmware Tagged IEEE 802 1p Quality of Service QOS provides traffic priority based upon v...

Страница 32: ...6 CLI SWITCH QOS Example of the Port QOS config screen CLI SWITCH QOS set_port Configure Port QOS Select higher priority ports These ports are higher priority for Port QOS none Enter ports to enable...

Страница 33: ...tches one or more VLANs can be extended across a large network Notice that there is no change in Ethernet frames external to the switch with Port VLAN partitioning End stations are unaware of the VLAN...

Страница 34: ...work administrators must ensure ports with non 802 1Q compliant devices attached are configured to transmit untagged frames Many network interface cards for PCs and printers are not 802 1Q compliant I...

Страница 35: ...alue are denoted by parentheses as in YES Example of the Tagged VLAN config groupX screen taking default choices Note that for the defaults choices just enter all chosen ports have the group VID as th...

Страница 36: ...r YES CLI no Enter ports to have PVID 325 Example 3 6 12 14 enter Enter Port Numbers or ESC to exit 1 3 4 5 For incoming pkts with tagged VID 325 the outgoing pkts are untagged for ports 1 2 3 4 5 6 1...

Страница 37: ...tagged for ports 2 6 17 VLAN GROUP7 has VID 325 and includes Ports 1 2 3 4 5 6 17 GROUP7 outgoing pkts are untagged for ports 1 6 There is more Press SPACE BAR to continue or escape to exit For each p...

Страница 38: ...is Enabled CLI SWITCH VLAN group2 Configure Tagged VLAN Group 2 Enter VID or ESC to exit 4 Enter ports to Join VLAN Group 2 Example 3 6 12 14 enter Enter Port Numbers or ESC to exit 1 2 3 4 5 6 7 8 9...

Страница 39: ...GROUP2 outgoing pkts are untagged for ports 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 There is more Press SPACE BAR to continue or escape to exit For each port except port s 1 untagged incoming pkts wi...

Страница 40: ...ps they ll be added to group1 and you ll see a message Port VLAN Menu Command Description Comment info Displays the current VLAN settings disable or enable Enable ro Disable VLAN Choice is opposite of...

Страница 41: ...SWITCH VLAN info Port VLAN is ENABLED All outgoing frames will be untagged VLAN GROUP1 includes Ports 10 11 12 13 14 15 16 17 VLAN GROUP2 includes Ports 1 2 3 4 5 VLAN GROUP3 includes Ports 4 5 6 7 8...

Страница 42: ...ers or ESC to exit 4 5 Continued on next sheet CLI SWITCH VLAN port Wait Port VLAN selected CLI SWITCH VLAN enable Port VLAN is Enabled CLI SWITCH VLAN group2 Configure Port VLAN Group 2 Enter ports t...

Страница 43: ...GROUP1 includes Ports 10 11 12 13 14 15 16 17 VLAN GROUP2 includes Ports 1 2 3 4 5 VLAN GROUP3 includes Ports 4 5 6 7 8 9 VLAN GROUP4 includes Ports 1 2 3 4 5 6 7 8 9 VLAN GROUP5 includes Ports none V...

Страница 44: ...ly set and or automatically done Out of the box IGMP Snooping will function dynamically without intervention If some of the devices in the LAN do not understand IGMP then manual settings are provided...

Страница 45: ...s see below In firmware version 8 09 and subsequent the default is that the Router Multicast Data Filter is enabled for all ports so any router ports do not get DATA frames with KNOWN multicast destin...

Страница 46: ...ault Source IP Address is redundant to another in your topology and that this could create an issue in a device that is monitoring IGMP Queries AND mapping these Addresses to some other parameter In c...

Страница 47: ...n as router switch link ports One does not have to manually enter anything unless accommodating non IGMP devices Ports 4 and 5 were automatically detected as router switch link ports Rfilter was appli...

Страница 48: ...filter you will be asked to Enter ports that are to receive General Broadcast frames After entering sfilter you will be asked to enter the static multicast filter number 1 16 for 524 526 or static mul...

Страница 49: ...le the group or ESC to Exit CLI 01005e010100 Enter ports that are to receive on this multicast address Use commas to separate port numbers Example 3 6 12 14 22 enter Enter Port Numbers or ESC to exit...

Страница 50: ...enter anything for this purpose unless accommodating non IGMP devices 1 The entire 12 hexadecimal digits can be identified with a sniffer Or 2 The address can be calculated from a known class D addres...

Страница 51: ...of the low order 23 bits of the class D IP address to the low order bits of the MAC layer destination Mapping of class D 226 129 1 10 IP address to MAC layer multicast The mapping of 226 129 1 10 to...

Страница 52: ...d leave another in autonegotiate the default the unit in autonegotiation does not go into 10 full It goes into 10 half It gets no autonegotiation response It easily senses speed passively but has no w...

Страница 53: ...t numbers Example 3 6 12 14 22 enter Enter Port Numbers or ESC to exit 1 2 3 4 9 10 11 12 13 CLI SWITCH PORTS Example of the negotiate screen CLI SWITCH PORTS negotiate Enter ports that are to autoneg...

Страница 54: ...s Example 3 6 12 14 22 enter Enter Port Numbers or ESC to exit 1 7 19 CLI SWITCH PORTS Example of the Ports info screen CLI SWITCH PORTS info These ports are Enabled all ALL RJ45 ports are now set to...

Страница 55: ...d if the bottom layer is composed of simultaneously multicasting devices Reference the figure below 3 In stage 1 all ports of any 500 series A switch may be connected to multicasting devices NOTE A fi...

Страница 56: ...evices Reference the figure below 3 In stage 1 all ports of any 500 series A switch may be connected to multicasting devices NOTE A fiber ring backbone or trunked architecture is basically stage 1 for...

Страница 57: ...t 9 0 Amp 0 6 ms 24VDC Input Ripple Less than 100 mV Environmental Operating Temp 40oC to 85oC Storage Temp 40oC to 85oC Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Sh...

Страница 58: ...ss A FCC 47 CFR Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Low Frequency IEC60533 Shock IEE...

Страница 59: ...Operating 40oC to 85oC Storage Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration Shock 200g 10ms Vibration Seismic 50g 5 200Hz Triaxial Note Unit must be...

Страница 60: ...1000 6 4 EN55011 Class A FCC 47 CFR Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Low Frequenc...

Страница 61: ...erating 40oC to 85oC Storage Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration Shock 200g 10ms Vibration Seismic 50g 5 200Hz Triaxial Note Unit must be B...

Страница 62: ...1 EMI EN61000 6 4 EN55011 Class A FCC 47 CFR Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Lo...

Страница 63: ...7 0 Amp 0 8 ms 24VDC Input Ripple Less than 100 mV Environmental Operating Temp 40oC to 85oC Storage Temp 40oC to 85oC Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shoc...

Страница 64: ...ss A FCC 47 CFR Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Low Frequency IEC60533 Shock IEE...

Страница 65: ...ion 517FX 20oC to 70oC Operating 40oC to 85oC Storage Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration Shock 200g 10ms Vibration Seismic 50g 5 200Hz Tri...

Страница 66: ...1 EMI EN61000 6 4 EN55011 Class A FCC 47 CFR Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Lo...

Страница 67: ...current 1 0 A Inrush Current 9 5 Amp 0 75 ms 24VDC Input Ripple Less than 100 mV Environmental Operating Storage Temp 40oC to 85oC Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10...

Страница 68: ...7 CFR Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Low Frequency IEC60533 Shock IEEE 1613 250...

Страница 69: ...X2 20oC to 70oC Operating 40oC to 85oC Storage Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration Shock 200g 10ms Vibration Seismic 50g 5 200Hz Triaxial R...

Страница 70: ...000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Low Frequen...

Страница 71: ...RANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON...

Отзывы: