N-BIOTEK NB-101M Скачать руководство пользователя страница 11

www.n-biotek.com                                                                                                                                                   

N-BIOTEK

 

 

 

 

OM-NB-101M/101MT/101MC (Ver. 2009.07)                                                                                                                  11/13 

 

 

5. TROUBLE SHOOTING AND GUIDE

 

 

Service should be only performed by qualified service personnel   

Before replacing any electrical or mechanical components, disconnection unit from its 

electrical power source. If electrical power is required for service exercise extreme caution 

  as LINE VOLTAGE is present.   

 

1) Unit is not working (Check below before thinking this as malfunction) 

 

 

(1) Electrical connection   

Please disconnect main power cable and then reconnect.   

(2) Voltage supply   

  Please check to voltage.   

(3) Fuse check.   

(4) Verify voltage on unit.   

(5) Defective power switch (check voltage at switch) 

 

 

 

 

 

 

2) This message may be displayed as to 

 

- RPM is being set "0" or less than minimum RPM.   

- Something forced not to move when the platform is moving.   

- Solution : Use your hands to move platform and push "STOP" button simultaneously and 

  than push the "SET" button to increase RPM you want.   

 

 

 

 

3) This message may be displayed as to 

 

- Momentary noise symptom.   

- When the platform is being moved faster than RPM which you set.   

(This message may occur from 200 RPM)   

- Solution : These symptoms will be recovered automatically within 3 min or restart it.

 

 

Содержание NB-101M

Страница 1: ...ORBITAL SHAKER MODEL NB 101M 101MT 101MC OPERATING MANUAL...

Страница 2: ...able You have to use the product under specified electrical conditions If you use the product at the place in different power pressure it causes a fire and malfunction of the product Do not make the p...

Страница 3: ...tric shock and a fire 1 2 Precaution for installation Use it with the proper voltage Please check the voltage hertz written on serial label Over voltage low voltage can damage the product and poor per...

Страница 4: ...study result than the original purpose Do not use the product for different purpose It can cause malfunction or poor function Consequently you will get a wrong result Do not use an inflammable spray n...

Страница 5: ...u can get an electrocution when malfunction or an electric leakage occurs At the place where you can t ground Please buy the equipment to prevent any electrical leakage An electric shock an electric l...

Страница 6: ...netic induction drive Brush less DC motor provides less vibration and maintenance Artificial intelligence system which maintains precise speed adjust time LED indicates temperature speed time and stat...

Страница 7: ...TFORM CONTROL PANEL POWER S W 2 4 Control panel A B C D E F A DISPLAY For displaying RPM and TIME B RPM TIME Key for selecting RPM and TIME C SET Key for saving desired RPM and TIME D UP DOWN Key for...

Страница 8: ...or Start or Stop 3 Speed RPM Set up RPM and TIME are able to be set up when machine is in status of STOP If the instrument is on running please stop the instrument with pushing START STOP key 1 Press...

Страница 9: ...desired set point time At first you can set the hour using UP DOWN key and press SET key You can set the minute using UP DOWN key after set the hour Press SET key again after set time hour and minute...

Страница 10: ...ON NB 101MT NB 101MC 1 You can change shaking motion with moving conversion lever to another poll like below Reciprocating Orbital Motion MULTI SHAKER NB 101MT COMBINATION SHAKER NB 101MT In case of N...

Страница 11: ...main power cable and then reconnect 2 Voltage supply Please check to voltage 3 Fuse check 4 Verify voltage on unit 5 Defective power switch check voltage at switch 2 This message may be displayed as t...

Страница 12: ...E Setting Mode 5 This message may be displayed as to The electricity is on from power failure during TIME Momentary noise symptom When the platform is being moved faster than RPM which 5 This message...

Страница 13: ...f free warranty service for the faulty caused by user s improper operation excessive use use of incorrect voltage frequency storage in wrong environment mentioned in Manual 4 Complete the above table...

Отзывы: