NATIVE-C1
T
ECHNICAL
R
EFERENCE
M
ANUAL
V1.0
S
PECIFICATION AND
C
OMPLIANCES
- 39 -
5.2.
Environmental Specification
Table 21
–
Operating Temperatures
Condition
Temperature
Load
Storage Non-Operating
-45°C to +70°C
Cold Start
-20°C to -5°C
Any valid condition
Normal Operation
-5°C to 45°C
100%
Short Term Operation
45°C to 55°C
Linear derating to 80% at 55°C
Table 22
–
Other Environment
Criteria
Specification
Reference
Relative
Humidity
5% - 95%, non-condensing
GR-63-CORE, R4-7;
IEC 60068-2-56, 2-30
Table 23
–
Safety Grounds
Parameter
Characteristic
Power Module Safety Ground Resistance 10 m
Ω
Current Carrying Capacity
100 A
Contact Temperature Rise
<10 °C