MYTORQ MY-TR Скачать руководство пользователя страница 10

 

 

  Page  10  of  46

 

ELECTRIC 

SCREWDIVERS

 

 

Password change setting method

 

Click "Edit Settings" button → "Edit Password" to enter the old password and 

the new password, and then click OK button to complete the setting. 

NOTE: 

New password setting: Six to eight characters in length, including 

English uppercase and lowercase, numbers.

 

 

 

 

Restore default password

 

Select to enter the          Setting folder, delete the file named        Setup and 

Reopen it          Data_Acquisition_System can restore the default password 

(admin123) 

 

 

 

 

 

 

 

 

2

 

 

3

 

 

1

 

 

1

 

 

2

 

 

3

 

 

1

 

 

2

 

 

3

 

Содержание MY-TR

Страница 1: ...ELECTRIC SCREWDIVERS N DAS FOR MY TR System Operation Manual Y2F210 5 009 2022 01 26 ...

Страница 2: ...oduction 9 Unlock Settings 9 Password change setting method 10 Restore default password 10 1 Product setup page 11 2 Controller and Job setup page 28 3 Barcode Manager 32 4 Report and trend graph setup page 34 5 Instant data display 37 Remote Screen 38 System Function Setup 39 Info Company Website 41 Example Description 42 Statement 46 ...

Страница 3: ...describes how to quickly operate the Data Acquisition System and get started with the MY TR controller Diversified operation interface user friendly design also system can have functions such as report operation data analysis trend graph parameter setting etc ...

Страница 4: ...irements Windows 10 Windows 8 Windows 7 Windows XP or Windows Vista Hardware memory at least 768MB 2GBHz processor At least 2GB hard disk Recommended at least 16 bit color and 1024x768 screen resolution NET Framework 4 0 or above must be installed ...

Страница 5: ...d before operating this system MY TR Controller Executable file for the operating Data_Acquisition_System exe One RS 232 serial port One 1D Linear barcode scanner not necessary 2 Device connection as in the following diagram PC Barcode scanner PORT2 RS 232 RS 232 PORT1 MY TR ...

Страница 6: ...uter system as YYYY MM DD Step 2 Download the compressed software NOTE For the version 1 0 0 6 and later on there must have 2 additional dll files in the folder shown as below picture after you decompressed the software These are required files to run the software Step 3 Open the executable file Data_Acquisition_System exe ...

Страница 7: ...Page 7 of 46 ELECTRIC SCREWDIVERS Step 4 Move the mouse cursor to and display the four controllers Step 5 Controller selection MY TR ...

Страница 8: ...VERS Step 6 Go to Comm page port to pull down Connect according to the port of the computer display device And press and leave controller product testing setup page communication settings are default there is no need to modify A B ...

Страница 9: ...isplay after entering the screen At this time no operation can be performed due to locked setting You must enter the password first if need to unlock for operation Step 1 After clicking the button of Edit Settings the unlock window will pop up Step 2 Enter the default password admin123 and click confirm button 1 2 ...

Страница 10: ...sword and then click OK button to complete the setting NOTE New password setting Six to eight characters in length including English uppercase and lowercase numbers Restore default password Select to enter the Setting folder delete the file named Setup and Reopen it Data_Acquisition_System can restore the default password admin123 2 3 1 1 2 3 1 2 3 ...

Страница 11: ...oduct setup page divide the setup page into partitions and introduce them in order NOTE The pages of the system can be operated by sliding left and right so the software can be operated on the touch screen A H B H D H C H E H G H H H H H F H ...

Страница 12: ... the two zones from left to right in order Control Program Configuration Auto Learning Press and check the check box then the user could Load or Write the parameters When the check box is unchecked all input fields are shown as gray color which mean the user can t input any parameters A ...

Страница 13: ...own as white color which mean the user can input the parameters Program Display the program group currently used Program Tool ID Display the current used tool s id CLEAR Press to reset counting CONFIRM Press to dismiss controller C3 status refer to User Manual for C3 function introduction ...

Страница 14: ... the screwdriver to run RESET Press to restart the controller and restore factory parameters EDIT Press to enter screwdriver condition parameters COPY Press to copy the TQC condition parameter to Program Procedure tightening screws After done this procedure the system will copy T Q C data to HT HQ HC LT LQ LC as limitations ...

Страница 15: ...Page 15 of 46 ELECTRIC SCREWDIVERS LOAD To load the parameter settings from the MY TR controller Press and check and select program Press to finish this process 1 2 4 3 ...

Страница 16: ...Page 16 of 46 ELECTRIC SCREWDIVERS SAVE Save the parameters to MY TR controller Press and check then input required parameters Press and to finish this process 1 5 4 2 3 ...

Страница 17: ...Page 17 of 46 ELECTRIC SCREWDIVERS SELECT Press and check then input required parameters Press and to switch to required program QUIT Press to end after pressing 1 5 4 2 3 ...

Страница 18: ...e password to unlock the screen and switch to other pages Please refer to Password Change Setting Method Lock Settings Click to automatically jump to the Instant data display screen and no operation can be performed The lock settings must be unlocked Please refer to Instant data display Unlock Settings ...

Страница 19: ...splayed instantly Received Time The time to fasten the data Device ID Device ID 1 255 Program Unit This fastened program group Program Device Count The total number of times the device is fastened Sequence ID Shows current sequence unit ID 1 8 Screw Count The number of fastened units B ...

Страница 20: ...er of rotations at output shaft Shutoff Status shut off status OK NG OK ALL REV Device Mode STD mode ADV mode please refer to manual Device Status Refer to the Display Status Code Description in User Manual Barcode Data barcode data BarCodeEnable The C3 function will be dismissed when the barcode is scanned refer to User Manual for C3 function introduction ...

Страница 21: ...also the torque value is greater than 0 Scale 0 8 scale Shutoff Thread Output shaft must rotate more than displayed value or result will be ignored Point Clutch scale 1 15 OK Time Limit Set the maximum duration between each OK1 signal Once the time over this setting it will count 1 Count the number of times greater than OK interval OKALL Time Limit Set the maximum duration between each OKALL signa...

Страница 22: ...Page 22 of 46 ELECTRIC SCREWDIVERS TQC Range Analyze the average error value Program parameter setup refer to manual for condition parameters D E ...

Страница 23: ...Page 23 of 46 ELECTRIC SCREWDIVERS Program Load Write For the Load field please refer to ROAD For the Write field please refer to SAVE ...

Страница 24: ...Page 24 of 46 ELECTRIC SCREWDIVERS Max Count The field indicate program required total screw numbers Program parameter setup refer to Manual for Condition Parameters ...

Страница 25: ...in the Log Bar field at the bottom of the page Fasten data sheet TQC Trend Setting Fasten data sheet If you need to hide or display the received data please refer to Item selection Depress the scroll bar and swipe to the next page to display TQC Trend Setting Please refer to Trend Setting for the TQC setting F ...

Страница 26: ...Page 26 of 46 ELECTRIC SCREWDIVERS NOTE Touch the red box area and swipe to the next page to display a trend graph Main menu click to hide or display English title G ...

Страница 27: ... page by pressing button next page by pressing button NOTE Full description will be displayed when the mouse moves to the setting parameter please refer to manual for details Example When the mouse moves to SP SP Slow Start Speed Level is displayed H ...

Страница 28: ...Page 28 of 46 ELECTRIC SCREWDIVERS 2 Controller and Job setup page A B C ...

Страница 29: ...ng you can modify the controller status set by the device RED rectangle area After the setup is completed press the button and press to complete the query NOTE To query the Controller Configuration press NOTE Refer to instruction manual for device setup conditions A 3 4 1 2 ...

Страница 30: ...rs of filter time set to always enable filter function This setting not supports the BNK TOOL version before VER 2 16 All Sequences List Pick up a program from 1 99 programs the program could be set more than once setting 0 will be ignored and then execute the next unit Tightening cycle will follow the All Sequences List below After finish a cycle it will be repeated automatically To take below ca...

Страница 31: ...Page 31 of 46 ELECTRIC SCREWDIVERS Load All Sequences List Press to finish loading Setting All Sequences List Press setting Program Unit to finish setting 3 2 1 3 1 2 4 ...

Страница 32: ...Page 32 of 46 ELECTRIC SCREWDIVERS 3 Barcode Manager Set Read Barcode data to from MY TR NOTE Refer to the BARCODE LEARNING in MY TR User Manual A B A ...

Страница 33: ...AS s barcode function The procedure to set DAS s barcode data Step 1 Turn ON DAS s barcode function Step 2 Scan the barcode NOTE The data will be shown on the Barcode Data Step 3 You could input whole or partial barcode data in one of the Text Data and then assign this data to which Program No Step 4 Press NOTE and couldn t be used at the same time A B B ...

Страница 34: ...eed to clear it press the button to clear all the data immediately Historical Data File List Excel export When swiping the Controller Bar to page 4 press to export the Excel report to the specified location Excel import When swiping the Controller Bar to page 4 press and then click the Excel file to import it A B B H C H A H D H E H F ...

Страница 35: ... time point the form will be cleared to ensure sufficient memory space When is selected the data will be recorded in seconds as set in and the report will be exported below Trend Setting Time Torque Thread Select one of the Time Torque and Thread from the pull down menu It will show the graphic trend chart Refer to TQC Trend Setting NOTE When changing the Trend Setting T Q C setting the screen of ...

Страница 36: ...ger be received Item selection The selected items will affect the data recorded in the form When the item is checked the display data will be displayed otherwise it will not be displayed Example If you only want to display the received serial number torque and increase decrease from the tool check Receive Serial Number Torque increment decrease in Record selection E F ...

Страница 37: ... status of fasten process Program of Unit Indicate the current Program of the Unit Torque Display fastening torque Thread Display the number of turning screwdriver Screw of Count Display the number of current screw count status Time Display screw fastening time Barcode Display current Barcode data ...

Страница 38: ...Page 38 of 46 ELECTRIC SCREWDIVERS Remote Screen The screen image by remote monitoring NOTE Please contact with local distributors for the detail information ...

Страница 39: ...Page 39 of 46 ELECTRIC SCREWDIVERS System Function Setup Switch to Settings page to operate system functions ...

Страница 40: ... be changed 3 Initialwindow To set the initial windows setting 4 Background color system background color can be selected 5 Auto connection When switching the serial port COM will automatically connect to the device the next time you start the software 6 Output format Different formats for record storage can be select ...

Страница 41: ...Page 41 of 46 ELECTRIC SCREWDIVERS Info Company Website Info page to browse official website Switch to ...

Страница 42: ...always Tool1 When screws are fastened on 3 sides of a product the condition is as follows Job Unit Program Tool1 First Side Unit1 Program 1 Maximum count value 4 HQ 15 kgf cm LQ 1 kgf cm Tool 1 Second Side Unit2 Program 2 Maximum count value 3 HQ 20 kgf cm LQ 5 kgf cm Tool 1 Third Side Unit3 Program 3 Maximum count value 2 HQ 18 kgf cm LQ 3 kgf cm Tool 1 ...

Страница 43: ...que LQ 1 kgf cm and tool 1 2 Set to Unit 2 when the second side is fastened Program8 condition maximum count as 3 maximum fastening torque HQ 20 kgf cm minimum fastening torque LQ 5 kgf cm and tool 1 3 Set to Unit 3 when the third side is locked Program10 condition maximum count as 2 maximum fastening torque HQ 18 kgf cm minimum fastening torque LQ 3 kgf cm and tool 1 4 After complete setting para...

Страница 44: ...Page 44 of 46 ELECTRIC SCREWDIVERS Set condition parameter steps Program 5 Program 8 Program 10 settings are the same 1 5 4 2 3 ...

Страница 45: ...Page 45 of 46 ELECTRIC SCREWDIVERS Step 2 Press to modify the program Unit Press to then to store the parameters 4 3 2 1 ...

Страница 46: ... illegal activities Please acknowledge you have ownership for all your photos and texts Do not post or transmit any files that are defamatory insulting threatening offensive indecent defamatory false in violation of public order or good customs or other unlawful words pictures or files in any form nor infringe on the reputation or privacy of others business secrets trademarks copyrights patents ot...

Отзывы: