VAS525 VANQUISH™ FEATURES & SWITCH PLATE
1. Air intake cap
2. Latches
3. Air outlet
4. 25’ lighted power cord
5. Switch plate
6. Carrying handle
2
4
3
1
1. VARIABLE SPEED CONTROL KNOB
After plugging in the unit to a 115V outlet, the variable speed control knob
is used to turn on the unit and set the fan speed, which adjusts the CFM
from 250-500.
2. HEPA FILTER REPLACEMENT INDICATOR LIGHT
The indicator light illuminates when the HEPA filter exhibits 50% relative
reduction in capacity and airflow. The HEPA filter should be changed at this
point to resume efficient operation. Do not attempt to clean and re-use a
HEPA filter. Dust Pre-filters should be replaced after significant accumula-
tion of dust is clearly visible on surface. Make sure filters are placed in the
housing lid directionally as labeled on the filter itself.
3. CIRCUIT BREAKER
The circuit breaker turns off the unit when power running through the on-
unit circuit exceeds 12 amps.
4. AUXILIARY OUTLET
You can daisy-chain up to 2 additional Vanquish™ Air Scrubbers to
customize your setup for maximum air filtration. The unit conducts a
maximum of 12 amps when off and 9 amps when on.