background image

12

3 - Machine Maintenance

In order to keep the Mytee Lite™ running smoothly and 
reduce the risk of damage to the machine and subsequent 
downtime, Mytee recommends following the maintenance 
schedule below:

Maintenance Item

Daily

Weekly

Clean and inspect tanks.

X

Clean and inspect hoses.

X

Check and clean internal filters.

X

Check power supply cable.

X

Clean machine with all-purpose 
cleaner and cloth.

X

Check spray nozzles.

X

Flush solution system with Mytee 
System Maintainer.

X

Inspect vacuum hoses for holes and 
loose cuffs.

X

Inspect spray pattern for clogging. 
If clogged, remove spray tips and 
soak them in a recommended liquid 
neutralizer for up to six hours. To re-
move spray tip, twist spray tip body 
counter-clockwise.

X

Lubricate wheels with water resis-
tant oil.

X

Inspect machine for water leaks and 
loose hardware.

X

3.1 - Filter Maintenance

The Mytee Lite™ has a small filter on the top of the vac-
uum stack in the recovery tank. This filter should be 
checked and cleaned after each use. 

3.2 - System Maintainer

Regular flushing of the solution system with Mytee Sys-
tem Maintainer keeps your extractor running efficiently by 
removing hard water  scaling that builds up in the system.

How to use System Maintainer:

1.  Thoroughly mix System Maintainer with warm water at a 
1:1 ratio in a separate container. Pour into your Extractor’s 
solution tank.

2.  Connect a cleaning tool (upholstery tool, wand, etc.) and 
remove the jet(s) in order to prevent clogging from dis-
lodged mineral build-up.

3.  Turn on the Extractor’s pump and run the System Main-
tainer solution through the system and into a bucket or 
receptacle until you have a solid stream.

4.  Let sit for about 5 minutes while the System Maintainer 
solution does its job inside your Extractor.

5.  Finish running the rest of the solution through the sys-
tem.

6.  Run clean water through the system to flush out any 
remaining System Maintainer. 

Do not tamper with the set screw on the  
pump pressure switch. This can damage the 
pressure switch.

Содержание 8070 Lite

Страница 1: ...Mytee Lite Model 8070 REV 6 3 21 User Manual 13655 Stowe Dr Poway CA 92064 P 858 679 1191 F 858 726 6005 www mytee com...

Страница 2: ...use Neglecting your machine abusing it or not operating it properly can void its warranty and prevent the machine from performing to the quality and standard you d expect out of the Mytee line If you...

Страница 3: ...7 1 4 Mytee Lite Rear View 8 1 5 Switch Plate 9 Machine Operation 10 2 1 Powering the Mytee Lite 10 2 2 Connecting Hoses Cleaning Tools 10 2 3 Filling the Solution Tank 10 2 4 Operating the Mytee Lit...

Страница 4: ...g a plug this wire must be attached to only the grounding pin DO NOT use extension cords Please Note for America use only Parts and Service Please contact a Mytee service personnel or Mytee authorized...

Страница 5: ...be used as a toy Close attention is necessary when used by or near children 11 Do not use in areas where flammable or combustible material may be present 12 Do not leave the unit exposed to harsh wea...

Страница 6: ...I 120 Pump GPM 1 3 Heater 1 000 watt 210 F max Power Consumption 19 amps 115V Machine Weight 48 lbs Machine Dimensions With handle 33 x 12 x 36 5 Without handle 18 x 12 x 28 5 Power Cord Single 25 12...

Страница 7: ...Handle 2 Recovery Tank 3 10 Wheels 4 Quick Disconnect 5 Solution Tank Drain 6 Solution Tank 7 Faucet Fill Hose 8 Bucket Fill Opening 9 Cuff Lynx Hose Connection 10 Recovery Tank Lid 1 3 Mytee Lite Fro...

Страница 8: ...8 1 At a Glance 1 3 Locking Front Casters 2 25 12 3 Power Cord 3 Switch Plate 4 Opening Latch 5 Recovery Tank Drain Hose 6 Storage Basket 1 4 Mytee Lite Rear View 1 2 3 4 5 6...

Страница 9: ...9 1 At a Glance 1 5 Switch Plate 1 Vacuum Switch Activates the vacuum motor 2 Pump Switch Activates the solution pump 3 Heater Switch Activates the heater 1 2 3...

Страница 10: ...ck connect fitting on the base of the machine To connect pull back the flange on the female fitting from the hose and slide onto the male fitting on the machine Release to lock fittings together 2 3 F...

Страница 11: ...d e g while spraying with cleaning tool or right at startup If the pump is continuously running or pulsing there may be an issue with the pump pressure switch See the Troubleshooting section of this m...

Страница 12: ...of the vac uum stack in the recovery tank This filter should be checked and cleaned after each use 3 2 System Maintainer Regular flushing of the solution system with Mytee Sys tem Maintainer keeps yo...

Страница 13: ...13 4 Available Accessories 8400M Mytee Dry Upholstery Tool 8400 4 Stainless Steel Upholstery Tool 8700 Crevice Tool 8390EZ 10 Single Jet Carpet Cleaning Wand...

Страница 14: ...inlet port is cracked causing pump to suck in air Damaged pump switch housing Water is not pumping out of machine Vapor lock from turning on heater before pump Turn off the heater and allow the machin...

Страница 15: ...NOTES...

Страница 16: ...Mytee LLC 13655 Stowe Dr Poway CA 92064 www mytee com 2021 Mytee LLC Printed in the USA...

Отзывы: