4
7000S DRAIN VALVE AND SPOUT
When not using the Auto Pump-out, empty the tank by using the
drain valve on the front of the machine with the included drain
elbow (part # H226).
REVISIONS
REV.
DESCRIPTION
DATE
APPROVED
OD
ORIGINAL DRAFT
JFL
D
C
B
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
7000S
SHEET 1 OF 1
Flood Hog (2014)
OD
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:8
REV
DWG. NO.
C
SIZE
TITLE:
NAME
DATE
COMMENTS:
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
A
DO NOT
SCALE DRAWING
858-679-1191
mytee
PRODUCTS, INC.
V. LaBarbera
7000S WATER LEVEL CONTROL SWITCHES
As the water level reaches the pump-out water level control
switch, the pump is activated. Once the water level reaches the
vacuum water level control switch, the vaccum shuts off prevent-
ing the water from going into the vacuum stack, damaging the
vacuum motors. At the top of the vaccum stack, there is a filter.
Clean it weekly.
7000S FLOOD HOG™
REVISIONS
REV.
DESCRIPTION
DATE
APPROVED
OD
ORIGINAL DRAFT
JFL
D
C
B
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
7000S
SHEET 1 OF 1
Flood Hog (2014)
OD
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:8
REV
DWG. NO.
C
SIZE
TITLE:
NAME
DATE
COMMENTS:
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
A
DO NOT
SCALE DRAWING
858-679-1191
mytee
PRODUCTS, INC.
V. LaBarbera
Pump-out water
level control switch
Vacuum water level
control switch
Vacuum stack filter
REVISIONS
REV.
DESCRIPTION
DATE
APPROVED
OD
ORIGINAL DRAFT
JFL
D
C
B
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
7000S
SHEET 1 OF 1
Flood Hog (2014)
OD
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:8
REV
DWG. NO.
C
SIZE
TITLE:
NAME
DATE
COMMENTS:
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
A
DO NOT
SCALE DRAWING
858-679-1191
mytee
PRODUCTS, INC.
V. LaBarbera
REAR PLUGS
Two vacuum plugs are located in the back. The top and bottom rear plugs, depending on how they are capped, allow the Flood Hog™ to
be used as a stand-alone extractor, a flow-through booster connected to another machine, or an in-line pump-out unit. They also seal the
Flood Hog™ vacuum tank.
Cap both plugs
to use as a
flood extractor
Cap top plug to use as
a booster and pass-through
extractor.
See page 6.
Cap bottom plug
to use as booster
with pump-out
See page 6.