background image

1.0

General Information

03

2.0

Heating System Design

03

3.0

Unit Selection/Sizing

03

4.0

Location

03

5.0

Preparation

04

6.0

Fixing

04

7.0

Water Connections

05

8.0

Electrical Connection

06

9.0

Commissioning Procedure

07

10.0

Technical Data

08

11.0

Operating Instructions

09

12.0

Troubleshooting

10

13.0

Maintenance

11

Contents

21924 Slimline RC Manual - US:Layout 1  17/7/09  09:31  Page 3

Содержание SLIM-LINE RC

Страница 1: ...ating Maintenance and After Sales Manual Product Serial Number Please leave this manual with the end user Part Number 1371057 Issue 1 heatingthroughinnovation SLIM LINE RC 01 07 2009 ISSUE 1 Tested to...

Страница 2: ...t Selection Sizing 03 4 0 Location 03 5 0 Preparation 04 6 0 Fixing 04 7 0 Water Connections 05 8 0 Electrical Connection 06 9 0 Commissioning Procedure 07 10 0 Technical Data 08 11 0 Operating Instru...

Страница 3: ...means that 1 Care must be taken in sizing both the pump and piping 2 The minimum pipe size from boiler to fan convector must be at least 1 2 3 Where the unit is fitted on to a system with other emitte...

Страница 4: ...ole positions on the wall G Drill and plug the wall for No 8 x 11 2 round head wood screws ensuring that the wall plugs are suitable for the wall type G Remove the backing from the self adhesive washe...

Страница 5: ...leaks and vent the heat exchanger see Commissioning Procedure Note To ensure effective venting of the heat exchanger the flow pipe should be connected to the bottom connection of the heat exchanger No...

Страница 6: ...onnector G Connect supply to terminal block provided as per the wiring diagram below 8 0 Electrical Connection WARNING This appliance must be grounded The electrical installation must comply with stat...

Страница 7: ...set point can be adjusted using the set point switch located on the control board G Isolate electrical supply G Remove outer cover G Change switch position see fig 3 G Refit cover G Switch on electric...

Страница 8: ...tu h Entering Water Temperature F entering air temperature 65 F 1 3 186 127 97 186 127 97 Boost Medium Normal Boost Medium Normal 110 120 130 140 150 160 170 180 190 200 Heating Performance Data Air F...

Страница 9: ...e in the unit This means that air circulation can be provided in summer for example or that heating performance can be controlled manually The unit can be controlled using the infra red remote control...

Страница 10: ...re pressed the horizontal bars will reappear to show the key lock mode is activated however during this mode the handset controls remain functional To unlock the system press the On Off button for abo...

Страница 11: ...on Increase temperature set point Switch on at breaker Check all wiring and reset breaker Open valves Check boiler Programmer ON Boiler ON and set to high with central heating pump running Note Opera...

Страница 12: ...East Yorkshire HU9 5PE T 01482 713927 F 01482 789056 service convectors myson co uk Spare parts and technical help on all Convector products are available from MYSON Service MYSON INC 49 Hercules Dri...