KICKSPACE
®
Performance Data
Heat outputs tested in accordance with BS 4856 Part 1.
Flow Rate:
340 ltr/h (75 gal/h).
Flow Rate Correction Factors:
455 ltr/h (100 gal/h) multiply output by 1.03.
227 ltr/h (50 gal/h) multiply output by 0.96.
113 ltr/h (25 gal/h) multiply output by 0.85.
Duo (Hydronic/Electric) Heating Performance Data - Electric Mode
The unit will operate on either fan speed to provide 1kW of heating.
ltr/h
500
600
800
Floor
600-12V 500 Duo
500
600
800
Floor
600-12V 500 Duo
455
788
1046
911
448
1046
652
7.7
10.3
8.9
4.4
10.3
6.4
340
488
625
544
258
625
380
4.8
6.1
5.3
2.5
6.1
3.7
227
231
326
258
136
326
204
2.3
3.2
2.5
1.3
3.2
2.0
113
82
95
82
54
95
68
0.8
0.9
0.8
0.5
0.9
0.7
Approximate Hydraulic Resistance
1 8
KICKSPACE
®
Te c h n i c a l I n f o r m a t i o n
Model
40°
45°
50°
55°
60°
40°
45°
50°
55°
60°
500
Normal
733
815
896
976
1056
2501
2781
3057
3331
3603
Boost
923
1044
1166
1289
1412
3150
3564
3980
4397
4817
600
Normal
890
1048
1213
1384
1562
3036
3575
4138
4723
5329
Boost
1279
1451
1625
1800
1977
4363
4952
5545
6143
6744
800
Normal
1396
1552
1707
1860
2012
4763
5296
5824
6346
6864
Boost
1738
1964
2192
2420
2649
5930
6702
7478
8257
9039
Floor
Normal
622
711
802
894
987
2122
2427
2736
3049
3366
Boost
1035
1178
1322
1468
1615
3531
4018
4510
5008
5510
Heat Output (watts)
Heat Output (Btu/h)
Hydronic Heating Performance Data
Heat outputs tested in accordance with BS 4856 Part 1.
Hydronic Models
It is preferable to select the model with an output capable of
maintaining the calculated heat losses of the room when
operating at normal speed. This will enable the boost fan speed
and the higher temperature differences to be used to greater
advantage for rapid warming of the room from cold in excessive
conditions.
When establishing the temperature difference, i.e. mean water to
room temperature, allowance should be made for temperature
drop in the system. It is the water temperature at the convector
which dictates the output.
mm wg
kPa
Temperature Difference (°C)
Fan
Speed
Model
40°
45°
50°
55°
60°
40°
45°
50°
55°
60°
600 - 12V
Normal
890
1048
1213
1384
1562
3036
3575
4138
4723
5329
Boost
1279
1451
1625
1800
1977
4363
4952
5545
6143
6744
Heat Output (watts)
Heat Output (Btu/h)
Low Voltage Hydronic Heating Performance Data
Heat outputs tested in accordance with BS 4856 Part 1.
Temperature Difference (°C)
Fan
Speed
Model
40°
45°
50°
55°
60°
40°
45°
50°
55°
60°
500 Duo
Normal
636
734
835
938
1043
2169
2505
2849
3201
3560
Boost
835
958
1083
1210
1340
2849
3268
3696
4130
4571
Heat Output (watts)
Heat Output (Btu/h)
Duo (Hydronic/Electric) Heating Performance Data - Hydronic Mode
Temperature Difference (°C)
Fan
Speed